DewertOKIN ZYT-36S-42

DewertOKIN ZYT-36S-42 Massage Motor Replacement Manual

Model: ZYT-36S-42 | Brand: DewertOKIN

Indledning

This manual provides essential information for the installation, operation, and maintenance of the DewertOKIN ZYT-36S-42 massage motor. This motor is designed as a direct replacement for existing OKIN massage motors in adjustable bed bases, specifically for head or feet massage functions. It is crucial to verify compatibility, particularly the connector type, before installation.

Vigtige sikkerhedsoplysninger

Produkt overview

The ZYT-36S-42 is a compact DC massage motor designed for adjustable bed bases. It features a durable black casing, an integrated power cable, and a specific connector for easy integration into compatible systems. This motor is interchangeable and can be used to replace either the head or feet massage motor in your adjustable bed.

DewertOKIN ZYT-36S-42 massage motor with cable and connector

Figur 1: The DewertOKIN ZYT-36S-42 massage motor, showing its cylindrical body, attached power cable, and white two-pin connector. This is the complete unit as it appears out of the packaging.

Side view of DewertOKIN ZYT-36S-42 massage motor with specification label

Figur 2: En side view of the ZYT-36S-42 massage motor, highlighting the product label. The label displays key specifications such as "DC MOTOR", "ZYT-36S-42", "24V", and "2500RPM ±10%".

Close-up of the two-pin connector on the ZYT-36S-42 massage motor cable

Figur 3: A detailed close-up of the white two-pin connector attached to the motor's power cable. This connector type is critical for ensuring compatibility with your adjustable bed base's wiring harness.

Installationsvejledning

Follow these steps carefully to replace your adjustable bed's massage motor. Ensure you have the correct replacement motor by checking the connector type before proceeding.

  1. Forbered sengen: Unplug the adjustable bed base from the wall outlet to completely cut off power.
  2. Locate Existing Motor: Identify the massage motor you intend to replace. This will typically be located near the head or foot section of the bed frame, often secured with screws or clips.
  3. Afbryd den gamle motor: Carefully disconnect the power cable of the old motor from the bed's wiring harness. Note how it is connected.
  4. Fjern den gamle motor: Unscrew or unclip the old motor from its mounting bracket on the bed frame.
  5. Installer ny motor: Position the new DewertOKIN ZYT-36S-42 motor into the mounting bracket. Secure it firmly using the original screws or clips.
  6. Connect New Motor: Connect the new motor's two-pin connector to the corresponding port on the bed's wiring harness. Ensure a snug and secure fit.
  7. Test funktionalitet: Once the motor is securely installed and connected, plug the adjustable bed base back into the power outlet. Test the massage function to ensure the new motor operates correctly.
  8. Kabelstyring: Route the motor's cable neatly and secure it to prevent it from being pinched or tangled during bed operation.

Note: This motor is interchangeable and can be used for either the head or feet massage function.

Betjeningsvejledning

The DewertOKIN ZYT-36S-42 massage motor operates as an integral component of your adjustable bed base. It does not have independent controls. Its function is controlled directly by the bed's remote control or integrated control panel.

Opretholdelse

The ZYT-36S-42 massage motor is designed for minimal maintenance. Regular inspection can help ensure its longevity and proper function.

Fejlfinding

If you experience issues with your DewertOKIN ZYT-36S-42 massage motor, consult the table below for common problems and their potential solutions.

ProblemMulig årsagLøsning
Motor does not vibrate or is unresponsive.
  • Bed not plugged in.
  • Loose or disconnected motor cable.
  • Faulty bed remote or control unit.
  • Defekt motor.
  • Ensure the bed base is securely plugged into a working power outlet.
  • Check that the motor's connector is firmly seated in the bed's wiring harness.
  • Test other functions of the bed. If other functions also fail, the issue may be with the bed's power supply or control unit.
  • If all connections are secure and the bed's control unit is functional, the motor may be faulty and require replacement.
Weak or inconsistent vibration.
  • Partial connection of motor cable.
  • Obstruction around the motor.
  • Motor nearing end of life.
  • Unplug the bed, then firmly re-seat the motor's connector.
  • Check for any objects (bedding, wires) that might be dampening the vibration.
  • If the motor is old, its performance may degrade over time.
Unusual noises from the motor.
  • Løs montering.
  • Internt motorproblem.
  • Ensure the motor is securely fastened to its mounting bracket.
  • If the noise persists and the motor is new, it may indicate a manufacturing defect. If old, it may be failing.

Hvis fejlfindingstrinene ikke løser problemet, bedes du kontakte kundesupport.

Tekniske specifikationer

SpecifikationDetalje
ModelnummerZYT-36S-42
TypeDC Massage Motor
Voltage24V
Nominel RPM2500 RPM ±10 %
KompatibilitetReplaces OKIN branded massage motors only. Interchangeable for head or feet massage.
Connector TypeTwo-pin (as shown in Figure 3)

Garantioplysninger

Specific warranty terms for the DewertOKIN ZYT-36S-42 massage motor are typically provided by the seller at the time of purchase. Please refer to your original purchase documentation or contact the seller directly for detailed warranty coverage, duration, and claim procedures.

For purchases made from "Irvine Home Collection USA", please consult their specific return and warranty policies.

Kundesupport

If you have questions or require further assistance with your DewertOKIN ZYT-36S-42 massage motor, please contact the seller from whom you purchased the product. When contacting support, please have your purchase details and the product's ASIN (B0DNRSX673) readily available for faster service.

For general inquiries about DewertOKIN products, you may also visit the official DewertOKIN webwebsted.

Relaterede dokumenter - ZYT-36S-42

Preview DewertOkin OKIMAT 4 Series Installation Manual
Installation manual for DewertOkin OKIMAT 4 series electric bed actuators (IPS, IPSe, EPS, EPSe), detailing mounting, safety, technical specifications, and troubleshooting for adjustable bed systems.
Preview Brugermanual til RF48 fjernbetjening - DewertOkin
Brugermanual til DewertOkin RF48 fjernbetjeningen, med detaljerede oplysninger om dens funktioner, tilstande og betjening af justerbare senge, inklusive massage og kontroller til specialpositioner.
Preview DewertOkin Motion Assist / Motion Assist Pro Control-tastatur brugermanual
Denne manual indeholder en funktionsbeskrivelse, installationsvejledning, betjeningsvejledning, fejlfindingstips og vedligeholdelsesoplysninger til DewertOkin Motion Assist og Motion Assist Pro kontrolpaneler, der bruges med OKIN-drevsystemer til højdejusterbare borde.
Preview OKIMAT 4 Installation Instructions: IPS, IPSe, EPS, EPSe Actuator Systems
Detailed installation instructions for DewertOkin's OKIMAT 4 series electric actuators (IPS, IPSe, EPS, EPSe), designed for adjustable bed mechanisms. Learn about proper setup, safety, and technical specifications.
Preview OKIMAT 4 Installation Instructions for IPS, IPSe, EPS, EPSe Drives
Detailed installation instructions for DewertOkin's OKIMAT 4 series drives (IPS, IPSe, EPS, EPSe). Covers safety guidelines, component descriptions, technical specifications, installation procedures, and troubleshooting for integrating these electric drives into end products like beds.
Preview DUOMAT 9 Installation Instructions - DewertOkin
Comprehensive installation guide for the DewertOkin DUOMAT 9 electric drive system, detailing setup, safety protocols, technical specifications, and troubleshooting for manufacturers of adjustable furniture and medical equipment.