1. Produktet er slutview
The FOTING In/Above Ground Pool Pump is a self-priming, dual-speed pump designed for efficient water circulation in various swimming pools. Equipped with a robust 2HP copper wire motor, it offers a flow rate of up to 3170 GPH (low speed) and 7000 GPH (high speed), with a maximum head lift of 69 feet. This pump features thermal overload protection for enhanced safety and longevity, and includes a removable filter basket and drain plug for easy maintenance. It is suitable for both above-ground and in-ground pool applications, as well as water parks, bathing pools, hot tubs, spas, and irrigation systems.

Figure 1: FOTING In/Above Ground Pool Pump with included 1.5" and 2" NPT inlet connectors and waterproof tape.
2. Sikkerhedsoplysninger
Læs og forstå alle sikkerhedsinstruktioner før installation og betjening. Manglende overholdelse af disse instruktioner kan resultere i elektrisk stød, brand eller alvorlig personskade.
- Afbryd altid strømmen til pumpen, før du udfører service eller vedligeholdelse.
- Ensure the electrical supply matches the pump's voltage krav (230V).
- The pump must be installed by a qualified electrician in accordance with all local and national electrical codes.
- Do not operate the pump if the power cord is damaged.
- Keep children and unauthorized persons away from the pump during operation.
- The pump is equipped with thermal overload protection. If the pump stops unexpectedly, allow it to cool down before attempting to restart. Investigate potential causes such as clogs or insufficient water flow.
3. Opsætning og installation
Proper installation is crucial for the pump's performance and longevity. The pump is self-priming, but proper plumbing connections are essential.
3.1 Udpakning og inspektion
- Fjern forsigtigt alle komponenter fra emballagen.
- Verify that all parts are present: pump unit, two 1.5" NPT inlet adapters, two 2" NPT inlet adapters, and waterproof tape.
- Inspect the pump for any visible damage that may have occurred during shipping. Do not install if damaged.
3.2 Placering
- Place the pump on a solid, level surface near the pool.
- Sørg for tilstrækkelig ventilation omkring motoren.
- Position the pump to minimize the length of suction and discharge piping.
3.3 VVS-tilslutninger
The FOTING pump supports two methods for water pipe connection using the included 1.5" and 2" NPT inlet adapters.

Figure 2: Two methods for connecting water pipes to the pump, utilizing 1.5-inch and 2-inch PVC pipe adapters.
- Method 1: Direct PVC Pipe Connection
Connect 1.5" or 2" PVC pipes directly to the pump's inlet and outlet ports using the appropriate adapters and waterproof tape for a secure, leak-free seal. - Method 2: Flexible Hose Connection
Utilize the provided adapters to connect flexible hoses (1.5" or 2") to the pump. Ensure hose clamps are used for a tight connection. - Ensure all connections are sealed properly to prevent air leaks, which can affect pump priming and efficiency.
3.4 Elektrisk tilslutning
This pump operates on 230V. A power cord is not included and must be wired by a qualified electrician according to local electrical codes.
- Ensure the power supply is off before making any electrical connections.
- Connect the pump to a dedicated circuit with appropriate overcurrent protection.
- Bekræft korrekt voltage og ampslette bedømmelser.
4. Betjening
The FOTING pool pump features dual-speed operation, allowing you to optimize performance and energy consumption.
4.1 Spædning af pumpen
- Before initial startup, ensure the pump is filled with water through the skimmer or by removing the transparent lid and filling the filter basket housing.
- Close all drain valves and ensure the pool water level is above the skimmer.
- Once filled, replace the lid securely. The pump's self-priming capability will then quickly establish water flow.
4.2 Dual Speed Control
The pump offers two operating speeds: High and Low. A switch located at the bottom of the motor allows you to select the desired speed.

Figure 3: High Speed mode provides 7000 GPH for rapid water circulation and daytime use.
- High Speed (7000 GPH): Ideal for faster filtration, cycling the entire pool volume quickly, and during periods of heavy use or when cleaning the pool.

Figure 4: Low Speed mode provides 3170 GPH for energy saving and quieter operation during off-peak hours.
- Low Speed (3170 GPH): Recommended for energy saving, quieter operation, and maintaining filtration during less active periods or overnight.
Adjust the speed based on your pool's size, filtration requirements, and desired energy consumption.
5. Vedligeholdelse
Regular maintenance ensures optimal performance and extends the lifespan of your FOTING pool pump.
5.1 Rengøring af filterkurven
The pump is equipped with a removable filter basket to capture debris. The transparent lid allows for easy visual inspection.

Figure 5: The extra-large filter basket effectively collects leaves, twigs, and gravel, and is easily removable for cleaning.
- Sluk pumpen og afbryd strømmen.
- Unscrew the transparent lid counter-clockwise.
- Fjern filterkurven, og tøm eventuelt opsamlet snavs.
- Skyl kurven grundigt med vand.
- Undersøg O-ringen på låget for revner eller slid; udskift om nødvendigt.
- Place the clean basket back into the pump and securely fasten the lid.
5.2 Draining the Pump
The integrated drain plug allows for easy water drainage, particularly useful for winterization or extended periods of non-use.

Figur 6: Overview of pump features including the drain plug for easy water removal and the transparent cover for filter basket visibility.
- Sluk pumpen og afbryd strømmen.
- Locate the drain plug at the bottom of the pump housing.
- Unscrew the drain plug to allow water to exit the pump.
- Once drained, replace the plug securely.
6. Fejlfinding
This section provides solutions to common issues you may encounter with your FOTING pool pump.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Pumpen starter ikke | Ingen strømforsyning Termisk overbelastning aktiveret Motor problem | Kontroller strømtilslutning og afbryder. Allow pump to cool down; check for clogs. Kontakt kundesupport, hvis problemet fortsætter. |
| Pump runs but no water flow | Pumpen ikke primet Luftlækage i sugeledningen Clogged filter basket/impeller | Sørg for, at pumpen er fyldt med vand. Check all suction line connections for tightness. Clean filter basket; inspect impeller for debris. |
| Reduceret vandgennemstrømning | Tilstoppet filterkurv Partially blocked plumbing Low pool water level | Rengør filterkurven. Inspect and clear plumbing lines. Ensure pool water level is adequate. |
| Overdreven støj | Luftlækage Affald i pumpehjulet Motor bearing wear | Check suction line for air leaks. Rengør pumpehjulet. Kontakt kundesupport. |
7. Specifikationer
Detailed technical specifications for the FOTING In/Above Ground Pool Pump.
| Attribut | Værdi |
|---|---|
| Mærke | FOTING |
| Modelnummer | J11502-Dual Speed-230V |
| Stil | 2HP Dual Speed-230V |
| Farve | Black&blue |
| Materiale | Termoplastisk |
| Produktmål (L x B x H) | 25.5 cm x 7.8 cm x 11 cm |
| Varens vægt | 37 pund |
| Strømkilde | AC |
| Voltage | 230 volt |
| Maksimal flowhastighed | 116 gallon pr. minut (7000 GPH) |
| Maksimal løftehøjde | 69 fod |
| Motortype | Copper Wire Motor |
| Beskyttelse | Termisk overbelastningsbeskyttelse |

Figure 7: Performance curve illustrating the relationship between head lift and flow rate for both high and low speeds.
8. Garanti og support
FOTING provides a THREE-YEAR after-sale service for this product.
If you encounter any problems or have questions regarding your FOTING pool pump, please contact our customer support team for assistance. Refer to your purchase documentation for specific contact details or visit the official FOTING webwebsted.