The SilverStone RM45-360 is a versatile 4U rackmount chassis designed for server and workstation applications. It features a flexible front panel layout, allowing for customization to meet various system requirements. This manual provides detailed instructions for the installation, operation, and maintenance of your RM45-360 chassis.
Please read this manual thoroughly before beginning installation to ensure proper setup and to maximize the performance and longevity of your system.
2. Nøglefunktioner
- Supports SSI-EEB, SSI-CEB, E-ATX, ATX, Micro-ATX, and Mini-ITX motherboards.
- Supports ATX (PS2), 2U Redundant, and Mini Redundant power supplies.
- Accommodates up to 8 x 3.5" HDDs, 4 x 2.5" SSDs, and 8 expansion slots.
- Supports a 360mm radiator for advanced cooling solutions.
- Optional front panel kits available for configuring to different configurations.
- Flexible front panel design with convertible 5.25" device bays.
Figur 2.1: Vinklet front view of the SilverStone RM45-360 chassis, showcasing its rackmount handles and front panel design.
Figur 2.2: Direkte front view of the chassis, highlighting the ventilation grilles and front I/O ports.
Figur 2.3: Side view of the chassis, showing the overall dimensions and rackmount form factor.
Figur 2.4: Bagside view of the chassis, detailing the power supply cutout, expansion slots, and rear fan mounts.
Figur 2.5: Detaljeret view of the eight standard-height PCI expansion slots, allowing for multi-GPU or specialized card configurations.
Figur 2.6: Intern view showing the pre-installed 80mm fans at the rear of the chassis, designed for exhaust airflow.
Figure 2.7: Close-up of the front panel I/O, including USB 3.0 ports, power/reset buttons, and LED indicators for power and drive activity.
Figure 2.8: Diagram illustrating the internal layout, showing locations for motherboard, drives, and cooling components.
Figure 2.9: Detailed diagram of the front panel I/O, labeling USB 3.0, power/reset buttons, LED indicators, and USB Type-C port.
Figure 2.10: Cooling support diagram, indicating locations for 80mm fans, 120mm fan support, and radiator support (360mm, 240mm, 120mm).
Figure 2.11: Storage support diagram, detailing the 3.5" HDD cage (4x 3.5" HDD, 1x 2.5" SSD) and 2x 2.5" SSD mounts.
3. Opsætning og installation
Before beginning installation, ensure you have all necessary components and tools. Always handle components with care and follow anti-static precautions.
3.1. Installation af bundkort
- Remove the top cover of the chassis by unscrewing the retaining screws.
- Install the appropriate motherboard standoffs for your motherboard form factor (SSI-EEB, SSI-CEB, E-ATX, ATX, Micro-ATX, Mini-ITX).
- Carefully place the motherboard into the chassis, aligning it with the standoffs and the I/O shield opening.
- Fastgør bundkortet med skruer.
3.2. Installation af strømforsyning
- Identify the power supply mounting area at the rear of the chassis.
- Slide the ATX (PS2), 2U Redundant, or Mini Redundant power supply into its designated bay.
- Secure the power supply with screws from the rear of the chassis.
3.3. Drevinstallation (HDD/SSD)
- 3.5" harddiske: Utilize the provided drive cages. Slide the HDDs into the trays and secure them with screws. Insert the filled trays into the drive cage bays.
- 2.5" SSD'er: Mount SSDs to the designated 2.5" SSD mounts or use adapters for 3.5" bays if needed.
- Connect SATA data and power cables to all installed drives.
3.4. Installation af udvidelseskort
- Remove the necessary PCI slot covers from the rear of the chassis.
- Insert your expansion cards (e.g., graphics cards, network cards) into the corresponding motherboard PCI-E slots.
- Secure the expansion cards with the retaining screws or clips.
3.5. Cooling System Installation (Fans/Radiator)
- Front Fans/Radiator: The front bay supports up to a 360mm radiator or multiple fans. Install fans or radiator onto the removable bracket and then secure the bracket into the chassis.
- Rear Fans: The chassis comes with pre-installed 80mm rear fans. Ensure they are properly connected to the motherboard or fan controller.
- Connect all fan power cables to appropriate headers.
3.6. Kabelforvaltning
Route all cables neatly to ensure optimal airflow and ease of future maintenance. Use cable ties or Velcro straps to bundle cables together.
4. Betjening
4.1. Tænd/sluk
- Tænd: Ensure all components are correctly installed and connected. Connect the power cable to the power supply and a wall outlet. Press the power button on the front panel.
- Sluk: Perform a graceful shutdown through your operating system. Alternatively, press and hold the power button for several seconds for a forced shutdown (use only when necessary).
4.2. Betjeningselementer og indikatorer på frontpanelet
- Power knap: Initiates system power on/off.
- Nulstil knap: Genstarter systemet.
- Power LED: Illuminates when the system is powered on.
- HDD Activity LED: Flashes to indicate hard drive activity.
- USB 3.0-porte: Til tilslutning af USB 3.0-kompatible enheder.
- USB Type-C-port: For connecting USB Type-C compatible devices.
5. Vedligeholdelse
Regular maintenance helps ensure the longevity and optimal performance of your RM45-360 chassis and the components within it.
- Fjernelse af støv: Rengør støvfiltre og interne komponenter regelmæssigt med trykluft. Sørg for, at systemet er slukket og taget ud af stikket, før rengøring.
- Kabelhåndteringstjek: Verify that all cables are securely connected and not obstructing airflow.
- Ventilator inspektion: Check fans for dust buildup and ensure they are spinning freely. Replace any noisy or malfunctioning fans.
- Miljøforhold: Ensure the chassis is operated in a well-ventilated area, free from excessive heat, humidity, and dust.
6. Fejlfinding
Dette afsnit indeholder løsninger på almindelige problemer, du kan støde på.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Systemet tænder ikke. | Power cable disconnected, PSU switch off, faulty PSU, loose front panel connector. | Check power cable connection. Ensure PSU switch is ON. Verify front panel power button connector is securely attached to motherboard. Test with a known good PSU if possible. |
| Fans are not spinning. | Fan cables disconnected, faulty fan, insufficient power. | Check fan cable connections to motherboard or fan controller. Ensure fans are not obstructed. Replace faulty fans. |
| Ingen skærmudgang. | Graphics card not seated properly, monitor cable disconnected, faulty GPU/monitor. | Reseat graphics card. Check monitor cable connections. Test with another monitor or graphics card if available. |
| System overophedning. | Poor airflow, dust buildup, fan malfunction. | Ensure proper fan configuration and clean dust filters. Verify all fans are operational. Improve cable management for better airflow. |
7. Tekniske specifikationer
| Feature | Detalje |
|---|---|
| Mærke | Sølvsten |
| Modelnavn | RM45-360 |
| Varemodelnummer | SST-RM45-360 |
| Formfaktor | 4U Rackmount |
| Bundkort kompatibilitet | SSI-EEB, SSI-CEB, E-ATX, ATX, Micro-ATX, Mini-ITX |
| Understøttelse af strømforsyning | ATX (PS2), 2U Redundant, Mini Redundant |
| 3.5" drevbåse | Op til 8 |
| 2.5" drevbåse | Op til 4 |
| Udvidelsesslots | 8 (Standard Height) |
| Radiatorstøtte | Up to 360mm (front) |
| Forudinstallerede ventilatorer | 2 x 80mm (rear) |
| Front I / O-porte | 2 x USB 3.0, 1 x USB Type-C, Power Button, Reset Button, Power LED, HDD Activity LED |
| Materiale | Metal |
| Farve | Sølv |
| Produktmål (LxBxH) | 19.69 x 17.24 x 6.93 tommer (500 x 438 x 176 mm) |
| Varens vægt | 33.4 pund (15.15 kg) |
8. Garanti og support
8.1. Garantioplysninger
SilverStone Technology products are designed and manufactured to the highest quality standards. For specific warranty terms and conditions applicable to your RM45-360 chassis, please refer to the warranty card included with your product or visit the official SilverStone Technology webwebsted.
Gem venligst dit købsbevis for garantikrav.
8.2. Teknisk support
If you encounter any issues or have questions regarding the SilverStone RM45-360 chassis that are not covered in this manual, please contact SilverStone Technology customer support.
- Online support: Visit the official SilverStone Technology webwebsted med ofte stillede spørgsmål, drivere og supportressourcer.
- Kontaktoplysninger: Refer to the SilverStone webwebsted for regionale kontaktoplysninger (telefon, e-mail).
For de mest opdaterede supportoplysninger, besøg venligst www.silverstonetek.com.