1. Introduktion
This manual provides detailed instructions for the KAIWEETS HT206D Digital Clamp Meter and the KAIWEETS 0.8V-100V DC Smart Automotive Test Light. These instruments are designed for accurate electrical measurements and automotive circuit testing, suitable for professional and household use. Please read this manual thoroughly before operation to ensure safe and correct usage.

Image 1.1: KAIWEETS HT206D Digital Clamp Meter and KAIWEETS 0.8V-100V DC Smart Automotive Test Light.
This image displays both the KAIWEETS HT206D Digital Clamp Meter (left) and the KAIWEETS 0.8V-100V DC Smart Automotive Test Light (right). The clamp meter is red and black with a digital display and rotary dial. The test light is black with a digital display, probe, and alligator clip.
2. Sikkerhedsoplysninger
Always adhere to basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, or personal injury. Keep this manual for future reference.
- Overskrid ikke de maksimale inputværdier, der er angivet for hver funktion.
- Udvis ekstrem forsigtighed, når du arbejder med voltagover 30V AC RMS, 42V peak eller 60V DC. Disse voluminertages udgør en stødfare.
- Before measuring current, ensure the instrument is properly set up and the test leads are correctly connected.
- Frakobl altid testledningerne fra kredsløbet, før du ændrer funktioner eller områder.
- Inspect the test leads for damaged insulation or exposed metal before use. Replace if damaged.
- Do not operate the instrument if it appears damaged or if it is not functioning properly.
- Sørg for, at batteridækslet er forsvarligt lukket før brug.
- Use caution when working in wet environments.
- For current measurement with the clamp meter, clamp around only one wire, not the entire power cord, to obtain an accurate reading.
3. Produktkomponenter
3.1 KAIWEETS HT206D Digital Clamp Måler

Image 3.1: KAIWEETS HT206D Digital Clamp Måler og medfølgende tilbehør.
This image shows the KAIWEETS HT206D Digital Clamp Meter along with its accessories: two 1.5V AA batteries, red and black test leads, a K-type thermocouple, and a carrying case.
KAIWEETS HT206D Digital Clamp Måleren inkluderer:
- Digital Clamp Målerenhed
- Testledninger (røde og sorte)
- K-type termoelement
- Bæretaske
- Brugervejledning (dette dokument)
- Batteries (typically 2x AA or AAA, check packaging for exact type)
3.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
The KAIWEETS 0.8V-100V DC Smart Automotive Test Light includes:
- Smart Automotive Test Light unit with coiled cable and alligator clip
- Brugervejledning (dette dokument)
4. Opsætning
4.1 KAIWEETS HT206D Digital Clamp Meter Battery Installation
- Locate the battery compartment on the back of the clamp måler.
- Brug en skruetrækker til at åbne batteridækslet.
- Insert the specified batteries (e.g., 2x AA 1.5V) according to the polarity markings inside the compartment.
- Sæt batteridækslet på igen og fastgør det med skruen.
4.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
This device is typically powered by the circuit it is testing. No separate battery installation is required for the test light itself.
- Connect the alligator clip to a suitable ground point (e.g., vehicle chassis for automotive applications).
- Sørg for, at probespidsen er ren og fri for snavs.
5. Betjeningsvejledning
5.1 KAIWEETS HT206D Digital Clamp Måler
Turn the rotary dial to select the desired measurement function.
5.1.1 AC/DC strømmåling (Clamp)
- Turn the rotary dial to the "600A" or "60A" AC/DC current range.
- Åbn clamp jaws and enclose a single conductor. Ensure the conductor is centered within the jaws.
- Aflæs den aktuelle værdi på displayet.
- Vigtig: To measure current, the clamp must enclose only one conductor. Clamping around an entire power cord (which contains both live and neutral wires) will result in a zero reading.

Image 5.1.1: KAIWEETS HT206D Digital Clamp Meter measuring current.
This image shows the KAIWEETS HT206D Digital Clamp Meter in use, clamping around a single electrical wire to measure current. The display shows a reading of "270.1 AC".
5.1.2 AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, Continuity, Temperature Measurement
- Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack.
- Turn the rotary dial to the desired function (e.g., V~ for AC Voltage, V- for DC Voltage, Ω for Resistance, etc.).
- For temperature measurement, connect the K-type thermocouple to the appropriate input jacks (usually marked with temperature symbols) and select the temperature function.
- Apply the test leads or thermocouple to the circuit or component under test.
- Aflæs målingen på displayet.

Image 5.1.2: KAIWEETS HT206D Digital Clamp Meter performing temperature measurement.
This image illustrates the KAIWEETS HT206D Digital Clamp Meter measuring temperature using the included K-type thermocouple. Examples show measurements in liquid, gas, and solid states, with a temperature range of -4°F to 1832°F.
5.1.3 NCV (kontaktfri volumen)tage) Registrering
- Press the NCV button (located on the right side of the meter).
- Flyt toppen af clamp meter near a live conductor.
- Måleren vil indikere tilstedeværelsen af AC-volumentage through an audible beep and/or visual indicator.

Image 5.1.3: KAIWEETS HT206D Digital Clamp Meter NCV and HOLD functions.
This image demonstrates two functions of the clamp meter. On the left, the NCV (Non-Contact Voltage) function is shown detecting voltage near an outlet. On the right, the HOLD function is activated by a short press of the 'H' button, freezing the display reading.
5.1.4 LowZ & LPF Functions
- LowZ (Low Input Impedance): Helps prevent false readings caused by "ghost voltages" in circuits. Select this mode when ghost voltages are suspected.
- LPF (lavpasfilter): Used for accurate measurement of variable frequency drive (VFD) signals, common in motor and transformer applications.
5.1.5 Data Hold (MAX/MIN)
- Press the "HOLD" button to freeze the current display reading. Press again to release.
- Press the "MAX/MIN" button to record the maximum or minimum values during a measurement session.
5.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
5.2.1 Smart Mode Operation
The test light defaults to Smart Mode, automatically detecting and measuring DC voltage, continuity, and resistance without manual range selection.
- Ensure the alligator clip is securely connected to a ground point.
- Touch the probe tip to the circuit or component to be tested.
- The display will automatically show the detected measurement type (DC Voltage, Continuity, or Resistance) and its value.

Image 5.2.1: KAIWEETS 0.8V-100V DC Smart Automotive Test Light in Smart Mode.
This image highlights the "Smart Mode" feature of the automotive test light, which automatically recognizes and measures DC Voltage, Resistance, and Continuity. The test light is shown in an automotive fuse box, demonstrating its application.
5.2.2 Wide Testing Range (0.8V-100V DC)
The test light can accurately measure DC voltages from 0.8V to 100V. If the voltage exceeds 100V, the display will show "OL" (Overload) as a warning.

Image 5.2.2: KAIWEETS 0.8V-100V DC Smart Automotive Test Light wide testing range.
This image demonstrates the test light's 0.8V-100V wide testing range, showing it connected to a car battery terminal. The display shows a voltage reading, and an inset illustrates the "OL" (Over-range warning) display for values exceeding 100V.
5.2.3 Lommelygte og baggrundsbelysning
- Press the flashlight button to activate the built-in flashlight for illuminating the work area.
- The green backlight display enhances readability in low-light conditions.

Image 5.2.3: KAIWEETS 0.8V-100V DC Smart Automotive Test Light with flashlight and backlight.
This image shows the automotive test light being used in a dark environment, highlighting its green backlight display and bright flashlight feature, which aids visibility during operation.
5.2.4 Buzzer Alarm for Continuity
When testing for continuity (typically less than 50Ω), the test light will emit an audible buzzer alarm to indicate a continuous circuit.

Image 5.2.4: KAIWEETS 0.8V-100V DC Smart Automotive Test Light buzzer alarm.
This image illustrates the buzzer alarm feature of the test light, which activates when testing for continuity (less than 50Ω). The test light is shown connected to a circuit, with visual cues indicating the sound waves from the buzzer.
6. Vedligeholdelse
- Rensning: Tør instrumentet af med adamp klud og mildt rengøringsmiddel. Brug ikke slibemidler eller opløsningsmidler.
- Battery Replacement (HT206D Clamp Meter): Når indikatoren for lavt batteri vises på displayet, skal batterierne udskiftes som beskrevet i afsnit 4.1.
- Opbevaring: Store the instruments in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove batteries from the clamp måler.
- Inspektion af sonde og ledning: Regularly inspect test leads and probes for any signs of damage, such as cuts, cracks, or exposed wiring. Replace damaged components immediately.
7. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Clamp Måleren tænder ikke. | Døde eller forkert installerede batterier. | Kontroller batteripolariteten; udskift batterierne. |
| Clamp Meter shows "OL" (Overload). | Measurement exceeds selected range or instrument's maximum capacity. | Select a higher range if available, or ensure the measurement is within the instrument's specifications. |
| Clamp Meter current reading is zero. | Clampomkring flere ledere (f.eks. en netledning). | Sørg for at clamp jaws enclose only a single conductor. |
| Test Light shows "OL". | DC voltage overstiger 100V. | Voltage is outside the test light's measurement range. Use a different instrument for higher voltages. |
| Upræcise aflæsninger. | Poor contact, damaged leads, or incorrect function selection. | Ensure good contact, inspect and replace leads if damaged, verify correct function is selected. |
8. Specifikationer
8.1 KAIWEETS HT206D Digital Clamp Måler
- Målefunktioner: AC/DC-strøm, AC/DC-volumentage, Resistance, Capacitance, Frequency/Duty Cycle, Diode, Continuity, Temperature
- Særlige funktioner: True-RMS, LowZ, LPF, NCV Detection, Data Hold (MAX/MIN)
- Sikkerhedsvurdering: CAT III 600V (refer to device for exact rating)
- Strømkilde: Battery Powered (e.g., 2x AA 1.5V)
8.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
- Målefunktioner: DC bindtage, Continuity, Resistance (Smart Mode auto-detection)
- Testområde: 0.8V - 100V DC
- Særlige funktioner: Smart Mode, Flashlight, Green Backlight Display, Buzzer Alarm
- Min. Driftsvoltage: 0.8 volt (DC)
- Sikkerhedsvurdering: 300V CAT III (refer to device for exact rating)
9. Garanti og support
KAIWEETS-produkter er designet til pålidelighed og ydeevne. For garantioplysninger, teknisk support eller serviceforespørgsler henvises til den officielle KAIWEETS-side. webwebstedet eller kontakt deres kundeservice direkte. Behold din købskvittering som købsbevis.