1. Produktet er slutview
The ZFX W1209A is a high-precision digital temperature controller designed for a wide range of applications requiring accurate temperature management. It features a clear 3-digit LED display, an NTC waterproof probe for fluid temperature control, and a robust 30A relay output. This manual provides essential information for the proper setup, operation, and maintenance of your W1209A temperature controller.

Figur 1: Hoved view of the ZFX W1209A Digital Temperature Controller, showing the green PCB, LED display, control buttons, and terminal blocks.
2. Nøglefunktioner
- High Precision and Wide Measurement Range: Capable of measuring and controlling temperatures from -50°C to 110°C with 0.1°C accuracy.
- Waterproof NTC Probe: Includes a durable NTC 10K waterproof sensor, suitable for controlling fluid temperatures.
- Easy Installation and Operation: Designed for straightforward setup and user-friendly control.
- Klar LED-skærm: Features a bright 0.7-inch 3-digit LED display for easy temperature monitoring.
- Stabil ydeevne: Engineered for reliable and long-term operation.
- Høj strømudgang: Equipped with a 30A relay for controlling high-power loads.

Figure 2: The W1209A controller highlighting its digital display and control range of -50°C to 110°C.
3. Opsætning og ledningsføring
Before connecting, ensure all power sources are disconnected. Refer to the wiring diagram below for correct connections. Incorrect wiring can damage the device or connected equipment.
- Power Supply (12V DC): Connect a 12V DC power source to the two terminals labeled "12V Power Supply". Ensure correct polarity (positive to '+' and negative to '-').
- NTC sensor: Plug the NTC waterproof temperature probe into the "Sensor Socket" connector.
- Relæudgang: Connect the device you wish to control (e.g., heater, cooler) to the "Relay Output" terminals. This is a dry contact relay, meaning it acts as a switch. You will need to provide power to your controlled device separately, routed through these relay contacts. The relay can handle up to 30A.

Figure 3: Detailed wiring diagram of the W1209A controller, showing connections for the sensor, 12V DC power supply, and relay output.
After all connections are made, you can apply 12V DC power to the controller. The LED display will show the current temperature measured by the NTC probe.
4. Betjeningsvejledning
The W1209A controller has three buttons: SET, UP, and DOWN.
4.1. Setting the Target Temperature
- Tryk på SÆT button once. The display will flash, indicating the current target temperature.
- Brug UP og NED buttons to adjust the target temperature to your desired value.
- Trykke SÆT again to confirm and save the setting, or wait a few seconds for it to save automatically.
4.2. Accessing Parameter Settings (P0-P6)
To access advanced settings, press and hold the SÆT button for approximately 5 seconds. The display will show "P0". Use the UP og NED buttons to navigate through the parameters (P0 to P6).
Once you select a parameter (e.g., P0), press SÆT igen til view its current value. Use UP og NED for at ændre værdien. Trykke SÆT to confirm the new value and return to the parameter list, or hold SÆT to exit all settings.
Parameterbeskrivelser:
- P0: Cooling/Heating Mode (C/H)
- H (Heating Mode): The relay closes when the current temperature is below the set temperature minus the hysteresis. It opens when the current temperature reaches the set temperature.
- C (Cooling Mode): The relay closes when the current temperature is above the set temperature plus the hysteresis. It opens when the current temperature reaches the set temperature.
- P1: Hysteresis Setting (0.1-30°C)
Sets the difference between the turn-on and turn-off temperatures to prevent rapid cycling of the relay. - P2: Upper Limit of Temperature Setting (110°C)
Defines the maximum adjustable target temperature. - P3: Lower Limit of Temperature Setting (-50°C)
Defines the minimum adjustable target temperature. - P4: Temperature Correction (-7.0 to 7.0°C)
Allows for calibration of the temperature reading if there is a discrepancy with a known accurate thermometer. - P5: Delay Start Time (0-10 minutes)
Sets a delay before the relay activates after the temperature condition is met. Useful for compressors or other equipment that requires a delay. - P6: High Temperature Alarm (0-110°C)
If the current temperature exceeds this value, the display will show "HHH" and the relay will disconnect.
4.3. Gendannelse af fabriksindstillinger
To restore the controller to its factory default settings, power off the device. Then, press and hold both the UP og NED buttons simultaneously while powering on the device. The display will show "888" to confirm the reset.
5. Specifikationer

Figure 4: Dimensions of the ZFX W1209A controller, measuring approximately 75.5mm x 45mm.
| Parameter | Værdi |
|---|---|
| Model | ZFX-W1209A |
| Input bindtage | DC 12V |
| Produktion | 30A relæ |
| Temperaturkontrolområde | -50°C ~ 110°C |
| Temperaturmålingsnøjagtighed | 0.1°C |
| Kontrolnøjagtighed | 0.1°C |
| Opdateringshastighed | 0.5 sekunder |
| Temperatursensor | NTC 10K (300mm length) |
| Beskyttelse mod høj temperatur | 0°C ~ 110°C (P6 setting) |
| Driftsmiljø Temperatur | -10°C ~ 60°C |
| Driftsmiljø Fugtighed | 20 % ~ 85 % |
| Dimensioner | 75.5 mm x 45 mm |
| Pakkens indhold | 1 Temperature Controller with Probe |
6. Fejlfinding
- Display shows "LLL": Indicates the sensor is disconnected or damaged. Check the sensor connection or replace the sensor.
- Display shows "HHH": Indicates the measured temperature exceeds the upper limit (P6 setting) or the sensor is short-circuited. Check the sensor and the P6 setting.
- Display shows "---": Indicates the controller is in high-temperature protection mode (P6 activated) or the temperature is below the lower limit.
- Controlleren tænder ikke: Verify the 12V DC power supply connection and ensure correct polarity. Check the power source itself.
- Relæet aktiveres ikke:
- Check if the target temperature and current temperature conditions are met for the selected heating/cooling mode (P0).
- Verify the hysteresis setting (P1).
- Check if a delay start time (P5) is active.
- Ensure the controlled device is properly wired to the relay output and has its own power supply.
- Unøjagtig temperaturaflæsning: Use the temperature correction parameter (P4) to calibrate the sensor against a known accurate thermometer.
7. Vedligeholdelse
The ZFX W1209A temperature controller requires minimal maintenance. Keep the device clean and free from dust and moisture. Ensure all connections are secure. Avoid exposing the controller to extreme temperatures or corrosive environments beyond its specified operating range.
8. Garanti og support
Specific warranty information for this product is not provided in the available documentation. For support or warranty inquiries, please contact your retailer or the manufacturer directly with your purchase details.