This instruction manual provides essential information for the safe and efficient operation, installation, and maintenance of your FOTING 1.5HP Shallow Well Pump with Pressure Tank, Model JGP110037C. Please read this manual thoroughly before using the pump to ensure proper function and to prevent injury or damage. Keep this manual for future reference.

FOTING 1.5HP Shallow Well Pump with Pressure Tank

Figure 1: FOTING 1.5HP Shallow Well Pump with Pressure Tank

2. Sikkerhedsoplysninger

Overhold altid grundlæggende sikkerhedsforanstaltninger for at reducere risikoen for brand, elektrisk stød og personskade.

  • Elektrisk sikkerhed: Ensure the pump is connected to a properly grounded 115V, 60Hz power supply. Do not operate with damaged cords or plugs. Avoid using extension cords if possible; if necessary, use a heavy-duty outdoor-rated cord.
  • Vandsikkerhed: Do not pump flammable or corrosive liquids. Ensure the pump is not operated dry (without water), as this can cause severe damage.
  • Personlig sikkerhed: Wear appropriate personal protective equipment (PPE) such as safety glasses and gloves during installation and maintenance. Keep children and unauthorized persons away from the operating pump.
  • Installation: Install the pump in a well-ventilated area, protected from direct sunlight and freezing temperatures. Ensure all connections are secure and leak-free.
  • Opretholdelse: Afbryd strømmen, før du udfører vedligeholdelse eller service.

3. Produktet er slutview

The FOTING 1.5HP Shallow Well Pump with Pressure Tank is designed for efficient water boosting and irrigation applications. It features a powerful motor, a durable pressure tank, and automatic operation capabilities.

Nøglefunktioner:

  • Kraftig motor: 1.5HP motor with a maximum flow rate of 1340 GPH and a maximum lift of 164 feet.
  • High Suction Capability: Capable of suctioning water from depths up to 23 feet.
  • Integrated Pressure Tank: 5-gallon pressure tank with a pre-set pressure range for automatic operation.
  • Automatisk drift: Features a mechanical pressure switch that automatically starts the pump at 1.5 bar and shuts it off at 3 bar.
  • Holdbar konstruktion: Reinforced thermoplastic structure and a finely finished iron tank for corrosion and wear resistance.
  • Sikkerhedsfunktioner: Equipped with overheat protection to prevent motor burnout and a durable carbon ceramic mechanical seal to prevent water leakage.
  • Alsidige forbindelser: 1" NPT outlet and inlet, includes 2 adapters for NPT 1" to GHT 3/4" connections.
Product details diagram showing NPT outlet/intake, pressure tank, pressure gauge, switch, stable base.

Figur 2: Detaljeret view of pump components including 1" NPT Outlet, 1" NPT Intake, Start Waterproof Cover, 5-Gal Pressure Tank, High Pressure Soft Tube, Pressure Gauge, Mechanical Pressure Switch, and Stable Base.

Shallow well pump with pressure tank features: Max Suction Lift 23FT, Max Height 164FT, Protection Type IPX4, Overheat Protection.

Figure 3: Key performance specifications and protection features.

Close-up of pressure gauge, mechanical pressure switch (Auto On <1.5bar, Auto Off >3.0bar), and thermal overload protection.

Figure 4: Details of the pressure gauge, mechanical pressure switch, and thermal overload protection.

4. Opsætning og installation

4.1 Udpakning

Fjern forsigtigt alle komponenter fra emballagen. Undersøg for eventuelle skader, der kan være opstået under forsendelsen. Sørg for, at alle dele, der er anført på pakkelisten, er til stede.

4.2 Placering

Place the pump on a stable, level surface. The location should be protected from moisture, direct sunlight, and freezing temperatures. Ensure adequate ventilation around the motor.

4.3 VVS-tilslutninger

  1. Connect the suction line to the 1" NPT intake port of the pump. Ensure a tight, leak-free connection.
  2. Connect the discharge line to the 1" NPT outlet port. Use the provided NPT 1" to GHT 3/4" adapters if connecting to a standard garden hose.
  3. It is recommended to install a check valve on the suction line to prevent water from flowing back into the well or source, especially for self-priming applications.
  4. Ensure all pipes and fittings are compatible with the intended water pressure and temperature.
Water methods: water taps and self-priming, showing NPT 1 inch to GHT 3/4 inch connector and IP54 protection.

Figure 5: Connection options for water taps and self-priming setups.

4.4 Spædning af pumpen

Before first use, the pump must be primed.

  1. Locate the priming plug on the top of the pump housing.
  2. Remove the priming plug and slowly fill the pump casing with water until it overflows.
  3. Sæt spædeproppen sikkert på igen.
  4. Ensure the suction line is fully submerged in the water source.

4.5 Elektrisk tilslutning

Connect the pump to a standard 115V, 60Hz grounded electrical outlet. Ensure the power switch on the pump is in the "OFF" position before plugging it in.

5. Betjeningsvejledning

5.1 Start af pumpen

  1. Ensure the pump has been properly primed (see Section 4.4).
  2. Turn the power switch to the "ON" position. The pump will start to draw water.
  3. Observe the pressure gauge. The pump's mechanical pressure switch is set to automatically start when pressure drops below 1.5 bar and shut off when it reaches 3 bar. The maximum pressure the tank can hold is 4.5 bar.
  4. Allow the pump to run until a steady flow of water is achieved and the pressure stabilizes.

5.2 Ansøgninger

Denne pumpe er egnet til forskellige anvendelser, herunder:

  • Garden and lawn irrigation.
  • Agricultural structures and small farms.
  • Domestic water supply for homes and cabins.
  • Pipe pressurization and water transfer.
A person irrigating a garden with the FOTING pump, highlighting its use for garden irrigation with max height 164ft, max suction 23ft, and max 1340 GPH.

Figure 6: Pump in use for garden irrigation.

Three images showing various applications: a child watering a garden, farm irrigation, and water transfer with a pressure washer.

Figure 7: Versatile applications of the FOTING pump.

6. Vedligeholdelse

Regular maintenance ensures the longevity and optimal performance of your FOTING pump. Always disconnect power before performing any maintenance.

6.1 Generel rengøring

  • Keep the pump exterior clean and free from debris.
  • Sørg for, at ventilationsåbningerne ikke er blokeret for at forhindre overophedning.

6.2 Vinterklargøring (til kolde klimaer)

If the pump is exposed to freezing temperatures, it must be drained to prevent damage.

  1. Afbryd pumpen fra strømforsyningen.
  2. Tøm alt vand ud af pumpen casing and pressure tank by opening drain plugs and disconnecting pipes.
  3. Store the pump in a warm, dry place during winter months.

6.3 Mekanisk tætning

The pump is equipped with a durable carbon ceramic mechanical seal designed to prevent water leakage and extend service life. If leakage occurs around the shaft, inspect the seal for wear or damage and replace if necessary.

7. Fejlfinding

Refer to the table below for common issues and their solutions. If the problem persists, contact FOTING customer service.

ProblemMulig årsagLøsning
Pumpen starter ikke.No power; tripped circuit breaker; faulty switch; motor overload.Check power connection; reset breaker; inspect switch; allow motor to cool if overheat protection activated.
Pumpen kører, men intet vand eller lavt flow.Pump not primed; air leak in suction line; clogged intake; low water source.Re-prime the pump; check suction line for leaks; clear intake; ensure adequate water source.
Pumpen tænder og slukker ofte.Air in pressure tank; pressure switch malfunction; small leak in system; no check valve on suction line.Check air charge in tank; inspect pressure switch; check for leaks in plumbing; install a check valve on the suction line if not present.
Pumpen er støjende.Cavitation (air in water); worn bearings; foreign object in impeller.Ensure pump is fully primed and suction line is sealed; inspect impeller for obstructions; contact service if bearings are suspected.
Vandlækage.Loose connections; damaged mechanical seal; cracked housing.Tighten all connections; inspect and replace mechanical seal if damaged; contact service for housing damage.

8. Specifikationer

AttributVærdi
MærkeFOTING
ModelnummerJGP110037C
Magt1.5 HK
Voltage115 volt
Frekvens60 Hz
Max flowhastighed1340 GPH
Max Lift (Head)164 fod
Maks. sugeløft23 fod
Trykbeholderkapacitet5 gallons
Automatic Pressure Switch On< 1.5 bar
Automatic Pressure Switch Off> 3.0 bar
Max Pressure (Tank)4.5 bar
Indgang / udgangsstørrelse1" NPT
MaterialePlast, Metal
Produktmål (L x B x H)17 cm x 10.5 cm x 20 cm
Varens vægt33.7 pund
BeskyttelsestypeIPX4
Max væsketemperatur95°F
Working performance diagram showing max height-lift 164FT, 23FT max suction, and flow rates at different heights.

Figure 8: Pump working performance chart.

9. Garanti og kundesupport

FOTING er forpligtet til at levere produkter af høj kvalitet og fremragende kundeservice.

9.1 Garantioplysninger

Specific warranty details may vary. Please refer to the product packaging or contact FOTING customer service for comprehensive warranty information regarding your 1.5HP Shallow Well Pump with Pressure Tank.

9.2 Kundesupport

For technical support, troubleshooting assistance, or any inquiries regarding your FOTING product, please contact our customer service team. Our professionals are available to provide support and ensure your water system remains stable.

You can find contact information on the official FOTING webwebsted eller via din købsplatform.

Documents - FOTING – JGP110037C