MAXSafes 10002V

MAXSafes Model 10002V Biometrisk Sikkerhedsskab til Håndvåben Brugsanvisning

Model: 10002V | Brand: MAXSafes

1. Introduktion

Thank you for choosing the MAXSafes Model 10002V Drop Down Biometric Handgun Safe. This safe is designed to provide secure storage and quick access to your firearm using advanced finger vein recognition, a digital keypad, or a mechanical key. Please read this manual thoroughly before installation and operation to ensure proper use and maximum security.

MAXSafes 10002V Drop Down Biometric Handgun Safe with a handgun inside, open and ready for quick access.

Figure 1: MAXSafes Model 10002V Drop Down Biometric Handgun Safe

2. Sikkerhedsoplysninger

ADVARSEL: Always store firearms unloaded and separate from ammunition. Keep the safe locked and out of reach of children and unauthorized individuals. Never store the mechanical override keys inside the safe. Familiarize yourself with all local and federal laws regarding firearm storage.

3. Pakkens indhold

Bekræft at alle varer er til stede i pakken:

4. Produktet er slutview

The MAXSafes 10002V features a robust design with multiple access options for enhanced security and convenience.

Diagram showing the MAXSafes 10002V safe with features highlighted: Vein Recognition, Digital Keypad, Backup Mechanical Key, Drop and Pry Resistant, Flip Down Design, 16 Gauge Carbon Steel, and CA DOJ Approved seal.

Figure 2: Key Features of the MAXSafes 10002V

Komponenter:

Nærbillede view of the MAXSafes 10002V safe's control panel, showing the finger vein scanner, digital keypad, and mechanical keyhole.

Figure 3: Access Methods - Vein Recognition, Digital Keypad, Mechanical Key

5. Opsætning

5.1 Batteriinstallation

  1. Locate the battery compartment, typically on the underside or rear of the safe.
  2. Åbn dækslet til rummet.
  3. Isæt 4 AA-batterier (medfølger ikke), og sørg for korrekt polaritet (+/-).
  4. Luk batterirummets dæksel forsvarligt.
  5. The safe will emit a beep, indicating successful power-up.

5.2 Initial Access and Programming

Upon first use, access the safe using the mechanical override key.

  1. Insert the mechanical key into the keyhole and turn it to unlock the safe.
  2. Åbn pengeskabsdøren.

5.2.1 Setting a Digital Combination Code

  1. With the safe door open, locate the internal programming button (usually a small red or green button).
  2. Press the programming button. The indicator light on the keypad will illuminate.
  3. Indtast din ønskede 4-6-cifrede kode på tastaturet.
  4. Press the programming button again to confirm. The safe will beep to confirm the new code.
  5. Test den nye kode med døren åben, før du lukker den.

5.2.2 Registering Finger Vein IDs

The safe can store up to 50 finger vein IDs.

  1. With the safe door open, press the programming button. The indicator light will illuminate.
  2. Place your finger firmly on the vein scanner. The scanner will light up and beep.
  3. Lift and reposition your finger slightly, then place it on the scanner again. Repeat this process 3-5 times from different angles to ensure a comprehensive scan.
  4. A successful registration will be indicated by a series of beeps.
  5. Repeat for additional fingers or users (up to 50).
  6. Test registered finger veins with the door open before closing it.
Diagram illustrating the advanced finger vein recognition technology, showing how veins are scanned and recognized, emphasizing its resistance to moisture, stains, and dirt.

Figure 4: Finger Vein Recognition Technology

5.3 Montering af pengeskabet

The safe can be mounted to a wall or desk. Choose a secure location that is out of sight and reach of unauthorized persons.

  1. Select a suitable mounting location (e.g., under a desk, inside a cabinet, on a wall stud).
  2. Position the safe in the desired location and mark the mounting points through the pre-drilled holes on the safe's back or bottom.
  3. Drill pilot holes into the mounting surface using an appropriate drill bit size for the provided hardware.
  4. Align the safe with the drilled holes and secure it using the provided screws and anchors. Ensure the safe is firmly attached and does not wobble.
Four images showing the MAXSafes 10002V safe mounted in various locations: inside a closet, under a desk, inside a kitchen island cabinet, and next to a bed.

Figur 5: Eksamples of Wall and Desk Mounting Options

6. Betjeningsvejledning

6.1 Opening with Finger Vein Recognition

  1. Place a registered finger firmly on the vein scanner.
  2. The scanner will light up, and the safe will emit a confirmation beep if the vein pattern is recognized.
  3. The safe door will automatically drop down, providing quick access.

6.2 Opening with Digital Keypad

  1. Enter your programmed 4-6 digit combination code on the keypad.
  2. The safe will emit a confirmation beep if the code is correct.
  3. The safe door will automatically drop down.

6.3 Opening with Mechanical Key

Use the mechanical key as a backup in case of battery failure or forgotten codes.

  1. Locate the keyhole cover (if present) and remove it.
  2. Insert the mechanical key into the keyhole and turn it to unlock the safe.
  3. The safe door will open.

6.4 Lydløs tilstand

The safe features a silent mode for discreet access. Refer to the safe's specific button layout for activating/deactivating silent mode (often a dedicated button or a combination press).

6.5 Alarmtilstand

The safe is equipped with an audible alarm. This alarm may activate if multiple incorrect access attempts are made or if the safe is tampered with. Consult the safe's interface for specific alarm settings or deactivation procedures.

6.6 Indvendig LED-lys

The interior LED light automatically illuminates when the safe door opens, providing visibility in low-light conditions.

7. Vedligeholdelse

7.1 Udskiftning af batteri

When the low battery indicator (usually a flashing light or specific beep pattern) appears, replace all 4 AA batteries promptly. Use high-quality alkaline batteries for optimal performance.

7.2 Rengøring

Tør ydersiden af ​​pengeskabet af med en blød, tør klud.amp cloth. Avoid using abrasive cleaners or solvents that could damage the finish or electronic components. Keep the finger vein scanner clean and free of debris.

7.3 Regular Function Check

Periodically test all access methods (finger vein, keypad, mechanical key) to ensure they are functioning correctly. This helps identify potential issues before they become critical.

8. Fejlfinding

If you encounter issues with your MAXSafes 10002V, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
Finger vein not recognizedImproper finger placement, unregistered finger, dirty scanner, skin conditions (e.g., very dry, damaged).Ensure firm and consistent finger placement. Re-register the finger, trying different angles. Clean the scanner. Try another registered finger or access method.
Tastaturet reagerer ikkeLow batteries, incorrect code, keypad malfunction.Replace batteries. Re-enter code carefully. Use mechanical key if necessary.
Sikker ikke åbningLow batteries, incorrect access, mechanical obstruction.Replace batteries. Try all access methods. Check for any obstructions preventing the door from dropping.
Indikator for lavt batteriBatterierne er lave.Udskift alle 4 AA-batterier med det samme.

9. Specifikationer

Detailed specifications for the MAXSafes Model 10002V:

Image showing the dimensions of the MAXSafes 10002V safe: 13.8 inches high, 11.13 inches deep, 3.77 inches wide, and 16.2 inches high when open. Also shows two mechanical keys.

Figure 6: Product Dimensions and Included Keys

10. Garanti og support

MAXSafes products are manufactured to high-quality standards. For warranty information or technical support, please refer to the contact details provided with your purchase documentation or visit the official MAXSafes webwebsted. Gem din købskvittering som købsbevis i tilfælde af garantikrav.

Relaterede dokumenter - 10002V

Preview MAXSafes affugterstang - Funktioner, betjening og installationsvejledning
Lær om MAXSafes affugterstang (varenummer 40001), inklusive dens funktioner, betjening, korrekte plejeinstruktioner og montering/fjernelse af stik for sikker fugtighedskontrol.
Preview MAXSafes KD Cabinet User Manual - Assembly and Operation Guide
Comprehensive user manual for MAXSafes KD Cabinets (models 60005KL and 60005DK), covering assembly, installation, operation, and programming. Includes parts list and safety instructions.
Preview MAXSafes 20002 SR Digital Lock Box RFID User Manual
Comprehensive user manual for the MAXSafes 20002 SR Digital Lock Box with RFID and keypad access. Includes setup, battery, programming codes and RFIDs, operation, security features, troubleshooting, and key replacement instructions.
Preview MAXSafes affugterstang - Varenummer 40001
Instruktioner og funktioner til MAXSafes affugterstang, designet til at kontrollere fugt i pengeskabe og kabinetter for at forhindre rust og beskytte værdigenstande.
Preview MAXSafes 40003 Genopladelig Affugter og LED-bevægelseslys Brugermanual
Brugermanual til MAXSafes 40003 genopladelig affugter med LED-bevægelseslys. Indeholder funktioner, sikkerhedsinstruktioner, betjening, tørring, specifikationer og kontaktoplysninger.
Preview MAXSafes begrænset livstidsgaranti - Produktbeskyttelse
Forstå MAXSafes' begrænsede livstidsgaranti for sikkerhedsprodukter. Dette dokument beskriver dækning, undtagelser og processen for at fremsætte et garantikrav, så din investering er beskyttet.