SUNGOLDPOWER SPLFP4012

SUNGOLDPOWER 4000W 12V Inverter Charger

Brugermanual

Model: SPLFP4012

1. Produktet er slutview

The SUNGOLDPOWER 4000W 12V Inverter Charger is a versatile power solution designed for off-grid systems, RVs, trailers, motorhomes, and backup power applications. It integrates an inverter, battery charger, and transfer switch into a single unit, providing reliable pure sine wave output suitable for sensitive electronics.

SUNGOLDPOWER 4000W 12V Inverter Charger

Figur 1.1: Forside view of the SUNGOLDPOWER 4000W 12V Inverter Charger.

Key features of this inverter charger include:

SUNGOLDPOWER Inverter Charger Features

Figur 1.2: Overview of key features including power ratings and output type.

2. Opsætning og installation

Before installation, ensure all components are present and undamaged. The package typically includes:

Included items with SUNGOLDPOWER Inverter Charger

Figure 2.1: Contents typically included in the product package.

2.1 Tilslutningsdiagram

Refer to the following diagram for proper connection of the inverter charger to your power system. Ensure all connections are secure and follow local electrical codes.

Connection Diagram for SUNGOLDPOWER Inverter Charger

Figure 2.2: Typical connection diagram showing utility power, generator, solar panel, battery bank, and home appliances.

2.2 Batteritilslutning

Connect the inverter charger to your battery bank using appropriate gauge wiring. This inverter supports a variety of battery types:

The inverter features multi-stage charging and a battery temperature sensor to protect your batteries from overheating and optimize charging performance.

Compatible Battery Types for SUNGOLDPOWER Inverter Charger

Figure 2.3: Visual representation of compatible battery types.

2.3 AC-indgangs- og udgangsforbindelser

The inverter charger accepts 220-240V AC input and provides 110-120V/220-240V split phase output. Ensure correct wiring for AC input from utility power or a generator, and AC output to your home or RV appliances. The unit includes two multi-functional AC output sockets.

Bag view of SUNGOLDPOWER Inverter Charger showing connections

Figur 2.4: Bagside view of the inverter charger, highlighting AC terminals and output protection.

3. Betjeningsvejledning

Once properly installed, the inverter charger can be operated via its integrated controls and the remote LCD display.

3.1 LCD Remote Controller

The remote LCD controller provides real-time data on battery voltage, input/output voltage, belastningsprocenttage, and operational status. Use the display to monitor the system's performance and adjust settings.

SUNGOLDPOWER Inverter Charger with LCD Remote Controller

Figure 3.1: The inverter charger unit with its remote LCD display.

3.2 DIP-switchindstillinger

The inverter charger features DIP switches for customizing various operational parameters, including:

Refer to the detailed instructions in the full user manual (PDF) for specific DIP switch configurations.

4. Vedligeholdelse

To ensure optimal performance and longevity of your SUNGOLDPOWER Inverter Charger, regular maintenance is recommended:

5. Fejlfinding

This section provides guidance for common issues. For detailed troubleshooting steps and error codes, please refer to the official Troubleshooting Guide PDF available for download.

Almindelige problemer og løsninger:

Download fejlfindingsvejledning (PDF)

6. Specifikationer

FeatureDetalje
ModelnavnSPLFP4012
Wattage4000 watt (kontinuerlig)
Peak Wattage12000 watts (for 20 seconds)
Input bindtage12V DC, 220-240V AC
Udgang Voltage110-120V/220-240V AC Split Phase
Output bølgeformRen Sine Wave
Batteriopladerstrøm120A
Transfer Switch Current30A
Produktdimensioner25.6 x 9.1 x 7.5 tommer
Varens vægt58.9 pund
FabrikantSUNGOLDPOWER

7. Garanti og support

SUNGOLDPOWER leverer en 12 måneders garanti for the 4000W 12V Inverter Charger, covering manufacturing defects and malfunctions under normal use. Additionally, lifetime technical service is provided by SUNGOLDPOWER, a professional manufacturer with over 10 years of experience in the inverter business.

For technical assistance, warranty claims, or any product-related inquiries, please contact SUNGOLDPOWER customer support through their official channels. Refer to the contact information provided in your product packaging or on the manufacturer's webwebsted.

Relaterede dokumenter - SPLFP4012

Preview Brugermanual til LFP-serien af ​​ren sinusbølge-inverter/oplader
Brugermanual til LFP-serien af ​​ren sinusbølgeinverter/oplader, med detaljerede sikkerhedsoplysninger, introduktion, installation, elektrisk ydeevne, fejlfinding og specifikationer.
Preview Brugermanual til SunGoldPower SPH-seriens alt-i-en solcelleladningsinverter
Omfattende brugermanual til SunGoldPower SPH-seriens alt-i-en solcelle-ladeinvertere, der dækker installation, drift, vedligeholdelse og tekniske specifikationer for modellerne SPH8K48SP og SPH10K48SP.
Preview Fejlfindingsvejledning til Sungoldpower Pure Sine Wave-inverteroplader
En omfattende fejlfindingsvejledning til Sungoldpower Pure Sine Wave-inverteropladere, der dækker almindelige problemer såsom unormale AC-aflæsninger, problemer med batteriopladning, udgangsfejl og ventilatordrift.
Preview SunGoldPower SPH302480A Alt-i-en solcelleladningsinverter brugermanual
Denne brugermanual indeholder omfattende instruktioner til SunGoldPower SPH302480A alt-i-en hybrid solcelle-opladningsinverteren, der dækker sikkerhed, installation, driftstilstande, LCD-skærmfunktioner, andre funktioner, beskyttelsesmekanismer, systemvedligeholdelse og detaljerede tekniske parametre.
Preview Sungoldpower SPH8K48SP / SPH10K48SP Alt-i-en solcelleladningsinverter brugermanual
Omfattende brugermanual til Sungoldpower SPH8K48SP og SPH10K48SP alt-i-en solcelle-ladeinverterne, der dækker sikkerhed, installation, drift, kommunikation, fejlfinding og tekniske specifikationer.
Preview Brugermanual til SunGoldPower energilagringssystem
Brugermanual til SunGoldPower energilagringssystem (ESS), der dækker installation, tilslutning, drift, vedligeholdelse og tekniske specifikationer for modellerne SGN7.6K1HB-48 og SGN11.4KHB-48.