Indledning
This manual provides comprehensive instructions for the TOOLTOP TT-BSIDE-O2, a versatile 3-in-1 device integrating a digital oscilloscope, digital multimeter, and signal generator. Designed for professionals and enthusiasts, this instrument features a touch screen interface, dual-channel capabilities, and a robust design for various electrical testing and measurement applications.
Hvad er der i æsken

Image: The TOOLTOP TT-BSIDE-O2 device displayed alongside its standard accessories, including test leads, a USB charging cable, and a protective carrying case, illustrating the complete package contents.
Upon unboxing your TOOLTOP TT-BSIDE-O2, please verify that all the following items are present:
- TOOLTOP TT-BSIDE-O2 Main Unit
- Oscilloscope Probes (Quantity: 2)
- Multimeter testledninger
- USB opladningskabel
- Beskyttende bæretaske
- Brugervejledning (dette dokument)
Nøglefunktioner

Billede: En detaljeret view of the device emphasizing its high-quality display, protective silicone casing, intuitive function wheel for navigation, and the versatile Type-C port for both data transfer and charging.
- 2-IN-1 Professional Digital Oscilloscope + DDS Function Signal Generator: Combines two essential tools into one compact device.
- High-Definition TFT Display: Features a 3.98-inch 480*320px resolution screen for clear waveform visualization.
- Indbygget genopladeligt batteri: Equipped with a 3000mAh lithium battery (18650 battery*2) for extended portable use.
- Dual-Channel Oscilloscope: Offers 2X50MHz bandwidth and a 50MS/s real-time sampling rate for precise measurements.
- Signal Generator Capabilities: Generates signals from 0Hz to 2MHz with an output amplitude of 0.1V to 3.0V and a minimum resolution of 1Hz.
- Full Touchscreen Operation: Intuitive touch interface for easy navigation and parameter adjustment.
- Bølgeformbesparelse: Ability to save waveform data for later analysis.
- Firmwareopgraderinger: Supports firmware updates for enhanced functionality.
- Intelligent Anti-Burning Protection: Designed with safety features to prevent damage.
- Computer Mapping: Connects to a PC via USB for secondary analysis and data management.
Opsætningsvejledning
1. Første opladning
Before first use, fully charge the device. Connect the provided USB cable to the Type-C port on the device and the other end to a standard USB power adapter (not included) or a computer USB port. The charging indicator will illuminate during charging and turn off when fully charged. A full charge typically takes approximately 3-4 hours.
2. Tænd/sluk
To power on the device, press and hold the power button located on the side until the screen illuminates. To power off, press and hold the power button again until the device shuts down.
3. Grundlæggende navigation
The device features a full touchscreen for most operations. Additionally, a function wheel is provided for precise adjustments and menu navigation. Rotate the wheel to scroll through options and press it to confirm selections.
Betjeningsvejledning
1. Oscilloskoptilstand
Oscilloskopfunktionen muliggør visualisering og analyse af elektriske signaler over tid.
- Tilslutning af sonder: Connect the oscilloscope probes to the BNC connectors labeled "OSC 1" and "OSC 2" on the top of the device. Ensure a secure connection.
- Sondekalibrering: For accurate measurements, it is recommended to calibrate the probes before use. Refer to the on-screen menu for probe calibration options.
- Valg af kanaler: Use the touchscreen to select the desired input channel (CH1 or CH2).
- Justering af parametre:
- Vertikal skala (volt/divider): Juster voltage per division to fit the waveform vertically on the screen.
- Horisontal skala (tid/division): Adjust the time per division to view the waveform's period or frequency.
- Triggerindstillinger: Set the trigger level, slope, and mode (Auto, Normal, Single) to stabilize the waveform display.
- Målefunktioner: The device can automatically measure various waveform parameters such as Vpp (peak-to-peak voltage), Vmax, Vmin, Vavg, RMS, Frequency, and Duty Cycle. Access these measurements via the on-screen menu.
- Bølgeformbesparelse: Use the save function to store waveform data for later review or transfer to a computer.
2. Signalgeneratortilstand
The built-in signal generator can produce various waveforms for testing circuits.

Image: The device screen showing the signal generator menu, allowing users to select from various waveform types and precisely adjust frequency and amplitude settings for output.
- Accessing Signal Generator: Navigate to the signal generator mode from the main menu.
- Tilslutningsudgang: Connect the signal generator output lead to the designated port on the device.
- Valg af bølgeformtype: Choose from available waveform types (e.g., Sine, Square, Triangle, Sawtooth).
- Indstillingsfrekvens: Adjust the output frequency from 0Hz to 2MHz using the touchscreen or function wheel.
- Indstilling Amplitude: Juster outputtet amplitude from 0.1V to 3.0V.
- Udsender signal: Activate the signal output to generate the configured waveform.
3. Multimetertilstand
The multimeter function provides standard electrical measurements.
- Tilslutning af testledninger: Connect the red and black multimeter test leads to the appropriate input jacks on the device.
- Valg af målefunktion: Use the touchscreen to select the desired measurement function (e.g., DC Voltage, AC Voltage, Resistance, Continuity, Diode Test).
- Udførelse af måling: Apply the test leads to the circuit or component under test according to standard multimeter practices. The measurement will be displayed on the screen.
4. Data Management and PC Connection

Image: The device connected to a laptop, illustrating its capability to transfer saved waveform data and other measurement results to a computer for further analysis and storage.
The device supports connection to a PC via its Type-C USB port for data transfer and secondary analysis of waveform data. When connected, the device may appear as a mass storage device, allowing you to access saved files. Specific software or drivers may be required for advanced analysis; refer to the manufacturer's webwebsted for detaljer.
Opretholdelse
- Rensning: Brug en blød, tør klud til at rengøre enheden. Ved genstridigt snavs, rens letamp cloth with mild detergent can be used, ensuring no liquid enters the ports or openings. Do not use abrasive cleaners or solvents.
- Batteripleje: To prolong battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge it to approximately 50% and recharge every few months.
- Opbevaring: Store the device in a cool, dry place, away from direct sunlight, extreme temperatures, and high humidity. Use the provided protective carrying case for transport and storage to prevent physical damage.
- Firmwareopdateringer: Periodically check the TOOLTOP official website for available firmware updates. Keeping the firmware updated ensures optimal performance and access to new features.
Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | Lavt batteri eller helt afladet. | Connect the device to a power source using the USB cable and allow it to charge for at least 30 minutes before attempting to power on again. |
| No waveform displayed in Oscilloscope mode. | Probe not connected correctly; incorrect trigger settings; signal too small or too large. | Ensure probes are securely connected. Adjust trigger level and mode. Adjust vertical (Volts/Div) and horizontal (Time/Div) scales to match the input signal. |
| Signal generator output is incorrect or absent. | Forkert frekvens/amplitude settings; output lead not connected. | Bekræft hyppighed og amplitude settings. Ensure the signal generator output lead is properly connected to the device and the circuit under test. |
| Touchscreen reagerer ikke. | Midlertidig softwarefejl; skærm snavset. | Restart the device. Clean the screen with a soft, dry cloth. If the issue persists, contact customer support. |
| Kan ikke oprette forbindelse til pc'en. | Faulty USB cable; incorrect PC settings; missing drivers. | Try a different USB cable. Ensure the device is in PC connection mode (if applicable). Check PC device manager for driver issues and install necessary drivers from the manufacturer's webwebsted. |
Tekniske specifikationer
| Feature | Specifikation |
|---|---|
| Mærke | VÆRKTØJ TOP |
| Modelnummer | TT-BSIDE-O2 |
| Vise | 3.98 inch 480*320px TFT Touch Screen |
| Oscilloskop båndbredde | Dual-channel 2X50MHz |
| Realtids Sampling Rate | 50 MS/s |
| Signal Generator Frequency Range | 0Hz ~ 2MHz |
| Signalgenerator output Amplitude | 0.1V~3.0V |
| Batteri | Built-in 3000mAh rechargeable lithium battery (18650 battery*2) |
| Forbindelse | Type-C USB for data transfer and charging |
| Varens vægt | 1 kilogram (2.2 pund) |
| Pakkedimensioner | 7.87 x 5.91 x 3.94 tommer |
| Certificeringer | CE, RoHS |
| Første ledige dato | 21. april 2025 |
Garanti og support
The TOOLTOP TT-BSIDE-O2 comes with a manufacturer's warranty. For specific warranty terms and conditions, including duration and coverage, please refer to the warranty card included with your product or visit the official TOOLTOP website. Spare part availability is indicated for 1 year from the date of purchase.
For technical support, troubleshooting assistance beyond what is provided in this manual, or warranty claims, please contact TOOLTOP customer service directly. Contact information can typically be found on the manufacturer's webwebstedet eller på produktemballagen.
Fabrikant: VÆRKTØJ TOP