1. Introduktion

The VOLTCRAFT VC121 PV Solar Energy Meter is a portable device designed for testing and evaluating solar panel performance. It measures key electrical parameters to help users assess the efficiency and functionality of photovoltaic systems. This meter supports a maximum power test of up to 800 W and features a large, backlit display that shows multiple measurement results simultaneously for clear readability.

Key features include automatic and manual measurement modes, an automatic backlight, and a Data Hold function for convenient evaluation. The device is equipped with MC4 solar panel connectors and an unlocking tool kit for easy integration into solar setups. It also provides warnings for overload and overheating conditions to ensure safe operation.

VOLTCRAFT VC121 PV Solar Energy Meter with MC4 connectors

Figure 1: The VOLTCRAFT VC121 PV Solar Energy Meter shown with its included MC4 connectors and test leads, ready for connection to a solar panel. The meter's display is visible, showing various measurement parameters.

2. Opsætning

2.1. Batteriinstallation

  1. Ensure the device is powered off and disconnect any test leads.
  2. Find batterirummet på bagsiden af ​​måleren.
  3. Åbn forsigtigt batterirummets dæksel. WARNING: To avoid electrical shock, remove test leads before opening the case.
  4. Insert a 9V (6F22) battery, observing the correct polarity (+/-).
  5. Luk batterirummets dæksel forsvarligt.
Tilbage view of VOLTCRAFT VC121 PV Solar Energy Meter

Figur 2: Bagside view of the VOLTCRAFT VC121 PV meter, showing the battery compartment cover and a warning label regarding electrical shock and opening the case.

2.2. Connecting to Solar Panels

  1. Ensure the solar panel is not generating power or is disconnected from any load.
  2. Connect the positive (+) MC4 connector from the solar panel to the positive input terminal on the meter.
  3. Connect the negative (-) MC4 connector from the solar panel to the negative input terminal on the meter.
  4. Ensure all connections are secure before proceeding with measurements.

3. Betjeningsvejledning

Front view of VOLTCRAFT VC121 PV Solar Energy Meter display

Figur 3: Nærbillede forfra view of the VOLTCRAFT VC121 PV meter, highlighting the display with various measurement parameters (Pmax, Vmp, Imp, Voc, Isc) and control buttons (HOLD, POWER, AUTO/MANUAL).

3.1. Tænd/sluk

  • Tryk på MAGT knappen for at tænde måleren.
  • Tryk og hold på MAGT button to turn the meter off.

3.2. Measurement Modes (Auto/Manual)

  • The meter supports both automatic and manual measurement modes.
  • Tryk på AUTO/MANUEL button to switch between modes. The display will indicate the currently active mode.
  • In Automatisk tilstand, the meter will continuously measure and update readings.
  • In Manuel tilstand, measurements are initiated by the user. The recommended test interval in Manual Mode is at least 30 seconds between measurements to ensure accurate readings and prevent overheating.

3.3. Aflæsning af displayet

The large, backlit display shows the following parameters:

  • Pmax: Maximum Power (in Watts)
  • Vmp: Voltage at Maximum Power (in Volts)
  • Imp: Current at Maximum Power (in Amperes)
  • Voc: Open Circuit Voltage (i volt)
  • Ise: Short Circuit Current (in Amperes)

3.4. Datahold-funktion

  • Tryk på HOLDE button to freeze the current readings on the display. This is useful for recording stable measurements.
  • Tryk på HOLDE button again to release the hold and resume live measurements.

3.5. Overload and Overheat Warnings

The meter is equipped with safety features to protect the device and the user:

  • Advarsel om overbelastning: If the input power exceeds the maximum capacity (800 W), an "Overload!" message will appear on the display. Disconnect the solar panel immediately to prevent damage.
  • Advarsel om overophedning: If the internal temperature of the device becomes too high, an overheat warning will be displayed. Allow the meter to cool down before resuming operation.

4. Vedligeholdelse

4.1. Rensning

  • Ensure the meter is powered off and disconnected from all solar panels and test leads before cleaning.
  • Tør ydersiden af ​​enheden af ​​med en blød, damp klæde. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Avoid getting moisture into the input terminals or any openings.

4.2. Udskiftning af batteri

When the battery indicator on the display shows low power, replace the 9V battery as described in the "Battery Installation" section (2.1). Always use a fresh 9V (6F22) battery.

4.3. Opbevaring

  • If storing the meter for an extended period, remove the battery to prevent leakage.
  • Opbevar enheden et køligt, tørt sted, væk fra direkte sollys og ekstreme temperaturer.

5. Fejlfinding

ProblemMulig årsagLøsning
Måleren tænder ikke.
  • Lavt eller dødt batteri.
  • Batteriet er sat forkert i.
  • Udskift 9V batteriet.
  • Kontroller batteriets polaritet, og sæt det korrekt i igen.
"Overload!" message displayed.
  • Input power exceeds 800 W.
  • Immediately disconnect the solar panel.
  • Ensure the solar panel's maximum power output is within the meter's specifications.
Overheat warning displayed.
  • Device internal temperature is too high.
  • Disconnect the solar panel and allow the meter to cool down in a well-ventilated area.
Unøjagtige eller ustabile aflæsninger.
  • Poor connection to solar panel.
  • Interferens fra andre elektriske apparater.
  • Measurement taken too quickly in Manual Mode.
  • Check and secure all MC4 connections.
  • Gå væk fra potentielle kilder til elektromagnetisk interferens.
  • Ensure at least 30 seconds between measurements in Manual Mode.

6. Specifikationer

MærkeVOLTCRAFT
ModelnummerVC121 PV (VC-16003655)
Maximum Power TestOp til 800 W
Maksimal voltage60 V MAKS
Dimensioner (L x B x H)4 x 7.6 x 15.7 cm
Vægt246 gram
Batteritype9V (6F22) battery (included)
ViseStort baggrundsbelyst display
StikMC4 solar panel connectors
SikkerhedsfunktionerOverload and overheat warnings
ASINB0DZS8NPBN
Date of Availability26. februar 2025
Side view of VOLTCRAFT VC121 PV Solar Energy Meter on its stand

Figur 4: Side view of the VOLTCRAFT VC121 PV meter, demonstrating its integrated kickstand for convenient viewunder drift.

7. Garanti og support

7.1. Garantioplysninger

Specific warranty details for the VOLTCRAFT VC121 PV Solar Energy Meter are not provided within this manual. Please refer to the manufacturer's official webwebstedet eller dit købssted for at få omfattende garantivilkår og -betingelser.

7.2. Teknisk support

For technical assistance, troubleshooting beyond the scope of this manual, or inquiries regarding spare parts, please contact VOLTCRAFT customer support directly. Contact information can typically be found on the VOLTCRAFT official webwebstedet eller på produktemballagen.

Relaterede dokumenter - VC121 PV

Preview VOLTCRAFT VC121 PV Solarmodul-Messgerät Bedienungsanleitung
Umfassende Bedienungsanleitung für das VOLTCRAFT VC121 PV Solarmodul-Messgerät. Enthält Informationen zur bestimmungsgemäßen Verwendung, Sicherheitshinweisen, Produktübersicht, Messverfahren og teknisk data für Solarpanel-Tests.
Preview VOLTCRAFT VC-513 80A AC/DC Stromzange Bedienungsanleitung
Umfassende Bedienungsanleitung für die VOLTCRAFT VC-513 80A AC/DC Stromzange. Erfahren Sie mehr über sichere Bedienung, Messverfahren für Strom, Spannung, Widerstand und mehr, sowie technische Spezifikationen.
Preview VOLTCRAFT Digitale Multimetre VC-7060BT & VC-7200BT Brugermanual
Omfattende brugermanual til VOLTCRAFT VC-7060BT og VC-7200BT digitale multimetre, der dækker sikkerhed, betjening, funktioner, målevejledninger, fejlfinding og tekniske specifikationer.
Preview VOLTCRAFT VC-CJS10 1200A Jumpstarter og Powerbank Brugermanual
Brugermanual til VOLTCRAFT VC-CJS10 1200A jumpstarter og powerbank. Lær om funktioner, tilsigtet anvendelse, sikkerhedsinstruktioner, betjening og tekniske specifikationer for starthjælpskøretøjer og ladeenheder.
Preview VOLTCRAFT VC-7060BT & VC-7200BT Digitalt Multimeter Lynguide
Omfattende hurtigguide til VOLTCRAFT VC-7060BT og VC-7200BT digitale multimetre. Lær om sikkerhed, betjening, målinger og fejlfinding.
Preview Voltcraft DT 8820 Multifunktionelt Miljømåleinstrument 4 i 1 Brugermanual
Omfattende brugermanual til Voltcraft DT 8820, et 4-i-1 multifunktionelt miljømåleinstrument. Dækker betjening, funktioner, sikkerhed og specifikationer for måling af lysintensitet, fugtighed, lydniveau og temperatur.