Indledning
This manual provides essential information for the installation, operation, and maintenance of the DewertOKIN ZYT-36S-42 massage motor. This motor is designed as a direct replacement for existing OKIN massage motors in adjustable bed bases, specifically for head or feet massage functions. It is crucial to verify compatibility, particularly the connector type, before installation.
Vigtige sikkerhedsoplysninger
- Afbryd strømmen: Always ensure the adjustable bed base is unplugged from the power outlet before attempting any installation, removal, or maintenance of the massage motor.
- Professionel installation: If you are unsure about any step of the installation process, it is recommended to seek assistance from a qualified technician.
- Efterse komponenter: Before installation, carefully inspect the new motor and its cable for any signs of damage. Do not install damaged components.
- Hold tør: This motor is not designed for use in wet or damp environments. Keep it away from liquids.
- Korrekt forbindelse: Ensure all electrical connections are secure and correctly matched to prevent electrical hazards or malfunction.
Produkt overview
The ZYT-36S-42 is a compact DC massage motor designed for adjustable bed bases. It features a durable black casing, an integrated power cable, and a specific connector for easy integration into compatible systems. This motor is interchangeable and can be used to replace either the head or feet massage motor in your adjustable bed.

Figur 1: The DewertOKIN ZYT-36S-42 massage motor, showing its cylindrical body, attached power cable, and white two-pin connector. This is the complete unit as it appears out of the packaging.

Figur 2: En side view of the ZYT-36S-42 massage motor, highlighting the product label. The label displays key specifications such as "DC MOTOR", "ZYT-36S-42", "24V", and "2500RPM ±10%".

Figur 3: A detailed close-up of the white two-pin connector attached to the motor's power cable. This connector type is critical for ensuring compatibility with your adjustable bed base's wiring harness.
Installationsvejledning
Follow these steps carefully to replace your adjustable bed's massage motor. Ensure you have the correct replacement motor by checking the connector type before proceeding.
- Forbered sengen: Unplug the adjustable bed base from the wall outlet to completely cut off power.
- Locate Existing Motor: Identify the massage motor you intend to replace. This will typically be located near the head or foot section of the bed frame, often secured with screws or clips.
- Afbryd den gamle motor: Carefully disconnect the power cable of the old motor from the bed's wiring harness. Note how it is connected.
- Fjern den gamle motor: Unscrew or unclip the old motor from its mounting bracket on the bed frame.
- Installer ny motor: Position the new DewertOKIN ZYT-36S-42 motor into the mounting bracket. Secure it firmly using the original screws or clips.
- Connect New Motor: Connect the new motor's two-pin connector to the corresponding port on the bed's wiring harness. Ensure a snug and secure fit.
- Test funktionalitet: Once the motor is securely installed and connected, plug the adjustable bed base back into the power outlet. Test the massage function to ensure the new motor operates correctly.
- Kabelstyring: Route the motor's cable neatly and secure it to prevent it from being pinched or tangled during bed operation.
Note: This motor is interchangeable and can be used for either the head or feet massage function.
Betjeningsvejledning
The DewertOKIN ZYT-36S-42 massage motor operates as an integral component of your adjustable bed base. It does not have independent controls. Its function is controlled directly by the bed's remote control or integrated control panel.
- Aktivering: To activate the massage function, use the designated buttons on your adjustable bed's remote control. Refer to your bed base's user manual for specific instructions on operating its massage features.
- Vibrationsintensitet: The intensity of the massage vibration is typically controlled by the bed's remote. The ZYT-36S-42 motor provides a consistent vibration output as per its design specifications.
- Deaktivering: Turn off the massage function using your bed's remote control.
Opretholdelse
The ZYT-36S-42 massage motor is designed for minimal maintenance. Regular inspection can help ensure its longevity and proper function.
- Rensning: Periodically, with the bed unplugged, gently wipe the motor and its cable with a dry, soft cloth to remove dust and debris. Do not use liquid cleaners or abrasive materials.
- Kabelinspektion: Regularly check the motor's power cable for any signs of fraying, cuts, or damage. Ensure the connector remains securely attached.
- Monteringssikkerhed: Verify that the motor remains securely mounted to the bed frame. Tighten any loose screws if necessary, ensuring not to overtighten.
- Undgå forhindringer: Ensure no bedding, clothing, or other objects are obstructing the motor or its cable, which could lead to overheating or damage.
Fejlfinding
If you experience issues with your DewertOKIN ZYT-36S-42 massage motor, consult the table below for common problems and their potential solutions.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Motor does not vibrate or is unresponsive. |
|
|
| Weak or inconsistent vibration. |
|
|
| Unusual noises from the motor. |
|
|
Hvis fejlfindingstrinene ikke løser problemet, bedes du kontakte kundesupport.
Tekniske specifikationer
| Specifikation | Detalje |
|---|---|
| Modelnummer | ZYT-36S-42 |
| Type | DC Massage Motor |
| Voltage | 24V |
| Nominel RPM | 2500 RPM ±10 % |
| Kompatibilitet | Replaces OKIN branded massage motors only. Interchangeable for head or feet massage. |
| Connector Type | Two-pin (as shown in Figure 3) |
Garantioplysninger
Specific warranty terms for the DewertOKIN ZYT-36S-42 massage motor are typically provided by the seller at the time of purchase. Please refer to your original purchase documentation or contact the seller directly for detailed warranty coverage, duration, and claim procedures.
For purchases made from "Irvine Home Collection USA", please consult their specific return and warranty policies.
Kundesupport
If you have questions or require further assistance with your DewertOKIN ZYT-36S-42 massage motor, please contact the seller from whom you purchased the product. When contacting support, please have your purchase details and the product's ASIN (B0DNRSX673) readily available for faster service.
For general inquiries about DewertOKIN products, you may also visit the official DewertOKIN webwebsted.