SUNGOLDPOWER SPH10K48SP-P

SUNGOLDPOWER SPH10K48SP-P 10000W 48V solcelle-inverter brugsanvisning

1. Introduktion

This manual provides essential information for the safe and efficient operation of your SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter. Please read all instructions and warnings carefully before installation and use. Retain this manual for future reference.

Sikkerhedsforanstaltninger:

  • Ensure all electrical connections are made by qualified personnel.
  • Afbryd altid strømmen, før du udfører vedligeholdelse eller service.
  • The inverter is heavy; use proper lifting techniques or assistance during installation.
  • Install in a well-ventilated area to prevent overheating.

2. Pakkens indhold

Bekræft, at alle nedenstående varer er inkluderet i din pakke:

  • SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter
  • WiFi-modul
  • WiFi monitoring components
  • Brugermanual
  • Garantikort
  • Parallel COM cable
  • Kommunikationskabel
  • Cable lugs & Screws
SUNGOLDPOWER SPH10K48SP-P Inverter and Accessories
Figure 2.1: SUNGOLDPOWER SPH10K48SP-P Inverter and included accessories, including the WiFi module, cables, and mounting hardware.

3. Produktet er slutview

The SUNGOLDPOWER SPH10K48SP-P is an all-in-one solar charge inverter designed for robust off-grid and hybrid solar systems. It integrates a 10000W pure sine wave inverter, two MPPT solar controllers, and a 200A battery charger, offering flexible AC input/output options (120V/240V settable).

Front view of the SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter
Figur 3.1: Forside view of the SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter, showcasing det er blå casing and integrated LCD display.

Nøglefunktioner:

  • Alt-i-en Design: Combines inverter, MPPT solar controllers, and battery charger.
  • Høj effekt: 10000W rated power, 20000W peak power.
  • Dual MPPT Solar Controllers: Max 200A battery charging, 500VDC open circuit voltage.
  • Flexible AC Output: Settable 120V/240V split phase or 120V single phase.
  • Pure Sine Wave Output: Sikrer kompatibilitet med følsom elektronik.
  • WiFi modul: Allows remote monitoring and parameter adjustment via mobile app.
  • BMS kommunikation: Supports various battery types including Lithium with CAN, USB, and RS485.
  • Flere driftstilstande: Four charging and four output modes for diverse energy management.
  • Time-Slot Function: Optimizes charging/discharging based on tariff rates.
  • UL1741-certificeret: Sikrer sikkerhed og pålidelighed.
Key features of the SUNGOLDPOWER 10KW Pure Sine Wave Inverter
Figure 3.2: Visual representation of the inverter's key specifications, including 11000W Max PV Array Power, 500V Max Open Circuit Voltage, and 200A Max Charge Current.
LCD HD Display of the SUNGOLDPOWER Inverter
Figure 3.3: The inverter's LCD HD display, showing real-time data and options for setting various parameters.

4. Opsætning

4.1 Fysisk installation

The inverter should be mounted securely in a location that is dry, well-ventilated, and protected from direct sunlight and extreme temperatures. Due to its weight (54 lbs), ensure the mounting surface can support the load. Consider accessibility for future adjustments and maintenance.

4.2 Elektriske forbindelser

All electrical wiring must comply with local and national electrical codes. Use appropriate wire gauges for all connections to ensure safety and optimal performance.

4.2.1 Battery Connections

Connect the battery cables to the inverter's battery terminals. Ensure correct polarity: positive (+) to positive and negative (-) to negative. Tighten all connections securely to prevent loose contacts and potential hazards.

System Connection Diagram for SUNGOLDPOWER Inverter
Figure 4.1: A comprehensive system connection diagram illustrating how PV panels, generator, mains, external battery packs, and home appliances connect to the SUNGOLDPOWER inverter in both split-phase and single-phase modes.

4.2.2 PV Input Connections

Connect your solar PV array to the designated PV input terminals on the inverter. Observe correct polarity and ensure the open circuit voltage of the PV array does not exceed 500VDC.

4.2.3 AC Input/Output Connections

Connect the AC input from your utility grid or generator, and the AC output to your loads. The inverter supports both 120V/240V split-phase and 120V single-phase configurations. Refer to the wiring diagram for specific connections.

4.3 Første opstart og konfiguration

After all physical and electrical connections are made, proceed with the initial power-up. The inverter's LCD display allows for configuration of various settings, including battery type, charging modes, and output priorities.

Installation and Wiring Overview

Video 4.1: This video demonstrates the unboxing and initial wiring process for the SUNGOLDPOWER inverter, including connecting battery wires and grounding. It highlights the importance of secure connections and proper placement.

Battery and Inverter Communication Setup

Video 4.2: This video provides a detailed guide on connecting the battery pack to the inverter and configuring communication settings. It covers positive and negative terminal connections, RS485/CAN communication, and initial startup procedures, including setting DIP switches and verifying voltage.

5. Driftstilstande

The SPH10K48SP-P inverter offers versatile operating modes to optimize energy usage based on your specific needs:

5.1 opladningstilstande:

  • Hybridopladning: Utilizes both solar and utility power for battery charging.
  • Utility Priority Charging: Prioritizes utility power for charging, with solar as a supplement.
  • Solar Priority Charging: Prioriterer solenergi til opladning med elforsyning som backup.
  • Only Solar Charging: Charges batteries exclusively from solar power.

5.2 Output Modes:

  • Prioritet af forsyningsvirksomheder: Belastninger forsynes primært af forsyningsnettet.
  • Solar and Utility Hybrid: Dynamically uses solar and utility to power loads.
  • Solprioritet: Loads are primarily powered by solar, then batteries, then utility.
  • Inverterprioritet: Loads are primarily powered by the inverter (from batteries/solar), then utility.
Diagram illustrating the four AC output modes and four battery charging modes of the SUNGOLDPOWER inverter
Figure 5.1: Visual guide to the various working modes, detailing how power flows from utility, solar, and battery to loads under different priority settings.

6. Time-Slot Charging/Discharging Function

The inverter features a time-slot function, allowing users to configure specific charging and discharging periods. This is particularly useful for optimizing energy usage based on local peak and off-peak electricity tariffs, maximizing savings and efficient use of PV energy.

  • Time-slot Utility Charging/Carrying: Set up to three definable periods for utility charging. If PV energy is unavailable or insufficient, utility energy will be used as a supplement.
  • Time-slot Battery Discharging: Set up to three definable periods for battery discharging. During these periods, the inverter prioritizes battery power for loads, switching to mains power if battery power is insufficient.
Diagram explaining the time-slot charging and discharging functions of the SUNGOLDPOWER inverter
Figure 6.1: Illustration of the time-slot charging and discharging feature, showing how users can set periods to utilize mains and battery power according to peak and valley tariffs.

7. Batterikompatibilitet

The SPH10K48SP-P inverter is compatible with a wide range of 48V battery types, including:

  • AGM/Sealed
  • Gel
  • Oversvømmet
  • Litium (LiFePO4)
  • User-defined (for custom battery parameters)

It also supports battery-free operation. For lithium batteries, the mains power and photovoltaics can activate a dormant battery. The inverter supports CAN, USB, and RS485 communication with SUNGOLDPOWER batteries for enhanced management.

SUNGOLDPOWER Inverter compatibility with various battery types
Figure 7.1: Diagram showing the inverter's compatibility with different battery chemistries, including Flooded, AGM, GEL, Sealed Lead Acid, LiFePO4, and user-defined settings.

8. Parallel Function

For increased power output or to create a three-phase system, the SPH10K48SP-P inverter supports parallel connection of up to 6 units. This allows for scalable power solutions to meet diverse energy demands.

Wiring diagrams for split-phase and three-phase parallel connections of SUNGOLDPOWER inverters
Figure 8.1: Detailed wiring diagrams for connecting multiple inverters in parallel for both split-phase (two units) and three-phase (three or more units) configurations.

9. Communication & Monitoring

The integrated WiFi module allows users to monitor the inverter's operating status and parameters remotely via a mobile application. BMS communication (CAN, USB, RS485) ensures seamless integration and optimized performance with compatible battery systems.

SUNGOLDPOWER Inverter with WiFi monitoring capabilities
Figure 9.1: The inverter connected to a WiFi module, illustrating remote monitoring of solar, battery, and home energy usage via a smartphone application.

10. Vedligeholdelse

Regular maintenance ensures the longevity and optimal performance of your inverter. Perform the following checks periodically:

  • Visuel inspektion: Check for any visible damage, loose connections, or signs of overheating.
  • Rensning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow. Use a dry cloth for cleaning.
  • Tilslutningstjek: Periodically verify that all electrical connections (battery, PV, AC) are tight and secure.
  • Miljø: Sørg for, at installationsmiljøet forbliver inden for de angivne temperatur- og luftfugtighedsintervaller.

11. Fejlfinding

If the inverter displays an error code or exhibits unusual behavior, consult the user manual for specific troubleshooting steps. Common issues and general solutions include:

  • Ingen strøm: Check all circuit breakers, battery connections, and input power sources.
  • Lav udgangseffekt: Verify PV array performance, battery state of charge, and load requirements.
  • Advarsel om overbelastning: Reduce connected loads. Ensure total load does not exceed the inverter's rated capacity.
  • Kommunikationsfejl: Check communication cables and settings for BMS or WiFi modules.

For persistent issues, contact SUNGOLDPOWER customer support.

12. Specifikationer

Detailed technical specifications for the SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter:

FeatureSpecifikation
Modelnavn10KW 48V Split Phase Solar Inverter
Nominel udgangseffekt10,000W
Maks. Peak Power20,000W
Nominel output Voltage120/240Vac (split phase/single phase)
Motorernes belastningskapacitet6 HK
Nominel AC -frekvens50/60Hz
Parallel kapacitet6 enheder
BatteritypeLi-ion / bly-syre / brugerdefineret
Nominel batteri voltage48V jævnstrøm
VoltagRækkevidde40-60VDC
Maks. MPPT Ladestrøm200A
Max. Mains/Generator Charging Current120A
Max. Hybrid Charging Current200A
Num. of MPPT Trackers2
Maks. PV Array Power11,000W
Maks. Indgangsstrøm22/22A
Maks. Voltage af åbent kredsløb500V jævnstrøm
MPPT bindtagRækkevidde125-425VDC
Bypass overbelastningsstrøm63A
MPPT-sporingseffektivitet99.9 %
Support CommunicationWiFi Modules/RS485 /CAN/USB/Dry contact
Produktdimensioner26 x 17.9 x 4.9 tommer
Varens vægt54 pund
Table of specifications for SUNGOLDPOWER SPH8048P and SPH10048P inverters
Figure 12.1: A comparative table of specifications for the SPH8048P and SPH10048P models, detailing power, voltage, current, and communication features.

13. Garanti og support

SUNGOLDPOWER products are backed by a manufacturer's warranty. Please refer to the included Warranty Card for detailed terms and conditions. For technical assistance, troubleshooting, or warranty claims, please contact SUNGOLDPOWER customer support through their official channels.

Relaterede dokumenter - SPH10K48SP-P

Preview Brugermanual til SunGoldPower SPH-seriens alt-i-en solcelleladningsinverter
Omfattende brugermanual til SunGoldPower SPH-seriens alt-i-en solcelle-ladeinvertere, der dækker installation, drift, vedligeholdelse og tekniske specifikationer for modellerne SPH8K48SP og SPH10K48SP.
Preview Fejlfindingsvejledning til Sungoldpower Pure Sine Wave-inverteroplader
En omfattende fejlfindingsvejledning til Sungoldpower Pure Sine Wave-inverteropladere, der dækker almindelige problemer såsom unormale AC-aflæsninger, problemer med batteriopladning, udgangsfejl og ventilatordrift.
Preview Brugermanual til LFP-serien af ​​ren sinusbølge-inverter/oplader
Brugermanual til LFP-serien af ​​ren sinusbølgeinverter/oplader, med detaljerede sikkerhedsoplysninger, introduktion, installation, elektrisk ydeevne, fejlfinding og specifikationer.
Preview Sungoldpower SPH8K48SP / SPH10K48SP Alt-i-en solcelleladningsinverter brugermanual
Omfattende brugermanual til Sungoldpower SPH8K48SP og SPH10K48SP alt-i-en solcelle-ladeinverterne, der dækker sikkerhed, installation, drift, kommunikation, fejlfinding og tekniske specifikationer.
Preview SunGoldPower SPH302480A Alt-i-en solcelleladningsinverter brugermanual
Denne brugermanual indeholder omfattende instruktioner til SunGoldPower SPH302480A alt-i-en hybrid solcelle-opladningsinverteren, der dækker sikkerhed, installation, driftstilstande, LCD-skærmfunktioner, andre funktioner, beskyttelsesmekanismer, systemvedligeholdelse og detaljerede tekniske parametre.
Preview Brugermanual til SunGoldPower energilagringssystem
Brugermanual til SunGoldPower energilagringssystem (ESS), der dækker installation, tilslutning, drift, vedligeholdelse og tekniske specifikationer for modellerne SGN7.6K1HB-48 og SGN11.4KHB-48.