FireAngel SW1-R

FireAngel SW1-R Netdrevet Optisk Røgalarm Brugermanual

Model: SW1-R

1. Produktet er slutview

The FireAngel SW1-R is a mains-powered optical smoke alarm designed to provide early warning of fire. It features a 9V backup battery to ensure continuous protection during power outages. The alarm emits a loud 85dB sound at 3 meters and includes LED visual indicators for clear alerts.

This optical smoke alarm is particularly effective at detecting slow-burning fires that produce thick white smoke, making it suitable for general living areas.

Nøglefunktioner:

FireAngel SW1-R Smoke Alarm front view

Figur 1: Forside view of the FireAngel SW1-R Mains Powered Optical Smoke Alarm.

FireAngel SW1-R Smoke Alarm with packaging and key features

Figure 2: FireAngel SW1-R Smoke Alarm highlighting its 9V backup battery, audible/visual alerts, and large test button.

2. Vigtige sikkerhedsoplysninger

Læs venligst alle instruktioner omhyggeligt før installation og betjening. Gem denne manual til senere brug.

FireAngel SW1-R Smoke Alarm placement guidelines

Figure 3: Illustration of recommended placement guidelines for the smoke alarm, showing distance from walls and light fittings, and unsuitable locations.

3. Pakkens indhold

Kontroller, at alle varer er til stede og ubeskadigede, når du åbner pakken:

4. Installationsvejledning

Vigtig: Installation should only be performed by a competent person or qualified electrician. Ensure the mains power supply is switched off at the consumer unit before commencing installation.

4.1. Trin før installation:

  1. Vælg placering: Choose a suitable location on the ceiling, adhering to the placement guidelines (refer to Section 2).
  2. Afbryd strømmen: Turn off the mains electricity supply to the circuit where the alarm will be installed.
  3. Installer backupbatteri: Open the battery compartment on the alarm unit and insert the supplied 9V battery, observing polarity. Close the compartment securely.

4.2. Mounting the Alarm:

  1. Markér borepunkter: Hold the base plate against the ceiling at your chosen location and mark the two drilling points.
  2. Bore huller: Drill holes at the marked points and insert the rawl plugs.
  3. Monter bundplade: Secure the base plate to the ceiling using the provided screws.
  4. Tilslut ledninger: Connect the mains wiring (Live, Neutral, Earth, and Interlink if applicable) to the terminal block provided. Ensure connections are secure and correct. The alarm unit connects to this terminal block.
  5. Attach Alarm Unit: Align the smoke alarm unit with the base plate and twist clockwise until it clicks securely into place.
FireAngel SW1-R Smoke Alarm easy installation steps

Figure 4: Visual guide for easy installation, showing steps like installing the backup battery, mounting the bracket, attaching the alarm, and connecting to mains power.

4.3. Interlinking Multiple Alarms:

The SW1-R can be hardwired and interconnected with up to 12 compatible FireAngel mains-powered smoke (SW1), heat (HW1), or carbon monoxide (CW1) alarms. To interlink, connect the interlink wire between the designated terminals on each alarm's base plate. When one interlinked alarm detects a hazard, all connected alarms will sound simultaneously.

4.4. Post-Installation Check:

  1. Gendan strøm: Turn the mains electricity supply back on.
  2. Test alarm: Press and hold the Test/Silence button for 5 seconds to confirm the alarm is functioning correctly. A loud, high-pitched sound indicates proper operation.

5. Betjeningsvejledning

5.1. Normal drift:

Under normal conditions, the alarm will periodically flash its LED indicator to show it is powered and monitoring for smoke. If smoke is detected, the alarm will sound a loud siren and the LED will flash rapidly.

5.2. Test/Silence Button:

5.3. Sleep Easy Function:

If the 9V backup battery is low, the alarm will emit a regular "chirp" sound. To temporarily silence these low battery chirps for up to 8 hours, press the Test/Silence button. This allows for an uninterrupted night's sleep while still maintaining protection. Replace the battery as soon as possible after using this function.

6. Vedligeholdelse

Regular maintenance ensures the continued reliability and effectiveness of your smoke alarm.

FireAngel SW1-R Smoke Alarm maintenance tips

Figure 5: Visual summary of key maintenance recommendations for the smoke alarm, including monthly testing and quarterly vacuuming.

7. Fejlfinding

If your smoke alarm is not operating as expected, refer to the following table for common issues and solutions:

ProblemMulig årsagLøsning
Alarm chirps intermittentlyLow 9V backup battery.Replace the 9V battery immediately. Use the Sleep Easy function if needed for temporary silence.
Alarm sounds without visible smoke (false alarm)Dust or debris in the sensing chamber; high humidity; cooking fumes; steam.Press the Test/Silence button to temporarily silence. Vacuum the alarm thoroughly. Relocate the alarm if it's consistently affected by cooking fumes or steam.
Alarmen lyder ikke under testenNo mains power; flat 9V backup battery; faulty unit.Check mains power supply. Replace 9V battery. If problem persists, contact customer support.
Interlinked alarms do not all soundFaulty interlink wiring; incompatible alarms; too many alarms interlinked.Check interlink wiring connections. Ensure all interlinked alarms are compatible FireAngel models. Do not exceed 12 interlinked alarms.

8. Tekniske specifikationer

ModelnummerSW1-R
SensortypeOptisk (fotoelektrisk)
StrømkildeMains Powered (230V AC) with 9V DC Battery Backup
Alarmvolumen85dB ved 3 meter
Interlink CapabilityUp to 12 compatible FireAngel mains-powered alarms
Produktmål (D x B x H)4.2D x 12.6B x 12.6H Centimeter
Varens vægt220 gram
DriftstemperaturSe produktemballagen for specifikt sortiment
FugtighedsområdeSe produktemballagen for specifikt sortiment
StandarderBS EN 14604:2005
UPC816317004422
FireAngel SW1-R Smoke Alarm with UKCA and CE marks

Figure 6: The FireAngel SW1-R Smoke Alarm displaying its UKCA and CE certifications, indicating compliance with safety standards.

9. Garanti og kundesupport

9.1. Garantioplysninger:

The FireAngel SW1-R Mains Smoke Alarm comes with a 5 års garanti fra købsdatoen. Denne garanti dækker materiale- og fabrikationsfejl ved normal brug. Gem venligst din købsbevis i tilfælde af garantikrav.

The warranty does not cover damage caused by misuse, accidental damage, unauthorized modifications, or failure to follow the instructions in this manual.

9.2. Kundesupport:

For technical assistance, warranty claims, or further information regarding your FireAngel SW1-R smoke alarm, please contact FireAngel customer support. Refer to the FireAngel official webwebstedet eller produktemballagen for de mest opdaterede kontaktoplysninger.

Webwebsted: www.fireangel.co.uk (Eksamp(linket, det faktiske link kan variere fra region til region)

Relaterede dokumenter - SW1-R

Preview FireAngel HW1 Mains Powered Heat Alarm User Manual
Comprehensive user manual for the FireAngel HW1 Mains Powered Heat Alarm with 9V battery backup. Includes installation, positioning, silencing features, interconnecting options, maintenance, troubleshooting, and warranty information.
Preview FireAngel Røg- og Varmealarm Brugermanual: FA6611, FA6615, FA6620, FA6720
Omfattende brugermanual til FireAngel FA6611, FA6615, FA6620 optiske røgalarmer og FA6720 varmealarm. Dækker installation, vedligeholdelse, fejlfinding, garanti og bortskaffelse.
Preview FireAngel ST-625-INT Røgalarm Brugermanual
Omfattende brugermanual til FireAngel ST-625-INT røgalarmen, der dækker installation, funktioner, vedligeholdelse og garanti. Denne vejledning indeholder vigtige sikkerhedsoplysninger og betjeningsinstruktioner.
Preview FireAngel SCB10 Kombination af røg- og kuliltealarm brugermanual
Brugermanual til FireAngel SCB10, en kombineret røg- og kuliltealarm, der indeholder omfattende instruktioner om installation, betjening, vedligeholdelse og sikkerhed til brug i private hjem.
Preview FireAngel Røg- og Varmealarm Brugermanual: FA6611, FA6615, FA6620, FA6720
Brugermanual til FireAngel optiske røgalarmer (FA6611, FA6615, FA6620) og varmealarmer (FA6720). Indeholder detaljerede oplysninger om placering, installation, vedligeholdelse, fejlfinding, lydløshed og "sleep easy"-funktioner, garanti og bortskaffelsesinstruktioner for at sikre brandsikkerhed i hjemmet.
Preview FireAngel SM-SN-1 and HM-SN-1 Mains Powered Smoke and Heat Alarm Installation and User Guide
Comprehensive guide for installing and using FireAngel SM-SN-1 (Mains Powered Smoke Alarm) and HM-SN-1 (Mains Powered Heat Alarm). Covers system grades, positioning, hardwire and wireless interlinking, alarm testing, smart silence features, troubleshooting, maintenance, and warranty information.