Banner Engineering M18TUP14

M18TUP14 Industrial Temperature Sensor User Manual

Model: M18TUP14 | Brand: Banner Engineering

1. Introduktion og overview

The Banner Engineering M18TUP14 is an industrial temperature sensor designed for precise temperature measurement in various industrial applications. This sensor features a 1 Germanium Lens, providing accurate readings within a temperature range of -20°C to +300°C. It offers an analog 0-10V output for continuous temperature monitoring and a PNP alarm output for threshold detection. The robust design, including an IP67 rating, ensures reliable performance in demanding environments. This manual provides essential information for the safe and effective installation, operation, and maintenance of your M18TUP14 sensor.

2. Sikkerhedsoplysninger

Read all instructions carefully before installing or operating the M18TUP14 sensor. Failure to follow these instructions may result in product damage, property damage, or serious injury.

3. Pakkens indhold

Kontroller, at alle genstande er til stede og ubeskadigede ved udpakning:

Hvis der mangler eller er beskadigede komponenter, skal du straks kontakte din leverandør.

4. Specifikationer

ModelM18TUP14
FabrikantBanner Engineering
Temperaturområde-20°C til +300°C (-4°F til +572°F)
Driftsforsyning Voltage12V til 30V DC
UdgangstypeAnalog 0-10V, PNP Alarm
Linsetype1 Germanium Lens
Kabellængde2 m (6.5 fod)
IP-vurderingIP67
Varens vægt6.99 pund (ca. 3.17 kg)

5. Opsætning og installation

Proper installation is crucial for the accurate and reliable operation of the M18TUP14 sensor.

5.1 Montering

The M18TUP14 sensor features an M18 threaded barrel for easy mounting. Use appropriate mounting hardware (not included) to secure the sensor in the desired location. Ensure the sensor's lens is unobstructed and has a clear line of sight to the target area for temperature measurement. The IP67 rating ensures protection against dust and temporary immersion in water, making it suitable for harsh industrial environments.

M18TUP14 Industrial Temperature Sensor showing its threaded body, power and output indicators, and TEACH button.

Figure 1: M18TUP14 Industrial Temperature Sensor. The image displays the cylindrical, threaded body of the sensor, with a black end housing the power (PWR) and output (OUT) indicator LEDs, and a 'TEACH' button. The sensor terminates in a threaded connector for wiring.

5.2 Ledningsføring

Connect the sensor to your control system according to the following general guidelines. Refer to the specific wiring diagram provided with your sensor for detailed connections. Ensure power is OFF before wiring.

6. Betjening

Once installed and wired, the M18TUP14 sensor is ready for operation.

6.1 Power-Up and Indicators

Upon applying power, the PWR (Power) indicator LED on the sensor will illuminate, typically green, indicating that the sensor is receiving power. The UD (Output) indicator LED will illuminate when the PNP alarm output is active (i.e., when the measured temperature exceeds the set alarm threshold).

6.2 Analog Output Reading

The 0-10V analog output provides a continuous representation of the measured temperature. You will need to scale this voltage reading in your control system (PLC, HMI, etc.) to convert it into a temperature value (e.g., degrees Celsius or Fahrenheit) based on the sensor's specified temperature range (-20°C to +300°C).

F.eksample, 0V might correspond to -20°C and 10V to +300°C. Consult the sensor's data sheet for the exact scaling factor if not provided here.

6.3 Setting Alarm Threshold (TEACH Function)

The 'TEACH' button on the sensor is used to set the PNP alarm threshold. The exact procedure may vary slightly, but typically involves:

  1. Place the sensor in the environment or at the temperature you wish to set as the alarm threshold.
  2. Press and hold the 'TEACH' button for a specified duration (e.g., 2-5 seconds) until the OUT indicator flashes, indicating it has learned the new threshold.
  3. Release the button. The sensor is now configured, and the PNP alarm will activate when the temperature exceeds this newly taught value.

Refer to the detailed programming instructions in the full Banner Engineering product manual for advanced teaching modes or specific timing requirements.

7. Vedligeholdelse

The M18TUP14 sensor is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

8. Fejlfinding

If you encounter issues with your M18TUP14 sensor, consider the following common troubleshooting steps:

ProblemMulig årsagLøsning
Ingen strøm (PWR-LED slukket)Ingen strømforsyning; Forkert ledningsføring; Defekt strømforsyning.Kontroller strømtilslutninger og volumentage (12-30V DC). Verify wiring polarity. Test power supply.
Incorrect Analog Output ReadingSensor lens obstructed/dirty; Incorrect scaling in controller; Sensor outside temperature range.Clean sensor lens. Verify scaling parameters in your control system. Ensure target temperature is within -20°C to +300°C.
PNP Alarm Not TriggeringIncorrect alarm threshold set; Wiring issue; Temperature not reaching threshold.Re-teach the alarm threshold using the 'TEACH' button. Check PNP output wiring. Verify actual temperature.
Intermitterende aflæsningerLoose wiring connections; Electrical interference; Unstable power supply.Secure all wiring connections. Ensure proper grounding. Use shielded cables if interference is suspected.

If the problem persists after attempting these steps, contact Banner Engineering technical support or your authorized distributor for further assistance.

9. Garanti og support

For information regarding the warranty of your M18TUP14 Industrial Temperature Sensor, please refer to the warranty statement provided by Banner Engineering or contact your point of purchase (e.g., Neutron USA). Technical support and additional resources can typically be found on the official Banner Engineering webhjemmeside eller ved at kontakte deres kundeserviceafdeling.

Fabrikant: Banner Engineering

ASIN: B0F4JSFBPY

Relaterede dokumenter - M18TUP14

Preview Banner M18T Series Infrared T-GAGE Temperature Sensor with Analog Output
Detailed information on the Banner M18T Series Infrared T-GAGE Temperature Sensor, including features, models, specifications, wiring, configuration, and maintenance.
Preview Banner T-GAGE M18T Series Infrared Temperature Sensors: Features, Specifications, and Applications
Comprehensive guide to Banner Engineering's T-GAGE M18T Series Infrared Temperature Sensors, detailing features, model specifications, sensing capabilities, programming methods, dimensions, and accessories for industrial temperature measurement.
Preview Banner M18T Series T-GAGE® Temperature Sensor with Discrete Outputs | Technical Specifications
Detailed technical specifications, features, applications, and configuration guide for the Banner M18T Series T-GAGE® temperature sensor with discrete outputs. Includes wiring diagrams, sensor configuration, and product support information.
Preview WLS70 Industrial LED Strip Light (AC) - Product Manual & Specifications
Comprehensive product manual and specifications for the Banner WLS70 Industrial LED Strip Light (AC), detailing features, installation, technical data, accessories, and warranty. This guide provides essential information for industrial and harsh environment applications.
Preview Q90R R-GAGE® Radar Sensor Instruction Manual | Banner Engineering
Comprehensive instruction manual for the Banner Q90R R-GAGE® Radar Sensor, covering product description, installation, configuration, specifications, and product support. Learn how to set up and use this industrial radar sensor.
Preview Banner R45C Analog Output to IO-Link Device Converter: Quick Start Guide
Quick start guide for the Banner R45C Analog Output to IO-Link Device Converter. Learn about setup, installation, specifications, and troubleshooting for this rugged, IP-rated industrial sensor converter.