1. Introduktion
The Tzone PTD601 is an advanced USB RTD Temperature Data Logger designed for precise temperature monitoring across various applications. It features an intuitive interface, an external PT100 probe, and the ability to generate data reports directly via USB without requiring specialized software. This manual provides detailed instructions for the proper setup, operation, and maintenance of your PTD601 data logger.
2. Pakkens indhold
Kontroller venligst, at alle nedenstående varer er inkluderet i din pakke. Hvis der mangler eller er beskadigede varer, bedes du kontakte kundesupport.
- 1 x Tzone PTD601 Temperature Data Logger
- 1 x PT100 Temperature Probe (1.5m cable)
- 1 x USB-kabel
- 1 x Brugermanual (dette dokument)
- 1 x Temperature Calibration Certificate (if applicable)
- 1 x Portable Box (for storage and transport)

Figur 2.1: Contents of the Tzone PTD601 package, including the data logger, PT100 probe, USB cable, user manual, and portable box.
3. Produktfunktioner
- Bredt temperaturområde: Measures from -200℃ to 660℃ (-328℉ to 1220℉) with high accuracy.
- Høj nøjagtighed: ±(0.15+0.002*|t|)℃.
- Large Data Capacity: Stores up to 61,440 groups of data.
- Hurtig målehastighed: 1 measurement per second.
- Auto Reports: Generates TXT/CSV/XLS/PDF data reports automatically when connected to a computer, no software required.
- Stor LCD-skærm: Displays current, MAX, MIN, AVG temperature values, temperature trend chart, and recording quantity.
- External PT100 Probe: 1.5m long cable, suitable for diverse measurement scenarios. Supports PT100 and PT1000 probes.
- Multifunktionel: Features high and low temperature sound alarms, backlight function, auto-off to save battery, anti-slip design, foldable stand, and hanging design.
- Temperaturenheder: Supports ℃/℉/K switching.
- IP52 vandtæt rating: Provides protection against dust and dripping water.

Figur 3.1: The Tzone PTD601 displaying its backlight and data hold functions.
4. Opsætning
4.1 Batteriinstallation
The PTD601 is powered by 3x 1.5V AA batteries.
- Find batterirummet på bagsiden af enheden.
- Åbn batterirummets dæksel.
- Isæt tre 1.5V AA-batterier, og sørg for at polerne vender korrekt (+/-).
- Luk batterirummets dæksel forsvarligt.
4.2 Probetilslutning
Connect the PT100 temperature probe to the designated port on the top of the data logger. Ensure the connection is firm to prevent inaccurate readings.

Figur 4.1: The Tzone PTD601 data logger with the external PT100 probe inserted into test tubes for temperature measurement.
5. Betjening
5.1 Tænd/sluk
- For at tænde: Tryk og hold nede green power button until the LCD screen illuminates.
- For at slukke: Tryk og hold nede rød tænd/sluk-knap until the screen turns off. The device also features an auto-off function to conserve battery life.
5.2 Grundlæggende måling
Once powered on and the probe is connected, the device will immediately begin displaying real-time temperature readings on the large LCD screen.
- The screen shows current temperature, MAX/MIN/AVG values, and a temperature trend chart.
- Position the PT100 probe in the environment or substance you wish to measure.
5.3 Dataholdefunktion
To temporarily freeze the current temperature reading on the display, press the HOLDE button. Press it again to resume real-time measurements.
5.4 Baggrundsbelysningsfunktion
For operation in low-light conditions, press the Baggrundsbelysning button (often integrated with another function or a dedicated button, refer to device markings) to activate the screen backlight.
6. Parameterindstillinger
The PTD601 allows you to customize various settings through its menu system.

Figur 6.1: The Tzone PTD601 displaying its menu for parameter settings, including Sensor Type, Sound, Logging, Auto Off, and Alert.
- Tryk på Menu button (often labeled with an 'M' or similar icon) to enter the settings menu.
- Use the navigation buttons (up/down arrows or similar) to scroll through options such as:
- Sensortype: Select between PT100 or PT1000 if applicable.
- Sund: Aktivér eller deaktiver hørbare alarmer.
- Logning: Configure data logging intervals or start/stop logging.
- Auto slukket: Juster den automatiske sluk-timer.
- Alert: Indstil alarmtærskler for høj og lav temperatur.
- Temperaturenheder: Switch between Celsius (℃), Fahrenheit (℉), or Kelvin (K) using the dedicated ℃/℉/K button or within the menu.
- Tryk på Indtast button to confirm selections or the Udgang knappen for at forlade menuen.
7. Data Management (Auto Reports)
One of the key features of the PTD601 is its ability to generate data reports without requiring proprietary software.
- Ensure the data logger has recorded data.
- Connect the PTD601 to a computer using the provided USB cable.
- The device will be recognized as a removable storage device.
- Navigate to the device's storage. You will find automatically generated data reports in TXT, CSV, XLS, and PDF formats.
- Åbn disse files til view or analyze your temperature data.
- The device also supports a "regenerate file" function for recovering recent records or deleted data. Refer to the on-screen prompts or the device's internal menu for this option.

Figur 7.1: The Tzone PTD601 connected to a computer, demonstrating the automatic generation of data reports in various formats (TXT, CSV, XLS, PDF) without requiring software installation.
8. Alarmer
The PTD601 features configurable high and low temperature sound alarms to alert users when temperatures exceed or fall below set thresholds.
- Access the "Alert" option within the Parameter Settings menu (refer to Section 6).
- Set your desired high temperature limit.
- Set your desired low temperature limit.
- Ensure the "Sound" option is enabled in the settings if you wish to receive audible alerts.
- When the measured temperature crosses these thresholds, an audible alarm will sound, and an alert icon may appear on the display.

Figur 8.1: The Tzone PTD601 indicating a high or low temperature alarm condition with an audible alert.
9. Vedligeholdelse
9.1 Rengøring
To clean the device, wipe it with a clean, damp cloth. Do not use abrasive cleaners or immerse the device in water. Ensure the probe is clean before and after each use, especially when measuring different substances.
9.2 Udskiftning af batteri
When the battery indicator on the LCD screen shows low power, replace the 1.5V AA batteries as described in Section 4.1. Remove batteries if the device will not be used for an extended period to prevent leakage.
9.3 Opbevaring
Store the PTD601 in its portable box in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature (without battery) is -20℃ to 60℃.
10. Fejlfinding
If you encounter issues with your Tzone PTD601, refer to the following common problems and solutions:
- Enheden tændes ikke:
- Kontroller batteriinstallationen og sørg for korrekt polaritet.
- Replace with fresh 1.5V AA batteries.
- Sørg for, at tænd/sluk-knappen holdes tilstrækkeligt nede.
- Unøjagtige temperaturaflæsninger:
- Ensure the PT100 probe is securely connected.
- Verify the probe is fully immersed or properly positioned in the measurement area.
- Check for any physical damage to the probe or cable.
- Consider recalibration if accuracy issues persist (refer to calibration certificate or contact support).
- No data report generated via USB:
- Ensure the device is powered on and connected correctly to the computer's USB port.
- Prøv en anden USB-port eller et andet kabel.
- Verify that the device's internal memory is not full.
- Restart the computer and reconnect the device.
- Alarmen lyder ikke:
- Check the "Sound" setting in the menu to ensure it is enabled.
- Verify that the high and low alarm thresholds are set correctly and that the current temperature is outside these limits.
For issues not covered here, please contact Tzone customer support.
11. Specifikationer

Figur 11.1: Detailed specifications and physical dimensions of the Tzone PTD601 data logger and its probe.
| Feature | Specifikation |
|---|---|
| Modelnummer | PTD601 |
| Sensortype | PT100 (-200℃~660℃), PT1000 (-50℃~300℃) |
| Standard Sensor Measurement Range | -160℃ to 300℃ (with included probe) |
| Nøjagtighed | ±(0.15+0.002*|t|)℃ |
| Temperaturenheder | ℃ / ℉ / K |
| Opløsning | 0.1 |
| Målehastighed | 1 sekund/gang |
| Datakapacitet | 61,440 Grupper |
| Beskyttelsesgrad | IP52 |
| Dimensioner | 183 x 83 x 35 mm |
| Vægt | 295g (excluding probe) |
| Probekabellængde | 1.5m |
| Strømkilde | 3*1.5V AA batterier |
| Driftstemperatur | -10℃ til 50℃ |
| Opbevaringstemperatur | -20℃ to 60℃ (without battery) |
| Forbindelse | USB |
| Særlige funktioner | Alarm, Auto Off, Backlit, Fast Refresh, High Accuracy |
| Certificeringer | CE |
12. Ansøgninger
The Tzone PTD601 Temperature Data Logger is suitable for a wide range of professional and industrial applications requiring accurate and reliable temperature monitoring.
- Laboratorium: Monitoring chemical reactions, sample storage, and environmental conditions.
- Engineering: HVAC system analysis, process control, and equipment performance testing.
- Industriel produktion: Quality control, environmental monitoring in manufacturing processes.
- Freezer/Cold Chain: Ensuring proper temperature for perishable goods storage and transportation.
- Forskning og udvikling: Data collection for experimental setups.

Figur 12.1: Examples of the Tzone PTD601 in use across various applications, including industrial settings, laboratories, and freezers.
13. Garanti og support
13.1 Garantioplysninger
Tzone products are manufactured to high-quality standards. For specific warranty details, please refer to the warranty card included with your product or visit the official Tzone webGarantien dækker typisk defekter i materialer og udførelse under normal brug.
13.2 Kundesupport
If you require technical assistance, have questions about your product, or need to report a defect, please contact Tzone customer support.
- Webwebsted: Visit the official Tzone webwebsted med ofte stillede spørgsmål, supportressourcer og kontaktoplysninger.
- E-mail/Telefon: Refer to the contact details provided in your product packaging or on the Tzone webwebsted.
Please have your product model number (PTD601) and purchase information ready when contacting support.