This manual provides essential information for the safe and efficient operation of your FOTING 2.5HP Dual Voltage In/Above Ground Pool Pump. This pump is equipped with a robust copper wire motor, delivering exceptional efficiency and performance for pool maintenance. Its self-priming capability ensures a quick start and consistent water flow. Please read all instructions carefully before installation and use.

FOTING 2.5HP Dual Voltage Pool Pump
Figure 1: FOTING 2.5HP Dual Voltage Pool Pump. This image shows the main unit of the FOTING pool pump, featuring its black housing, blue motor, and white pipe connectors, ready for installation.

2. Sikkerhedsoplysninger

ADVARSEL: To reduce the risk of electric shock, fire, or injury, always follow these safety precautions:

  • Always turn off and disconnect power to the pump before performing any electrical connections, maintenance, or service.
  • Ensure the pump is installed by a qualified electrician in accordance with all local and national electrical codes.
  • Brug ikke pumpen, hvis netledningen eller stikket er beskadiget.
  • Keep children and unauthorized persons away from the pump during operation.
  • The pump is equipped with thermal overload protection to prevent motor burnout. This feature is crucial for maintaining system integrity during prolonged use.
  • Do not run the pump dry. Ensure the pump is properly primed with water before starting to prevent damage.

3. Pakkens indhold

Bekræft at alle varer er til stede i pakken:

  • FOTING 2.5HP Dual Voltage Pool Pump Unit
  • Two (2) 1.5-inch Inlet Adapters
  • Two (2) 2-inch Inlet Adapters
  • Vandtæt tape
  • Instruktionsmanual (dette dokument)

4. Opsætning og installation

4.1. Valg af sted

  • Place the pump on a solid, level surface.
  • Ensure adequate ventilation around the pump.
  • Position the pump as close to the pool as possible to minimize friction loss in plumbing.
  • Protect the pump from direct sunlight and harsh weather conditions.

4.2. Electrical Connection (Dual Voltage)

This pump supports both 115V and 230V operation. The voltage setting must be configured correctly before use. Refer to the wiring diagram inside the motor's bottom cover for specific connections.

  • VIGTIG: Ensure the power supply is OFF before proceeding.
  • Open the bottom cover of the motor to access the wiring terminals.
  • Connect the power supply wires according to the diagram for either 115V or 230V, matching your electrical system.
  • Secure all connections tightly and replace the motor cover.
Person connecting FOTING pool pump
Figure 2: Electrical Connection. This image illustrates a person wearing gloves making connections to the FOTING pool pump, highlighting the dual voltage capability and the importance of careful wiring.
Dual Voltage options for FOTING pool pump
Figure 3: Dual Voltage Selection. This image visually represents the choice between 220V-240V and 110V-120V operation for the FOTING pool pump, emphasizing its versatility.

4.3. Tilslutning af vandrør

The pump includes 1.5-inch and 2-inch NPT inlet adapters for flexible plumbing options. Use the provided waterproof tape for secure, leak-free connections.

  • Determine the appropriate adapter size (1.5" or 2") for your pool plumbing.
  • Apply waterproof tape to the threaded connections of the pump and adapters.
  • Securely attach the adapters to the pump's inlet and outlet ports.
  • Connect your pool's plumbing (PVC pipes or flexible hoses) to the installed adapters.
Two methods for water pipe connection
Figure 4: Water Pipe Connection Methods. This diagram illustrates two common methods for connecting water pipes to the pump, showing the use of 1.5-inch and 2-inch PVC pipe adapters and couplers.

5. Betjeningsvejledning

5.1. Priming af pumpen

Before starting the pump for the first time, or after draining for maintenance, the pump must be primed.

  1. Ensure all valves are open to allow water flow from the pool to the pump.
  2. Fjern det gennemsigtige låg på filterkurven.
  3. Fill the filter basket housing with water until it overflows.
  4. Replace and securely tighten the transparent lid.
  5. Turn on the power to the pump. The pump should begin to draw water and establish flow. If not, repeat the priming process.

5.2. Normal drift

Once primed, the pump will continuously circulate water through your pool's filtration system. Monitor the pressure gauge on your filter (if applicable) to ensure proper operation. Refer to your filter's manual for ideal operating pressure ranges.

6. Vedligeholdelse

6.1. Rengøring af filterkurven

The large removable filter basket collects debris and should be cleaned regularly to maintain pump efficiency.

  1. ADVARSEL: Turn off power to the pump before cleaning.
  2. Luk alle nødvendige ventiler for at forhindre vand i at løbe ud af poolen.
  3. Unscrew and remove the transparent lid of the filter basket. The transparent lid allows you to view the condition of the filter without removal.
  4. Lift out the filter basket.
  5. Empty any collected debris and rinse the basket thoroughly with water.
  6. Inspect the O-ring on the lid for damage and ensure it is clean and properly seated.
  7. Return the clean basket to its housing and securely replace the lid.
  8. Re-open valves and re-prime the pump if necessary.
Person removing filter basket from FOTING pool pump
Figure 5: Removing Filter Basket. This image shows hands removing the extra-large filter basket from the pump, demonstrating the ease of access for cleaning leaves, branches, and gravel.

6.2. Draining the Pump

For winterization or extended periods of non-use, the pump should be drained to prevent freezing and damage.

  1. ADVARSEL: Turn off power to the pump.
  2. Close all valves between the pool and the pump.
  3. Locate the drain plug at the bottom of the pump housing.
  4. Remove the drain plug to allow all water to exit the pump.
  5. Once drained, replace the drain plug.

7. Fejlfinding

This section addresses common issues you might encounter with your pool pump.

ProblemMulig årsagLøsning
Pumpen starter ikkeNo power; tripped breaker; faulty wiringCheck power supply, reset breaker, verify wiring connections.
Pump runs but does not prime or move waterAir leak in suction line; low water level; clogged filter basket; pump not filled with waterCheck for leaks, ensure adequate pool water level, clean filter basket, re-prime pump.
Reduceret vandgennemstrømningClogged filter basket; dirty filter; partially closed valves; air in systemClean filter basket, backwash/clean filter, ensure all valves are fully open, check for air leaks.
Pumpen larmerAir leak in suction line; cavitation; worn bearingsCheck for air leaks, ensure proper water flow to pump, contact support if bearings are suspected.
Pump leaks waterLøse forbindelser; beskadigede O-ringe/tætningerTighten connections, inspect and replace O-rings/seals as needed.

8. Specifikationer

Technical details for the FOTING 2.5HP Dual Voltage Pool Pump (Model: J15001-Dual Voltagog).

  • Mærke: FOTING
  • Modelnummer: J15001-Dual Voltage
  • Hestekræfter (HK): 2.5 HK
  • Maksimal gennemstrømningshastighed: 7000 GPH (Gallons Per Hour) / 116 GPM (Gallons Per Minute)
  • Maksimal løftehøjde: 79 fod
  • Voltage: 115V / 230V (AC)
  • Strømkilde: AC
  • Materiale: Termoplastisk
  • Farve: Sort & Blå
  • Produktdimensioner: 25.5 cm L x 7.8 cm B x 11 cm H
  • Varens vægt: 28.5 pund
  • Selvansugende: Ja
  • Termisk overbelastningsbeskyttelse: Ja
  • Inlet Connectors: 1.5" NPT & 2" NPT
Indre view of FOTING 2.5HP Copper Motor
Figure 6: 2.5HP Copper Motor. This image provides an internal view of the pump's 2.5HP copper motor, highlighting its powerful performance, self-priming capability, overheated protection, and low noise operation.

9. Garanti og support

FOTING is committed to providing reliable products and customer satisfaction. For technical assistance, warranty claims, or any questions regarding your pool pump, please contact FOTING customer service. Our team provides professional technical support to ensure your water system remains stable and worry-free.

Se venligst din købsdokumentation for specifikke garantivilkår og kontaktoplysninger.

Relaterede dokumenter - J15001-Dual Voltage

Preview XtremepowerUS 1.5 HP 230V 2-Speed Inground Pool Pump Installation and User's Guide
Comprehensive installation and user's guide for the XtremepowerUS 1.5 HP 230V 2-Speed Inground Pool Pump (SKU: 75406). Covers safety instructions, installation, operation, maintenance, troubleshooting, and specifications.
Preview XtremepowerUS 2HP Inground Pool Pump 5850GPH Dual Voltage Motor Owner's Manual and Safety Instructions
Owner's manual and safety instructions for the XtremepowerUS 2HP Inground Pool Pump (Model 75035) with 5850 GPH capacity and dual voltage motor. Includes installation, operation, maintenance, and troubleshooting guides.
Preview Stark Tool USA 75038 Poolpumpemotor Installationsvejledning og ledningsføringsinstruktioner
Detaljeret installations- og ledningsføringsvejledning til Stark Tool USA 75038 poolpumpemotor. Indeholder sikkerhedsadvarsler, trinvise instruktioner og dobbelt volumen.tage-konfigurationsdetaljer for 110/120V og 220/230V drift.
Preview VEVOR Dobbelthastigheds-poolpumpe Brugermanual
Omfattende brugermanual til VEVOR dobbelthastigheds-poolpumper (VVPS215BUS 1.5 HK 230 V, VVPS220BUS 2.0 HK 230 V), der dækker installation, sikkerhedsforanstaltninger, ledningsføring, priming, service, opbevaring og fejlfinding.
Preview Tidal Wave Maxi II Overjordisk Poolpumpe med Dobbelt Hastighed, Manuel
Instruktionsmanual til Blue Wave Tidal Wave Maxi II overjordisk dobbelthastigheds-poolpumpe, inklusive sikkerhedsoplysninger, delesammenbrud, installation, betjening, vedligeholdelse, fejlfinding og garanti.
Preview Victron Energy Isolationstransformer 3600W Auto 115/230V Brugermanual
This user manual provides comprehensive information on the Victron Energy Isolation Transformer 3600W Auto 115/230V, including safety instructions, features, installation guide, operation details, technical specifications, and dimensional drawings. It is designed to enhance electrical safety and prevent galvanic corrosion on vessels.