PUSHCORP AFD620 Adjustable Force Device Instructions

PUSHCORP AFD620 Adjustable Force Device Instructions

PUSHCORP-LOGO

PUSHCORP AFD620 justerbar kraftenhed

PUSHCORP-AFD620-Adjustable-Force-Device-PRODUCT

Brugsvejledning

FORSIGTIGHED: Active Force Devices contain calibrated electronics. HANDLE WITH CARE. DO NOT DROP.

BRUG IKKE SMØRET LUFT.

This device requires a dry, non-lubricated 80 psi (5.5 bar) maximum air supply filtered to 5 µm and a 0.3 micron oil mist separator. Non-compliance with these requirements will void the manufacturer’s warranty (See Section 3.4).

Kabelstyring

Alle elektriske kabler fra PushCorp, Inc. er klassificeret til robotapplikationer med høj vridning og fleksible egenskaber med en minimumsbøjningsradius på 125 mm (5 tommer). Kabelskader som følge af manglende overholdelse af denne specifikation dækkes ikke af garantien.

  • FORSIGTIGHED
    • Active Force Devices contain calibrated electronics. HANDLE WITH CARE. DO NOT DROP
  • BRUG IKKE SMØRET LUFT.
    • Denne enhed kræver en tør, ikke-smurt 80 psi (5.5 bar) maksimal lufttilførsel filtreret til 5 µm og en 0.3 mikron olietågeudskiller.
    • Manglende overholdelse af disse krav vil ugyldiggøre producentens garanti.
  • All fasteners, mounting holes, and pipe threads on this tool are METRIC
    • Alle elektriske kabler fra PushCorp, Inc. er klassificeret til robotapplikationer med høj vridning og fleksible egenskaber med en minimumsbøjningsradius på 125 mm (5 tommer). Kabelskader som følge af manglende overholdelse af denne specifikation dækkes ikke af garantien.

BEGRÆNSET GARANTI

Varighed

  • Et år fra leveringsdatoen til den oprindelige køber.

Who gives this warranty

  • PushCorp
  • Telefon: (972) 840-0208
  • Virksomhedens adresse:
  • Postboks 181915
  • Dallas, Texas 75218
  • Forsendelsesadresse:
  • 3001 W. Kingsley Rd.
  • Garland, Texas 75041

Who gives this warranty (purchaser)

  • Den oprindelige køber (bortset fra med henblik på videresalg) af PushCorp-produktet

What products are covered by this warranty

  • Any PushCorp industrial equipment or accessory supplied of manufactured by the Warrantor.

What is covered under this warranty

    • Defects in material and/or workmanship that occur within the duration of the warranty period

What is not covered in this warranty

  • IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
  • ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, or EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, MALFUNCTION OF THE PUSHCORP, INC. PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
  • Any failure that results from an accident, purchaser’s abuse, neglect, unauthorized repair, or failure to operate the products in accordance with the instructions provided in the owner’s manual(s) supplied with the product.

Responsibilities of the Warrantor under this warranty

  • Reparer eller udskift, efter garantigivers valg, produkter eller komponenter, der har svigtet inden for garantiperiodens varighed.

Responsibilities of the purchaser under this warranty

  • Deliver or ship the PushCorp, Inc. product or component to the PushCorp, Inc. Service Center, Dallas, TX. Freight and insurance costs, if any, must be borne by the purchaser.
  • Use reasonable care in the operation and maintenance of the product as described in the owner’s manual(s).

When the warrantor will perform repair or replacement under this warranty

  • Reparation eller udskiftning vil blive planlagt og serviceret i henhold til den normale arbejdsgang på servicecenteret og afhængigt af tilgængeligheden af ​​reservedele. Købere, der ønsker hurtigere reparation, kan modtage dette mod betaling af et forudbestemt ekspeditionsgebyr fra PushCorp, Inc.
  • Denne begrænsede garanti giver dig specifikke juridiske rettigheder, og du kan også have andre rettigheder, som varierer fra stat til stat.

OVERVIEW

  • The PushCorp, Inc. 620 Series Adjustable Force Device (US Patent No. 5,448,146) provides a superior force application system for robots and other automated equipment. The device can be placed in any position to enable a variety of manufacturing operations requiring a consistently applied force with 1.6 in. (40 mm) of compliant stroke. The AFD is designed to withstand continuous use in harsh industrial grinding, polishing, and drilling operations.
  • The 620 Series compliant tools utilize a pneumatic actuator to provide the force and provide closed-loop feedback. The 620 Series can apply up to a maximum 115 lbs. (512 N) of force. The AFD contains an accelerometer that monitors orientation and allows the unit to automatically compensate for gravitational and inertial effects. A linear potentiometer is also present within the AFD to sense the position of the Carriage.
  • The only external connection that is required to operate the 620 Series is a filtered, non-lubricated, 80 – 90 psi (5.5 – 6.2 bar) supply air provided through flexible tubing. An optional Purge Port is also provided for applications where great amounts of fine dust particles are created. The Purge Port connection provides additional airflow and internal positive pressure to help minimize the amount of contamination infiltrating the interior of the AFD. The AFD’s sliding Carriage has threaded mounting holes to provide easy process equipment attachment.
  • It is recommended that the user read the entire manual before beginning any operations to fully understand all the aspects and features of the 620 Series. All these features combine to make the PushCorp 620 Series Adjustable Force Device a rugged, state-of-the-art technology capable of providing reliable, precise, and consistent results in a variety of industrial applications.

HURTIG START

This section contains step-by-step instructions on how to quickly get the 620 Series Adjustable Force Device up and running for a quick test of its capabilities. Complete details on all the features are described in the sections that follow.

  1. Carefully unpack the 620 Series Force Device and verify that all parts indicated on the packing list are present and in good condition. If there is a problem, please notify the factory immediately so that corrective action may be promptly initiated.
  2. Step 2: Securely attach the 620 Series Mounting Bracket to the manipulator mounting flange or support table per Section 4.2.
  3. Step 3: Connect a dry, non-lubricated, 5 µm filtered 80 to 90 psi (5.5 to 6.9 bar) air supply to the 620 Series per Section 4.4.
  4. Trin 4: Se FCU-FLEX-manualen for oplysninger om elektriske forbindelser og softwareopsætning.

Læs venligst de følgende afsnit for at lære det fulde potentiale og funktionerne i PushCorp 620-seriens justerbare kraftenhed.

INSTALLATION

Montering af procesudstyr

  • The 620 Series Adjustable Force Device can accommodate many different types of process equipment. PushCorp provides a variety of standard process equipment, such as weld shavers, high-speed motors, plus other specialized tooling. Many end users also develop process equipment for their own applications. The AFD can be oriented parallel or perpendicular to the robotic manipulator mounting flange, although it is important to note that the AFD can apply force only in the direction of Carriage translation.
  • When mounting process equipment to the carriage, extreme care should be taken while designing and installing the brackets. Correctly designed brackets will increase the stiffness of the Carriage by becoming an external superstructure for the Carriage. The Carriage can gain a tremendous amount of rigidity if this approach is executed correctly. Incorrectly designed brackets will deform the Carriage surface, causing internal Linear Rail misalignment. A symptom of Carriage deformation is “slop” or “binding” of the Carriage. A deformed or loose Carriage will damage the Linear Guides and affect the consistency of your process. If the Carriage becomes loose or binds after installing the process equipment, then the brackets must be removed and the problem corrected. PushCorp, Inc. can design and fabricate brackets to user-supplied specifications as an option.PUSHCORP-AFD620-Adjustable-Force-Device-FIG (1)
  • The bolt pattern on the Carriage has been designed to facilitate process equipment installation. The Carriage has (14) fourteen M8x1.25 mounting holes with a depth of 0.51 inch (13 mm) to provide secure attachment points. The mounting holes are spaced 6.5 inches (165.1 mm) across and on 1 inch (25.4 mm) and 2 inch (50.8mm) centers along the length of the Carriage. (See Figure 1) The Carriage also has (2) four 5mm dowel pin holes to facilitate alignment. (See Figure 1 for location) These dowel pin holes are oversized to allow the pins to be glued into place using Loctite 609, or equivalent. Only utilize 4 of the M6x1 mounting holes; using more than 4 may cause warping of the carriage.
  • Care must be taken when designing and manufacturing brackets that will be mounted to the linear carriage. It is essential that these brackets maintain a face-to-face parallelism of at least 0.001” in order to prevent binding, which can lead to inaccurate applied force. As a result, we recommend using a tooling plate for the stock material or blanchard grinding the mounting faces.PUSHCORP-AFD620-Adjustable-Force-Device-FIG (2)
  • If these options are not practical for your design, machined steps or the use of shims under bolted surfaces are also suitable. We recommend a height of 0.02” to ensure enough clearance between the carriage and the mounting plate.PUSHCORP-AFD620-Adjustable-Force-Device-FIG (3)
  • ADVARSEL: DO NOT press pins into the AFD Carriage as this will likely damage the bearing Linear Guides.
  • FORSIGTIGHED: The Fastener Tightening Torque Specs chart in Section 6.0 should be used to determine proper fastener length and torque for fasteners into the Carriage. This is to prevent the pull-out of the Carriage helicoil inserts.

Mounting the AFD620 Series

  • The basic configuration of the 620 Series force device allows attachment to a stationary fixture or a robotic manipulator mounting flange. Specifying an AFD620 -1, -2, or -3 determines which Mounting Bracket is supplied. Adapter plates or “quick-change” attachments can be used as well for mounting. The 620 Series has (2) two 4mm dowel pins pressed into the base for location and alignment of the cover and Mounting Brackets.

Montering af AFD620-1 vertikal og AFD620-2 horisontal

  • The AFD620-1 and AFD620-2 are supplied with a standard Mounting Bracket with a 90 mm three-hole mounting pattern, see Figure 4. All three holes should be utilized to secure the Mounting Bracket to the robot mounting flange. If the Mounting Bracket is supplied blank or additional holes are required, it must first be removed from the device before drilling. Four cap screws are used to attach the Mounting Bracket to the 620 Series. Once the Mounting Bracket is removed, mounting holes may be placed anywhere within the crosshatched area shown in Figure 4. PushCorp, Inc. will supply engineering support to determine the mounting hole locations at no cost.
    Efter boring af det ønskede hulmønster fjernes eventuelle grater og eventuelle bearbejdningsrester fra monteringsbeslaget. Monteringsbeslaget kan derefter monteres igen.PUSHCORP-AFD620-Adjustable-Force-Device-FIG (4)

Maksimal vognbelastningsberegninger

  • The Linear Guide bearings that support the 620 Series sliding Carriage have been selected to provide optimal performance with respect to capacity, size, and low friction. To ensure continued optimal performance, it is very important not to overload these bearings. The following diagrams and associated equations are provided to check your application for excessive loading.
  • It is important to note that these equations require the use of Metric units. The necessary conversions are provided for your convenience. Insert your maximum applied force and process equipment weight (W) and overhang distances (D) to calculate an actual bearing load (L) that must be less than the maximum bearing load shown on the right side of the equation. The life of the bearings is 100,000 meters of linear motion, at the maximum allowable bearing load value. Exceeding this value (L) will reduce the life, and operating at less than this value (L) will increase the life. It is common to have combined weight and force loads on the Carriage. These situations may require adding two or more of the scenarios shown below. If your tooling is not similar to any of the designs listed here, or if the information is not clear, please contact PushCorp Technical Support for assistance.
  • Hvis AFD blev købt før januar 2023, henvises til dokumentet på: https://pushcorp.com/product/obsolete-products/ for passende beregninger af vognlast.
    • W = Maximum Force (N) (max. applied force + process equipment weight)
    • D = Load Overhang distance (mm) 1 lbf. = 4.45 N
    • Bearing Load (N) 1 in. = 25.4 mm
    • = Concentrated Load Position I N -0.102 kg
      PUSHCORP-AFD620-Adjustable-Force-Device-FIG (5)

Pneumatisk tilslutning

  • The 620 Series Adjustable Force Devices require a dry, non-lubricated, 5 µm filtered, 80 to 90 psi (5.5 – 6.2 bar) air supply. Failure to provide supply air to these specifications can degrade performance and will void any warranty repairs concerning pneumatic components. Filtered air is required since the high-speed servo spool valve used in the AFD cannot tolerate ANY foreign material in the supply air. Additionally, a minimum 80 psi (5.5 bar) air pressure must be maintained at the supply air port for the device to operate within published specifications. Operating at lower air pressure can cause inferior force control performance and possibly instability. Operating the AFD at pressures over 90 psi (6.2 bar) will activate a pressure relief valve inside the tool. This valve prevents damage to the internal load cell due to operating the tool with excessive pressure. This relief valve is strictly a protective mechanism and should not be used as a pressure regulator device.
  • The pneumatic supply system should be configured as shown in PUSHCORP-AFD620-Adjustable-Force-Device-FIG (6)
  • If water condensation is a problem in your air supply system, an air dryer device is highly recommended. The ideal solution is an industrial chiller dryer capable of reducing the dew point to less than 32° F (0°C). Moisture inside the force device will cause premature failure that will not be covered under warranty.
  • Under most circumstances, the standard internal purge will provide sufficient air to keep the 620 Series free of contaminants. In applications where the environment contains very small suspended particulate matter, additional purge air flow must be used to ensure that the AFD remains clear of foreign matter. An auxiliary Purge Port on the 620 Series (See Figure 6) provides a pneumatic connection to supply this additional air flow. The port accepts a metric R 1/8 tapered pneumatic fitting. PushCorp can provide fittings for English or metric tubing. The input pressure to the purge port can range from 10 PSI to 60 PSI (0.7 – 4.1 bar) with a flow rate of 0.5 to 2.0 SCFM (14 – 56 l/min) depending on theapplication. The purge air must be dry and non-lubricated; it needs only to be filtered to 20 microns. PUSHCORP-AFD620-Adjustable-Force-Device-FIG (7)
  • The Supply Line and Purge Line to the device should be 1/4 inch or 6mm diameter flexible polyurethane tubing. The tubing should be routed to the AFD such that there are no kinks and that there is plenty of slack to allow for manipulator motion. Before inserting the Supply Line into the force device air fitting, open the Shut-Off valve to blow out any contaminates which may be in the line. The tubing can now be pushed into the self-locking fitting located on the side of the AFD. Charge the Supply Line with compressed air and verify that there are no air leaks and that there is a minimum of 80 PSI (5.5 bar) at the AFD. If a minimum air pressure cannot be achieved, then an auxiliary air compressor or booster pump with at least 2 SCFM (56 l/min) must be installed.

NOTE:

  • PushCorp anbefaler stærkt brugen af ​​fleksible polyurethanslanger i modsætning til nylonslanger. Dette skyldes, at nylonslanger har en tendens til at klemme sammen, når de bøjes. Dette begrænser kraftigt luftstrømmen til AFD'en og forårsager ustabilitet.
  • To remove the Supply Line, first discharge all air pressure in the system, then while pushing inward on the fitting’s plastic ring, simultaneously pull the tubing out. Cover or plug the self-locking fitting anytime the Supply Line is not connected. This will keep any contaminants from entering the AFD.

Internt luftpatronfilter

The 620 Series contains a Cartridge Filter in the base housing. The Cartridge Filter is designed to be the last line of defense to protect the AFD from contamination. The Cartridge Filter is not designed to be the sole means of AFD supply air filtration. The pneumatic supply system must be configured as described in Section 4.4. If the filter becomes clogged, the 620 Series will not function properly. Replacement Cartridge Filters may be purchased from PushCorp (Part No. PAR01943-1) or from the manufacturer directly (Parker, Part No. 050-05-DQ). To remove the Cartridge Filter, loosen the Cartridge Filter Holder located on the side of the AFD base housing. See Figure 6. Remove the Cartridge Filter and perform a visual inspection. The condition of the Cartridge Filter will give an indication of the quality of your supply air system. Place a new Cartridge Filter on the Cartridge Filter Holder and insert it into the AFD base housing. Tighten the Cartridge Filter Holder to a torque of 11.6 lb-ft. (15.8 N-m).

ETHERNET GRÆNSEFLADE

  • AFD'en har en Ethernet-netværksforbindelse, der kan bruges til at konfigurere og kontrollere alle aspekter af værktøjet. Standard fabriksnetværkskonfigurationen er indstillet til:
  • IP-adresse: 192.168.0.10
  • Netværksmaske: 255.255.255.0
  • For at bruge Ethernet-forbindelsen i stedet for FCUFLEX-controlleren, skal et passende adapterkabel købes fra PushCorp for at give en standard Ethernet RJ45-netværksforbindelse. Strøm skal leveres til dette stik via en ekstern PASSIVE Power-Over-Ethernet (POE) injektor. POE-injektoren skal levere strøm til RJ45-stikket på ben 4,5: +24VDC, ben 7,8: -24VDC. Fabriksstandard-AFD-værtsnavnet er "AFD-xxxxx", hvor "xxxxx" er serienummeret på AFD-controlleren.

Console Command Interface

The Console Command Interface can be accessed via the USB serial interface or over Ethernet via a standard Telnet session (TCP Port 23). All commands are standard ASCII strings. Upon powering up, the following sign message is transmitted:

  • AFD Console Interface[CR][LF]
  • HW Version: 1.0 SW Version: 1.0[CR][LF] Build Date: Jan 01 2018, 00:00:00[CR][LF]revision.
  • This message is then followed by the command prompt: “>>”. This prompt follows all commands and indicates that the previous command is complete and that the unit is ready to accept additional commands.
  • Alle kommandoer skal være i følgende format:
  • Command [Arguments][LF]  where “Command” is a command mnemonic and “Arguments” is optional data representing any necessary arguments for the given command. Each character of the transmitted string is echoed back to the sender (including the terminating [LF]). This provides a mechanism to verify accurate data transmission.
  • Ved modtagelse af den afsluttende [LF] kan enheden reagere på en kommando på en af ​​tre mulige måder:
  1. A successful command with no returned data: Response String: OK[CR][LF]
  2. A successful command returning parameter data: Response String: Data[CR][LF]
  3. An unsuccessful command: Response String Error: Error Object [Error No]: Error Description[[CR][LF]

Det følgende afsnit beskriver de forskellige kommandoer til at styre og konfigurere AFD-controlleren.

Web og UDP Command Interface

  • AFD'en kan konfigureres og styres via web (TCP Port 80) and UDP (Port 1993) socket requests. For both of these interfaces, all returned data will be formatted as a JSON object.
  • The returned JSON object will always have two top-level keys: “status” and “data”. The “status” key will always have one of two values. A value of “success” indicates that the command was successful, and the “data” value will be either the requested parameter value or “OK” for commands that return nothing.
  • A “status” value of “fail” indicates that there was an error. In this case, the “data” key will contain a string describing the failure.
  • UDP-stik Example
  • En UDP-meddelelse med en ASCII (UTF-8) tekststreng, der indeholder den kommando, der skal udføres, skal sendes til port 1993 på AFD'en.
  1. Requesting a parameter Send string:
    1. /afd/commandForce
    2. Svarstreng:
    3. {“data”:{“/afd/commandForce”:12.0000},”status”:”succes”}
  2. Setting a parameter Send string: 
    1. /afd/enhedsnavn=fred
    2. Svarstreng:
    3. {“data”:{“/afd/deviceName”:”OK”},”status”:”success”}
  3. Command Failure Send string: 
    1. /afd/badCommand=24.2
    2. Svarstreng:
    3. {“data”:{“/afd/badCommand”:”Fejl: RpcObject[1]: Ukendt metode”},”status”:”fail”}

Web Anmod eksample

  • En anmodning kan sendes fra en web browser to the AFD with a URL streng, der indeholder kommandoen, der skal udføres.
  • Anmodning om en parameter
    • Send streng:
    • http://afd-00000/afd/commandForce
    • Svarstreng:
    • {"data":{"commandForce":12.0000},"status":"succes"}
  • Setting a parameter Send string: 
    • http://afd-00000/afd/deviceName=fred
    • Svarstreng:
    • {“data”:{“/afd/deviceName”:”OK”},”status”:”success”}

AFD Command Descriptions

  • The parameters and commands of the AFD are organized in a hierarchical directory tree structure to access various system components, as shown below: /afd (or “/”) /afd/net
  • The top-level or root is the initial working directory and allows access to the AFD top-level commands. The root directory can also be accessed either explicitly by “/afd” or by its default alias “/”.
  • A command or parameter can always be accessed by specifying its complete canonical name starting from the root. For example, to access the AFD’s Serial Number, the canonical command would be “/afd/serialNo”.

Selve parametrene og kommandoerne er beskrivende "Camel Case"-strenge (individuelle ord afgrænset med store bogstaver, f.eks. "camelCase") og starter med et lille bogstav. Kommandoen eller parameteren kan forkortes ved at bruge det første bogstav efterfulgt af hvert af de resterende store bogstaver. F.eksample, the “weighingInProgress” parameter is abbreviated “wip”. If there are no capital letters, then the entire parameter or command name must be used.

AFD Root Commands

Kommando Beskrivelse Datatype Læs/skriv
/afd/hjælp Viser alle tilgængelige kommandoer LISTE Læse
/afd/firmwareVersion Enhedens firmwareversion FLOAT Læse
/afd/hardwareVersion Enhedens hardwareversion FLOAT Læse
/afd/modelnavn Device model name (e.g., “AFD310”) SNOR Læse
/afd/serienummer Enhedens serienummer HELTAL Læse
/afd/metricUnits Metric or English units (0: English, 1: Metric) HELTAL Læs/skriv
/afd/maxForce Maximum force capacity FLOAT Læse
/afd/maxPosition Maksimal positionskapacitet FLOAT Læse
/afd/enhedsnavn User-assigned device name SNOR Læs/skriv
/afd/initialWeigh Enable/disable weigh payload on power-on (0: Disabled, 1: Enabled) HELTAL Læs/skriv
/afd/initialMode Sets initial power-on controlMode (0: Position Mode, 1: Force Mode, 3: Soft Touch Mode) HELTAL Read/Write
/afd/initialForce Sets the initial power-on command Force FLOAT Læs/skriv
/afd/initialPosition Sets the initial power-on command position FLOAT Læs/skriv
/afd/posLimitPosition Indstiller den positive positionsgrænse FLOAT Læs/skriv
/afd/negLimitPosition Indstiller den negative positionsgrænse FLOAT Læs/skriv
/afd/posLimit Position Limit status (-1: Neg Limit, 0: In Range, 1: Pos Limit) HELTAL Læse
/afd/softTouchEnabled Enable/disable Soft Touch feature (0: Disabled, 1: Enabled) HELTAL Læs/skriv
/afd/softTouchForce Set soft touch force as multiplier of commandForce (0.1 – 1.0) FLOAT Læs/skriv
/afd/softTouchPosition Set soft touch position as a multiplier of maxPosition (0.1 – 1.0) FLOAT Læs/skriv
/afd/softTouchActive Soft Touch feature is currently in effect (0: Inactive, 1: Active) HELTAL Læse
/afd/controlMode Sets basic mode of operation (0: Position Mode, 1: Force Mode, 3: Soft Touch Mode) HELTAL Læs/skriv
/afd/commandForce Sets the desired level of force when in Force Mode. May be positive or negative to push in either direction. FLOAT Læs/skriv
/afd/commandPosition Sets the desired carriage position when in Position Mode. Maybe only be a positive number (0.0: Fully negative, maxPosition: Fully positive) FLOAT Læse/Skrive
/afd/nyttelastVægt Sets the current payload weight. This parameter can be measured automatically by executing the weighPayload command. FLOAT Læs/skriv
Kommando Beskrivelse Datatype Læs/skriv
/afd/vejer Nyttelast Kommandoen starter den automatiske sekvens af måling af nyttelastvægt. N/A Læs/skriv
/afd/weighAtPosition This parameter returns whether the AFD tool is in the vertical position needed to execute the weighPayload command (0: Not in position, 1: In position) HELTAL Læse
/afd/vejningInProgress Returns whether the weighPayload sequence is in process (0: Not in progress, 1: In progress) HELTAL Læse
/afd/weightValid Indicates that the current payloadWeight status (0: Weight invalid, 1: Weight valid, -1: In process) HELTAL Læse
/afd/actualForce Returnerer den aktuelle målte påførte kraft FLOAT Læse
/afd/actualPosition Returnerer den aktuelle målte vognposition FLOAT Læse
/afd/accelGravity Returns the current measured Acceleration of Gravity in G’s (1.0: Vertical + downward, 0.0: Horizontal, -1.0: Vertical upward) FLOAT Læse
/afd/stateObject Return a JSON object representing the current device state JSON Læse
/afd/dumpCfg Dumps the current AFD user configuration LISTE Læse
/afd/saveConfig Save the current FCUFLEX user configuration to non-volatile FLASH memory INGEN Skrive

AFD Network Commands

Kommando Beskrivelse Datatype Læs/skriv
/net/hjælp Viser alle tilgængelige kommandoer LISTE Læse
/net/værtsnavn Netværksværtsnavn SNOR Læs/skriv
/net/dhcp Set to use the DHCP server to obtain an IP address (0: Static IP, 1: DHCP) HELTAL Læs/skriv
/net/timeout Timeout for DHCP-server (sekunder) INTEGER Læs/skriv
/net/ip-adresse Returns the currently assigned IP address SNOR Read
/net/gateway Returns the currently assigned network gateway IP address SNOR Læse
/net/netMask Returns the currently assigned network mask SNOR Læse
/net/macAddress Returnerer Ethernet hardware (MAC) adresse SNOR Læse
/net/linkStatus Returns link status of Ethernet interface (0: Disconnected, 1: Waiting for IP address, 2: Connected) HELTAL Read

TEKNISKE SPECIFIKATIONER

Kategori Specifikation
Maximum Applied Force 115 lbs. (511 N)
Maksimal nyttelast 115 lbs. (52.2 kg)
Vægt AFD620-1: 39 lbs. (17.7 kg); AFD620-2: 27 lbs. (12.2 kg); AFD620-3: 27 lbs. (12.2 kg)
Compliant Stroke 1.6 tommer (40 mm)
Force Accuracy ±0.4 lb (±2.0 N)
Temperatur 50° til 122° F (10° til 50° C)
Fugtighed 5% til 95%, ikke-kondenserende
Tilluft Non-lubricated, Dry, 5μm Filtered, 80-90 psi (5.5-6.2 bar), 2 SCFM (56 l/min)

Specifikationer kan ændres uden varsel.

Befæstelsesstørrelse Torque (In.-lbs.) Torque (ft.-lbs.) Moment (N·m) Minimum Depth (in.) Minimum Depth (mm)
M4 x 7 50 4.2 5.6 0.17 4.3
M5 x 8 85 7.1 9.6 0.21 5.3
M6 x 1 140 11.7 15.8 0.25 6.3
M8 x 1.25 348 29.0 39.3 0.33 8.4
M10 x 1.5 600 50.0 67.8 0.41 10.5

FOREBYGGENDE VEDLIGEHOLDELSESPLAN

It is highly recommended to adhere to the preventative maintenance schedule in order to help extend the longevity of the specified PushCorp, Inc. equipment. Failing to do so could cause a loss in functionality as well as a decrease in product life.

Vedligeholdelsesopgave Ugentlig Månedlig 3 måneder 6 måneder
Fjern snavs fra AFD X
Kontroller, at stikkene ikke er bøjet/beskadiget X
Kontroller, om slæden bevæger sig let frem og tilbage X
Measure the supply and purge lines at the tool for the recommended pressure/flow and ensure no losses in the pneumatic supply X
Kontroller filtrene for forurening – udskift dem, hvis de er mørkegule/brune X
Udskift filterpatron(er) X

Agentur/organisation:________________________________________________
Afsluttelsesdato:_____________________________________________________

Fejlfinding

Specific troubleshooting steps are not detailed in the provided text. However, the following general advice applies:

  • Bortfald af garanti: Non-compliance with air supply requirements (dry, non-lubricated, filtered 80 psi max, 0.3 micron oil mist separator) will void the manufacturer’s warranty.
  • Kabelskade: Cable damage due to exceeding the minimum bending radius (125mm / 5 in) will not be covered under warranty.
  • Generelle fejlfunktioner: For issues not related to air supply or cable damage, refer to the full owner’s manual or contact PushCorp, Inc. for support.

Dokumenter/ressourcer

PDF thumbnailAFD620 Justerbar kraftenhed
Instructions · AFD620, AFD620 Adjustable Force Device, AFD620, Adjustable Force Device, Force Device, Device

Referencer

Stil et spørgsmål

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Stil et spørgsmål

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.