1. Introduktion

This instruction manual provides essential information for the safe and proper operation of your KAIWEETS HT100s-R Non-Contact Voltage Tester and KAIWEETS KT301T GFCI Outlet Tester. Please read this manual thoroughly before use and retain it for future reference. These devices are designed to assist in electrical testing and ensure safety in various applications.

2. Sikkerhedsoplysninger

Always prioritize safety when working with electricity. Follow all local electrical codes and safety regulations. Do not use the testers if they appear damaged or are not functioning correctly. Always wear appropriate personal protective equipment (PPE).

3. KAIWEETS HT100s-R Non-Contact Voltage tester

3.1 Produktegenskaber

3.2 Setup and Battery Installation

The HT100s-R requires 2 AAA batteries (included). To install or replace batteries:

  1. Twist the tail cap counter-clockwise to open the battery compartment.
  2. Isæt to AAA-batterier, og overhold den korrekte polaritet (+/-).
  3. Replace the tail cap and twist clockwise to secure it.

3.3 Betjeningsvejledning

3.3.1 Tænd/sluk

Tryk på tænd / sluk-knappen () to turn the device on. Press and hold the power button to turn it off. The device will automatically power off after a period of inactivity to conserve battery.

3.3.2 Non-Contact Voltage (NCV) Detektion

Place the tip of the tester near the conductor, outlet, or wire you wish to test. If AC voltage is detected, the tip will glow red, and an audible beep will sound. The frequency of the beeps and the percentage value on the screen will increase with higher voltage eller tættere på kilden.

KAIWEETS HT100s-R Non-Contact Voltage Tester detekterer volumentage in an electrical outlet.

Image: The HT100s-R tester being used to detect voltage in an electrical outlet. The tip glows red, indicating voltage tilstedeværelse.

3.3.3 Følsomhedsjustering

The HT100s-R features two sensitivity modes:

The screen color indicates voltage niveau: Rød for høj voltage/live wire, Grøn for lav voltage/null wire.

KAIWEETS HT100s-R showing high and low sensitivity modes for null and live wire detection.

Image: Illustrations demonstrating the HT100s-R in both high and low sensitivity modes, indicating detection of null and live wires with corresponding visual and audible feedback.

3.3.4 Breakpoint-test

To perform a breakpoint test, move the tester along an insulated wire. The tester will indicate the presence of voltage up to the point of the break, helping to locate faults in cables.

KAIWEETS HT100s-R performing a breakpoint test on an insulated cable.

Image: The HT100s-R being used to perform a breakpoint test on an insulated electrical cable, illustrating its ability to detect breaks.

3.3.5 LED lommelygte

Tryk på lommelygteknappen (💡) to turn on the integrated LED flashlight. This feature is useful for illuminating dimly lit work areas.

KAIWEETS HT100s-R with its LED flashlight illuminated in a dark electrical panel.

Image: The HT100s-R's bright LED flashlight illuminating a dark electrical panel, demonstrating its utility in low-light conditions.

4. KAIWEETS KT301T HFI-stikkontakttester

4.1 Produktegenskaber

KAIWEETS KT301T GFCI Outlet Tester displaying its features and design.

Billede: En overview of the KAIWEETS KT301T GFCI Outlet Tester, highlighting its key features such as auto-hold, GFCI testing, LCD display, and low battery alert.

4.2 Setup and Battery Installation

The KT301T requires 2 AAA batteries (included). To install or replace batteries, open the battery compartment located on the back of the device, insert the batteries with correct polarity, and close the compartment securely.

4.3 Betjeningsvejledning

4.3.1 Standard Outlet Testing

Plug the KT301T directly into a standard 3-prong outlet. The LCD display will immediately show the real-time voltage and the wiring condition. The bottom indicator lights will also provide a quick visual status (e.g., green for correct, orange for faults).

KAIWEETS KT301T testing both a standard outlet and a GFCI outlet.

Image: The KT301T in use, demonstrating its capability to test both standard electrical outlets and GFCI outlets, displaying voltage og ledningsstatus.

4.3.2 GFCI Outlet Testing

After plugging the KT301T into a GFCI outlet and observing the initial wiring status, press the PRØVE button. A correctly functioning GFCI outlet should trip, cutting power to the outlet. Press the NULSTIL button on the GFCI outlet to restore power. If the GFCI does not trip, it indicates a fault.

4.3.3 LCD-display og indikatorer

The 1.8-inch backlit LCD color screen provides clear readings of voltage and wiring status. Green indicates correct wiring, while orange indicates a fault. The bottom indicator lights offer additional visual cues, especially in dark environments.

KAIWEETS KT301T's backlit LCD color screen displaying voltage og ledningsstatus.

Image: A close-up of the KT301T's 1.8-inch backlit LCD color screen, showing a clear display of voltage and correct wiring status, suitable for various lighting conditions.

4.3.4 Auto-Hold Data

The auto-hold function captures and locks the test results on the screen for 5 minutes, allowing for easy viewing even in hard-to-reach locations or after removing the tester from the outlet.

KAIWEETS KT301T demonstrating the hands-free data hold function.

Image: The KT301T demonstrating its hands-free data hold feature, which locks the reading on the screen for convenient viewing after testing an outlet.

5. Vedligeholdelse

6. Fejlfinding

ProblemMulig årsagLøsning
Enheden tænder ikke.Døde eller forkert installerede batterier.Udskift batterierne, og sørg for korrekt polaritet.
HT100s-R gives inconsistent readings.Interference from nearby electrical fields; incorrect sensitivity mode.Move away from other electrical devices; switch to low sensitivity mode if appropriate.
KT301T shows a fault, but outlet seems to work.Hidden wiring fault (e.g., open ground, open neutral, reverse polarity).Kontakt en kvalificeret elektriker for at få inspiceret ledningerne.
KT301T GFCI test does not trip.Defekt HFI-stikkontakt eller forkert ledningsføring.Do not use the outlet. Have a qualified electrician inspect and repair/replace the GFCI outlet.

7. Specifikationer

7.1 KAIWEETS HT100s-R Non-Contact Voltage tester

7.2 KAIWEETS KT301T GFCI Outlet Tester

8. Garanti og kundesupport

KAIWEETS tilbyder en 3 års garanti for these products. If you encounter any issues or have questions regarding the operation, maintenance, or troubleshooting of your HT100s-R Voltage Tester or KT301T GFCI Outlet Tester, please contact KAIWEETS customer support for professional assistance.

For support, visit the official KAIWEETS webwebstedet eller se de kontaktoplysninger, der følger med din produktemballage.

Relaterede dokumenter - HT100s-R, KT301T

Preview KAIWEETS KT301P Digital Afbryderfinder Brugermanual
Brugermanual til KAIWEETS KT301P digital afbryderfinder, der beskriver dens funktioner, anvendelse og specifikationer til identifikation af afbrydere og test af ledningsforhold.
Preview Kaiweets KM117B stikkontakttester Instruktioner og sikkerhedsvejledning
Omfattende guide til Kaiweets KM117B stikkontakttester, der beskriver dens funktioner til detektering af ledningsproblemer, GFCI-testning og voluminøsitet.tage-målinger. Indeholder sikkerhedsadvarsler og tekniske specifikationer.
Preview KAIWEETS KT301P Digital Afbryderfinder Brugermanual
Brugermanual til KAIWEETS KT301P digital afbryderfinder, med detaljerede oplysninger om funktioner, sikkerhedsadvarsler, betjeningsvejledninger og brug af tilbehør til lokalisering af afbrydere og test af ledningsforhold.
Preview KAIWEETS VT200 Kontaktløs volumentage-testerens betjeningsmanual
Officiel betjeningsmanual til KAIWEETS VT200 berøringsfri volumentage-tester, der giver detaljerede instruktioner om brug, sikkerhedsfunktioner, produktoversigtview, tekniske specifikationer og vedligeholdelse.
Preview VT200 Kontaktløs volumentage Brugervejledning til detektor
Brugermanual til Kaiweets VT200 berøringsfri volumentage-detektor, der dækker sikkerhedsforanstaltninger, produkt overview, betjening, batteriudskiftning og generelle specifikationer.
Preview KAIWEETS ST120 Smart Pen-type multimeter brugermanual
Denne manual indeholder detaljerede instruktioner til betjening af KAIWEETS ST120 Smart Pen-type multimeteret, herunder sikkerhedsforanstaltninger, produktoversigtview, målefunktioner, tekniske specifikationer og vedligeholdelsesprocedurer.