1. Produktet er slutview

The ALORAIR Storm 80X is a commercial-grade dehumidifier designed for efficient moisture removal in large spaces up to 2,100 square feet. It is capable of removing up to 170 pints of water per day at saturation (90°F, 90% RH) and 80 PPD at AHAM conditions. This unit features a robust rotomolded housing for durability, a built-in condensate pump for continuous drainage, and an intuitive control panel for easy operation.

ALORAIR Storm 80X Commercial Dehumidifier

Figure 1: ALORAIR Storm 80X Dehumidifier with retractable handle.

Nøglefunktioner:

2. Vigtige sikkerhedsoplysninger

Read all instructions carefully before operating the dehumidifier. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Opsætning og installation

3.1 Udpakning af enheden

Carefully remove the dehumidifier from its packaging. Inspect the unit for any signs of damage during transit. Retain packaging materials for future storage or transport.

Video 1: Unboxing and initial setup of the ALORAIR Storm 80X Dehumidifier.

3.2 Montering af håndtag

The retractable handle is designed for easy mobility. To extend the handle, loosen the two knobs on the sides, pull the handle upwards, and then tighten the knobs to secure it in place. To retract, reverse the process.

Person pulling ALORAIR Storm 80X Dehumidifier with handle and wheels

Figure 2: The retractable handle and large wheels facilitate easy movement of the unit.

3.3 Afløbsslangetilslutning

Connect the provided 19.6 ft drain hose to the quick-connect fitting at the bottom rear of the unit. Ensure a secure connection to prevent leaks. Route the hose to a suitable drainage point, such as a floor drain or sink, ensuring the hose is not kinked or obstructed. The built-in pump can lift water up to 19.6 feet vertically.

ALORAIR Storm 80X Dehumidifier with drain hose and pump drainage height indicated

Figure 3: Drain hose connection and pump drainage height capability.

3.4 Strømtilslutning

Plug the dehumidifier into a standard 115V grounded electrical outlet. The power cord can be neatly coiled and stored on the back of the unit when not in use or for transport.

ALORAIR Storm 80X Dehumidifier showing convenient cord and hose storage on the back

Figur 4: Bagside view of the dehumidifier showing integrated cord and hose storage.

4. Betjeningsvejledning

4.1 Kontrolpanel overview

The Storm 80X features an intelligent touch control panel. It displays real-time inlet and outlet temperature, humidity, job hours, and total life hours. Buttons include Power, Purge, Menu, and Set.

Close-up of ALORAIR Storm 80X control panel showing display and buttons

Figur 5: Detaljeret view of the intelligent touch control panel.

Video 2: Demonstration of the control panel and its functions.

4.2 Indstilling af ønsket luftfugtighed

  1. Press the 'Set' button to enter humidity adjustment mode.
  2. Use the arrow buttons to increase or decrease the desired humidity percentage (25% til 80%).
  3. Enheden vil automatisk fungere for at opretholde det indstillede fugtighedsniveau.

4.3 Kontinuerlig tilstand

To operate the dehumidifier continuously, set the humidity level to 'CO%' (Continuous Mode) using the 'Set' and arrow buttons. In this mode, the unit will run constantly, removing moisture without stopping based on a set humidity level.

4.4 Automatiske funktioner

5. Vedligeholdelse

Regular maintenance ensures optimal performance and extends the lifespan of your ALORAIR Storm 80X dehumidifier.

5.1 MERV-1 Filter Cleaning/Replacement

The unit is equipped with a washable MERV-1 filter. It is recommended to clean the filter every three months or more frequently depending on usage and environment. Replace the filter after two cleanings or as needed.

  1. Afbryd strømmen til enheden.
  2. Locate the filter access panel on the front of the unit.
  3. Fjern filteret.
  4. Clean the filter with warm water and mild detergent, or vacuum it. Allow it to dry completely before reinstallation.
  5. Reinsert the clean filter and secure the access panel.

Video 3: Instructions for replacing the MERV-1 filter.

5.2 Drain System Maintenance

Periodically check the drain hose for any blockages or kinks. Ensure the condensate pump is functioning correctly by observing water flow during operation. The 'Purge' button on the control panel can be used to manually activate the pump and clear any residual water.

6. Fejlfinding

If the unit is not operating correctly, refer to the following common issues before contacting support.

ProblemMulig årsagLøsning
Enheden tænder ikkeNo power, power cord disconnected, circuit breaker tripped.Kontroller strømforbindelsen, sørg for at stikkontakten fungerer, nulstil afbryderen.
Ingen affugtningHumidity setting too high, filter clogged, room temperature too low.Lower humidity setpoint, clean/replace filter, ensure room temperature is within operating range (35.6°F - 102.2°F).
VandlækageDrain hose kinked or clogged, drain connection loose.Inspect and clear drain hose, ensure secure connection.
Enheden er støjendeEnheden står ikke på en plan overflade, ventilatorblokering.Place unit on a level surface, check for and remove any obstructions.
Fejlkode på displayInternal malfunction detected.Refer to the full user manual for specific error code definitions or contact customer support.

7. Specifikationer

FeatureSpecifikation
MærkeALORAIR
ModelnavnStorm 80X
Affugtningskapacitet (mætning)170 pints om dagen
Affugtningskapacitet (AHAM)80 PPD
DækningsområdeOp til 2,100 kvadratmeter
Luftmængde kapacitet200 kubikfod pr. minut (CFM)
Driftstemperaturområde35.6°F - 102.2°F
Driftsfugtighedsområde25% - 80% RF
Strømforbrug607 watt
Produktmål (L×B×H)15.2" D x 14.4" B x 24.8" H
Varens vægt63.9 pund
Afløbsslange længde19.6 fod
Afløbets vertikale højde19.6 fod
FiltertypeMERV-1
CertificeringerETL opført

8. Garanti og support

ALORAIR provides a comprehensive warranty for the Storm 80X dehumidifier:

For additional warranty information or technical support, please refer to the full product user manual or contact ALORAIR customer service.

Relaterede dokumenter - Storm 80X

Preview ALORAIR Storm DP Dehumidifier Owner's Manual - Operation, Features, Specifications, and Maintenance
Comprehensive owner's manual for the ALORAIR Storm DP Dehumidifier. This guide covers product features, detailed specifications, operating instructions, troubleshooting common issues, and maintenance procedures for optimal performance.
Preview AlorAir Galaxy 85P Dehumidifier: Features, Specifications, and Applications
Discover the AlorAir Galaxy 85P Dehumidifier, a powerful and compact solution for moisture control in residential and commercial spaces. Learn about its features, specifications, performance, and applications.
Preview Installations- og betjeningsmanual til AlorAir Storm-affugter
Denne manual indeholder detaljerede instruktioner til AlorAir Storm SLGR 850X, Storm LGR 850X og Storm LGR 850 affugtere, der dækker sikkerhed, betjening, vedligeholdelse, fejlfinding og garantioplysninger.
Preview Alorair Storm LGR Extreme affugter: Installations- og betjeningsmanual
Omfattende guide til Alorair Storm LGR Extreme affugteren, der dækker installation, betjening, vedligeholdelse, fejlfinding, fejlkoder og garantioplysninger.
Preview AlorAir Storm SLGR 1250X installations- og betjeningsmanual
Denne manual indeholder omfattende vejledning i installation, drift, vedligeholdelse og fejlfinding af AlorAir Storm SLGR 1250X affugteren. Den dækker sikkerhedsinstruktioner, strømforsyning, enhedens funktionalitet, identifikation af dele, brug af LCD-displayet og garantioplysninger.
Preview ALORAIR Storm DP Dehumidifier Owner's Manual - Features, Specs, Operation & Maintenance
Comprehensive owner's manual for the ALORAIR Storm DP Dehumidifier. Covers features, specifications, operation guidelines, troubleshooting, maintenance procedures, and limited warranty information.