VEVOR 15PBG-6A

VEVOR Hot Water Recirculating Pump (Model 15PBG-6A)

Instruktionsmanual

1. Introduktion

The VEVOR Hot Water Recirculating Pump is designed to provide instant hot water to your faucets and showers, eliminating the wait for hot water and reducing water waste. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your pump.

Woman enjoying instant hot water from a shower, with a VEVOR recirculating pump diagram showing cold water entering and hot water exiting.

Image: The VEVOR Hot Water Recirculating Pump ensures instant hot water delivery, reducing wait times and water waste.

2. Sikkerhedsinstruktioner

Please read and understand all safety instructions before installing or operating the pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

  • Always disconnect power to the water heater and pump before performing any installation, maintenance, or service.
  • Sørg for, at pumpen er korrekt jordforbundet for at forhindre elektrisk stød.
  • Brug ikke pumpen, hvis netledningen eller stikket er beskadiget.
  • Installation should be performed by a qualified plumber or electrician in accordance with all local codes and regulations.
  • Brug passende personlige værnemidler (PPE), såsom sikkerhedsbriller og handsker, under installation og vedligeholdelse.
  • This pump is designed for hot water circulation only. Do not use with flammable, corrosive, or hazardous liquids.
  • Ensure adequate ventilation around the pump and water heater.
  • Hold børn og uautoriserede personer væk fra installationsområdet.

3. Produktet er slutview

Nøglefunktioner

  • Øjeblikkeligt varmt vand: Delivers hot water quickly with a maximum flow rate of 10.0 GPM and a 21.6 ft head lift, reducing water waste.
  • 3-hastighedskontrol: Adjustable settings (99W/67W/44W) for varying flow rates (2.13/1.69/1.21 m³/h) to balance performance and energy savings.
  • Alsidige applikationer: Compatible with various home water systems including floor heating, boilers, solar and electric water heaters, kitchen faucets, radiators, washing machines, and toilets.
  • Holdbar konstruktion: Features a robust cast iron pump head for long-term reliability and resistance to damage.
  • Nem installation: Designed for direct mounting at the outlet of indoor tank water heaters without requiring pipe modifications. Not suitable for tankless systems.
Kitchen and bathroom scenes illustrating the pump's ability to save energy and water throughout the home.

Image: The recirculating pump provides hot water efficiently for various household uses, saving energy and water.

Komponenter

The VEVOR Hot Water Recirculating Pump package includes:

  • 1 x Hot Water Recirculating Pump (Model 15PBG-6A)
  • 1 x Set of Inlet/Outlet Adapter (NPT 3/4 in to NPT 1/2 in)
  • 2 x Sealing Gaskets
  • 1 x brugermanual
  • 1 x PTFE-tape
Close-up of the VEVOR pump's cast iron head, highlighting its sturdy, heat-resistant, and deformation-proof qualities.

Image: The pump features a durable cast iron head, ensuring long-lasting performance.

4. Specifikationer

SpecifikationVærdi
Varemodelnummer15PBG-6A
Voltage & FrekvensAC 110-120V 60Hz
Maksimal flowhastighed10 GPM (38 l / min)
Maksimal hovedløft21.6 fod / 6 m
Nominel effekt0.13 HP (99W max)
Indgang / udgangsstørrelseNPT 3/4 in (with NPT 3/4 in to NPT 1/2 in adapter)
Vandtæt vurderingIPX8
Anbefalet installationAt the Water Heater Outlet
FarveOrange + Sort
PumpehovedmaterialeStøbejern
Nettovægt4.78 lbs / 2.17 kg
Produktdimensioner5.31 x 5.12 x 5.31 tommer (135 x 130 x 135 mm)
Diagram showing the dimensions of the VEVOR Hot Water Recirculating Pump in inches and millimeters, along with a table of key specifications.

Image: Detailed dimensions and technical specifications of the pump.

Nærbillede view of the VEVOR Hot Water Circulator Pump's label, displaying model number 15PBG-6A, voltage, power, and maximum flow/head lift.

Image: Product label showing model and electrical specifications.

5. Opsætning og installation

The VEVOR Hot Water Recirculating Pump is designed for easy installation at the hot water outlet of indoor tank water heaters. It is ikke suitable for tankless water heater systems.

Før installation

  • Ensure the water heater is turned off and the power supply is disconnected.
  • Close the main water supply valve to your home.
  • Drain a small amount of hot water from a nearby faucet to relieve pressure in the hot water line.
  • Gather necessary tools: pipe wrench, adjustable wrench, PTFE tape, bucket, and towels.

Installationstrin

  1. Identify Hot Water Outlet: Locate the hot water outlet pipe on your indoor tank water heater.
  2. Disconnect Pipe: Carefully disconnect the hot water outlet pipe from the water heater. Be prepared for residual water.
  3. Forbered forbindelser: Apply PTFE tape to the threads of the pump's inlet and outlet, as well as the included NPT 3/4 in to NPT 1/2 in adapters.
  4. Install Adapters: Attach the appropriate adapters to the pump's inlet and outlet, ensuring the sealing gaskets are properly seated.
  5. Monter pumpe: Connect the pump directly to the hot water outlet of the water heater. Ensure the flow direction arrow on the pump aligns with the direction of hot water flow out of the heater.
  6. Gentilslutning af rør: Reconnect the household hot water piping to the pump's outlet.
  7. Secure Electrical: Connect the pump's power cord to a grounded electrical outlet. Ensure all electrical connections are secure and meet local codes.
  8. Genopret vandforsyningen: Slowly open the main water supply valve and check all connections for leaks.
  9. Udluft luft: Open a hot water faucet in your home to allow air to escape the system until a steady stream of water flows.
  10. Gendan strøm: Once all connections are secure and leak-free, restore power to the water heater and pump.
Diagram illustrating the installation of the VEVOR recirculating pump with threaded adapters and sealing gaskets, showing its connection to a water heater and shower system.

Image: Installation diagram showing pump connection to a water heater and pipe system.

6. Betjeningsvejledning

The VEVOR Hot Water Recirculating Pump features a convenient 3-speed control, allowing you to adjust the flow rate and power consumption according to your needs.

3-hastighedskontrol

Use the switch located on the pump's control box to select one of the three available speeds:

  • Speed 1 (Low Flow): 44W power consumption, 1.21 m³/h flow rate. Ideal for minimal hot water demand or energy saving.
  • Speed 2 (Medium Flow): 67W power consumption, 1.69 m³/h flow rate. Suitable for moderate hot water usage.
  • Speed 3 (High Flow): 99W power consumption, 2.13 m³/h flow rate. Provides maximum hot water circulation for high demand.

Select the speed that best matches your household's hot water requirements and desired energy efficiency.

Image showing the VEVOR recirculating pump with three speed settings (44W, 67W, 99W) and corresponding flow rates, illustrating its adaptability for different hot water needs like morning wash, noon dishwashing, and evening shower.

Image: The 3-speed control allows adjustment of hot water flow for various needs.

7. Vedligeholdelse

Regular maintenance ensures optimal performance and extends the lifespan of your VEVOR Hot Water Recirculating Pump.

  • Undersøg for utætheder: Periodically check all connections for any signs of water leaks. Tighten connections or replace gaskets as needed.
  • Hold rent: Ensure the pump and surrounding area are kept clean and free from dust or debris that could obstruct ventilation.
  • Elektriske forbindelser: Regularly inspect the power cord and electrical connections for any signs of wear or damage.
  • Mineralopbygning: In areas with hard water, consider periodic flushing or descaling of your hot water system to prevent mineral buildup that could affect pump efficiency.
  • Vinterisering: If the pump will be idle for extended periods, especially in freezing temperatures, drain the system completely to prevent damage from freezing water.

8. Fejlfinding

Se tabellen nedenfor for almindelige problemer og deres mulige løsninger.

SpørgsmålMulig årsag og løsning
Pumpen starter ikkeIngen kraft: Check power supply, circuit breaker, and electrical connections. Ensure pump is plugged in.
Motor seized: Contact VEVOR support or a qualified technician.
Low or no hot water flowIncorrect speed setting: Adjust to a higher speed (Speed 3 for maximum flow).
Luft i systemet: Bleed air from the hot water lines by opening a hot water faucet.
Blokering: Check pipes and pump for obstructions or mineral buildup.
Pumpen larmerLuft i systemet: Bleed air from the hot water lines.
Løs montering: Ensure the pump is securely mounted and connections are tight.
Internt problem: Contact VEVOR support or a qualified technician.
Vandlækage fra tilslutningerLøse forbindelser: Tighten all threaded connections.
Damaged gaskets/PTFE tape: Replace sealing gaskets or reapply PTFE tape.
Pumpen kører kontinuerligtThis pump model does not have a built-in timer. It will run continuously when powered on. If you require timed operation, an external timer can be used.

If you encounter issues not listed here or if solutions do not resolve the problem, please contact VEVOR support or a qualified technician.

9. Garanti og support

For detailed warranty information, technical assistance, or to inquire about replacement parts, please visit the official VEVOR Support Center.

VEVOR Supportcenter: www.vevor.com/support

Producentens adresse: Sanyen Technology Ltd., Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730

10. Bortskaffelse

When the VEVOR Hot Water Recirculating Pump reaches the end of its service life, please dispose of it responsibly according to local environmental regulations for electronic waste. Do not dispose of the product with general household waste.