1. Introduktion
The Vertiv Liebert IntelliSlot RDU120 Network Card is an advanced remote monitoring adapter designed to enhance the management capabilities of Vertiv products. This card facilitates secure and flexible communication, enabling real-time data access and system status monitoring for critical infrastructure.
1.1 Produkt overview
The RDU120 provides web access and data transmission via industry-standard protocols such as SNMP, Modbus, and BACNet. It supports environmental monitoring through compatible Geist Sensors for parameters like temperature, humidity, leak detection, and contact closures. Its UL2900-1 cybersecurity certification ensures secure online communication and data integrity.
1.2 Nøglefunktioner
- UL2900-1 Cybersecurity Certified: Ensures secure online communication.
- Secure Boot with Hardware Trust Anchor: Prevents unauthorized software tampering.
- Fleksibel kommunikation: Supports SNMP, Modbus, and BACnet protocols.
- Standard RESTful API Support: Facilitates easy configuration and updates.
- 1 Gb Ethernet: Compatible with modern network environments and web browsere.
- Miljøovervågning: Supports Geist Sensors for various environmental parameters.
2. Sikkerhedsoplysninger
Please read and understand all safety instructions before installing or operating the Vertiv Liebert IntelliSlot RDU120 Network Card. Failure to follow these instructions may result in injury, damage to the product, or voiding of the warranty.
- Ensure the host device is powered off and disconnected from the power source before installation.
- Handle the network card by its edges to avoid touching electronic components.
- Use appropriate electrostatic discharge (ESD) precautions when handling the card.
- Udsæt ikke kortet for fugt eller ekstreme temperaturer.
- Only use accessories and cables approved by Vertiv.
3. Pakkens indhold
Kontroller, at alle varer er til stede og ubeskadigede, når du åbner pakken:
- Vertiv Liebert IntelliSlot RDU120 Network Card
- Hurtigstartguide (hvis relevant)
- Monteringsskruer (hvis relevant)
Hvis der mangler eller er beskadigede dele, skal du straks kontakte din leverandør.
4. Produktet er slutview
Familiarize yourself with the physical components and ports of the RDU120 Network Card.

Figur 4.1: Samlet set view of the RDU120 Network Card, displaying the circuit board and connectors.

Figur 4.2: Vinklet view of the RDU120, showing the front panel and card profile.

Figur 4.3: Detaljeret view of the RDU120 front panel, indicating port labels.

Figur 4.4: Side view of the RDU120, showing its form factor and mounting bracket.
4.1 Front Panel Ports and Indicators
- Ethernet-port (RJ45): For 1 Gb network connectivity.
- USB-port: For local configuration or firmware updates.
- RS-485/232 Ports: For serial communication with compatible devices.
- Activity/Link LEDs: Indicate network activity and connection status.
5. Opsætning
5.1 Installationstrin
- Power Down Host Device: Ensure the Vertiv equipment where the RDU120 will be installed is completely powered off and unplugged.
- Locate IntelliSlot Bay: Identify the dedicated IntelliSlot bay on your Vertiv device.
- Insert RDU120 Card: Carefully slide the RDU120 Network Card into the IntelliSlot bay until it is fully seated. Ensure the front panel aligns with the device's chassis.
- Sikkert kort: Use any provided screws or retention clips to secure the card in place.
- Tilslut netværkskabel: Connect a standard Ethernet cable from your network switch or router to the Ethernet port on the RDU120 front panel.
- Power On Host Device: Reconnect power to the Vertiv equipment and power it on. The RDU120 will initialize with the host device.
5.2 Indledende konfiguration
Upon initial power-up, the RDU120 will typically obtain an IP address via DHCP. If DHCP is not available or a static IP is required, refer to the detailed configuration guide available on the Vertiv support webwebsted.
- Adgang til Web Interface: Åbn a web browser and enter the IP address of the RDU120. If DHCP is used, you may need to use a network scanner or the host device's interface to find the assigned IP.
- Standardlegitimationsoplysninger: Use the default username and password provided in the product documentation for initial login. Change these immediately for security.
- Netværksindstillinger: Configure static IP address, subnet mask, gateway, and DNS servers as per your network requirements.
6. Betjening
6.1 Web Interface Navigation
The RDU120's web interface provides comprehensive control and monitoring capabilities. Navigate through the menus to access various settings and data points.
- Dashboard: Giver en overview of system status, alarms, and key parameters.
- Overvågning: View real-time data, historical trends, and sensor readings.
- Konfiguration: Adjust network settings, user accounts, and communication protocols.
- Alarms & Notifications: Set up alarm thresholds and configure email/text message alerts.
6.2 Overvågningsdata
The RDU120 supports various protocols for data integration with Building Management Systems (BMS) and network monitoring tools.
- SNMP (Simple Network Management Protocol): Use SNMP v1/v2c/v3 for polling data and receiving traps. Refer to the MIB file for OID definitions.
- Modbus: Access data via Modbus TCP/IP. Consult the Modbus register map for details.
- BACnet: Integrate with BACnet/IP systems for building automation.
6.3 Alarm and Notification Management
Configure the RDU120 to send alerts for critical events:
- Define alarm thresholds for monitored parameters (e.g., temperature, voltagog).
- Configure email recipients and SMTP server settings for email notifications.
- Set up SMS gateway for text message alerts (if supported by your service provider).
6.4 Miljøovervågning
When connected to compatible Geist Sensors, the RDU120 can monitor environmental conditions:
- Temperatur og luftfugtighed: Monitor ambient conditions in server racks or rooms.
- Lækagedetektion: Detect water leaks to prevent equipment damage.
- Door Closures: Monitor access to cabinets or rooms.
7. Vedligeholdelse
7.1 firmwareopdateringer
Regularly check the Vertiv support webwebsted for de seneste firmwareopdateringer. Firmwareopdateringer kan give nye funktioner, forbedret ydeevne og sikkerhedsforbedringer.
- Download den relevante firmware file from the Vertiv webwebsted.
- Access the firmware update section in the RDU120 web interface.
- Follow the on-screen instructions to upload and install the firmware. Do not power off the device during the update process.
7.2 Systembackup og -gendannelse
It is recommended to back up the RDU120's configuration settings periodically, especially before major changes or firmware updates.
- Export configuration settings from the web interface.
- Store the backup file på et sikkert sted.
- Use the restore function to revert to a previous configuration if needed.
8. Fejlfinding
This section provides solutions to common issues you might encounter with the RDU120 Network Card.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Kan ikke få adgang web interface. | Incorrect IP address; Network connectivity issue; Firewall blocking access. | Verify IP address; Check network cable and switch; Disable temporary firewall for testing; Ensure RDU120 is powered on. |
| No data via SNMP/Modbus/BACnet. | Protocol not enabled; Incorrect configuration; Network routing issue. | Ensure protocol is enabled in RDU120 settings; Verify IP addresses and port numbers; Check network routes and firewalls. |
| Alarms not being sent. | Incorrect notification settings; SMTP server issues; Email address errors. | Verify alarm thresholds and notification recipients; Test SMTP server connectivity; Check spam folders. |
| Card not detected by host device. | Card not fully seated; Incompatible host device; Card malfunction. | Reseat the card firmly; Consult host device compatibility list; Contact Vertiv support if issue persists. |
For more complex issues, refer to the comprehensive troubleshooting guide on the Vertiv support website or contact Vertiv technical support.
9. Specifikationer
Technical specifications for the Vertiv Liebert IntelliSlot RDU120 Network Card:
| Attribut | Værdi |
|---|---|
| Produktdimensioner | 5.2 x 2.97 x 1.45 tommer |
| Varens vægt | 5.9 ounce |
| ASIN | B0F2MN6WTB |
| Varemodelnummer | RDU120 |
| Dato først tilgængelig | 27. marts 2025 |
| Fabrikant | Vertiv |
| Mærke | Vertiv |
| UPC | 767041039627 |
10. Garanti og support
10.1 Garantioplysninger
Vertiv products are backed by a standard limited warranty. For specific warranty terms and conditions applicable to your RDU120 Network Card, please refer to the warranty documentation included with your purchase or visit the official Vertiv webwebsted.
10.2 Teknisk support
For technical assistance, product inquiries, or troubleshooting beyond the scope of this manual, please contact Vertiv Technical Support. Support contact information can be found on the official Vertiv webwebsted:
Vertiv Official Webwebsted: www.vertiv.com
Please have your product model number (RDU120) and serial number ready when contacting support.