1. Introduktion
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your BILT HARD Dual Fuel Inverter Generator, model TGA-0256. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
The BILT HARD TGA-0256 is a portable dual-fuel inverter generator designed to provide clean, stable power for various applications, including home backup, camping, RV use, and job sites. It operates on both gasoline and propane, offering versatility and convenience.
Billede 1.1: Forside view of the BILT HARD TGA-0256 Dual Fuel Inverter Generator.
2. Sikkerhedsoplysninger
ADVARSEL: Manglende overholdelse af disse sikkerhedsinstruktioner kan resultere i alvorlig personskade eller død.
- Kuliltefare: Generators produce carbon monoxide (CO), an odorless, colorless, and poisonous gas. Operate the generator outdoors only, far away from windows, doors, and vents. Never operate in an enclosed area.
- CO-sensor: This generator is equipped with a Carbon Monoxide (CO) sensor that automatically shuts down the engine if unsafe levels of CO are detected. Do not disable or bypass this safety feature. If the CO sensor activates, move the generator to a well-ventilated area and allow it to clear before restarting.
- Brandfare: Gasoline and propane are highly flammable. Store fuel in approved containers in a well-ventilated area. Do not refuel while the engine is running or hot. Keep flammable materials away from the generator.
- Fare for elektrisk stød: Do not operate the generator in wet conditions. Ensure all electrical connections are secure and properly grounded. Never touch bare wires or receptacles with wet hands.
- Varme overflader: Generatorens motor og lyddæmper bliver meget varme under drift og forbliver varme i et stykke tid efter nedlukning. Undgå kontakt for at forhindre forbrændinger.
- Korrekt jording: Always ground the generator properly before use to prevent electrical shock. Refer to local electrical codes for grounding requirements.
- Børn og kæledyr: Hold altid børn og kæledyr væk fra generatoren.
Image 2.1: Illustration of the Carbon Monoxide Auto-Shutoff system, showing automatic shutdown and service indicators.
3. Produktet er slutview og komponenter
Familiarize yourself with the main components and control panel of your BILT HARD TGA-0256 generator.
Billede 3.1: Detaljeret view of the generator's control panel, indicating the location of the CO Sensor, Engine Switch, Output/Overload/Oil Alert Indicators, Fuel Selector Switch, Economy Switch, Circuit Breakers, Dual USB Ports, 12V DC Port, AC Outlets (120V 20A Duplex, 120V 30A RV), Parallel Connectors, and Ground Terminal.
Nøglekomponenter:
- Motorafbryder: Controls engine operation (ON/OFF).
- Brændstofvælgerkontakt: Allows selection between Gasoline and LPG (Propane) fuel sources.
- CO-sensor: Detects carbon monoxide levels and triggers automatic shutdown if necessary.
- Output Indicator (Green): Illuminates when the generator is producing power.
- Overload Indicator (Red): Illuminates if the generator is overloaded.
- Oil Alert Indicator (Red): Illuminates if the oil level is low.
- Economy Switch: Engages ECO mode to adjust engine speed based on load, saving fuel and reducing noise.
- AC 120V 20A Duplex Receptacle (NEMA 5-20R): Standard stikkontakter i husholdningen.
- AC 120V Max 30A RV Receptacle (TT-30R): For RV and higher power applications.
- Dual USB Ports (Type A & C): For charging sensitive electronic devices.
- 12V 8A DC-udgang: For 12V DC appliances.
- Afbrydere: Protect outlets from overload.
- Parallelle stik: For connecting two compatible generators to double power output (parallel kit sold separately).
- Jordterminal: For proper grounding of the generator.
4. Opsætning
4.1 Udpakning
Tag forsigtigt generatoren ud af emballagen. Undersøg den for eventuelle transportskader. Gem emballagen til senere opbevaring eller transport.
4.2 Påfyldning af motorolie
The generator is shipped without engine oil. Before first use, add the recommended amount and type of oil. Refer to the engine section of this manual for oil specifications and capacity. Do not overfill.
4.3 Brændstofpåfyldning af generatoren
- Benzin: Use fresh, unleaded gasoline with an octane rating of 87 or higher. Fill the fuel tank carefully, avoiding spills. Do not fill above the red indicator line.
- Propan (LPG): Connect the provided propane hose with regulator to a standard propane tank and to the generator's LPG inlet. Ensure all connections are tight to prevent leaks.
WARNING: Never mix oil with gasoline. Always refuel in a well-ventilated area with the engine off and cool.
4.4 Jordforbindelse af generatoren
Connect a ground wire from the generator's ground terminal to a suitable earth ground (e.g., a ground rod). Consult local electrical codes for specific grounding requirements.
5. Betjeningsvejledning
5.1 Start af generatoren
- Ensure the generator is on a level surface and properly grounded.
- Afbryd alle elektriske belastninger fra generatoren.
- Select the desired fuel type using the Brændstofvælgerkontakt (Gas or LPG).
- Drej på Motorafbryder to the 'ON' position.
- If starting on gasoline, pull the choke lever to the 'CHOKE' position (if engine is cold).
- Træk fast i håndtaget til rekylstarteren, indtil motoren starter.
- Once the engine starts, slowly push the choke lever back to the 'RUN' position (if used).
- Allow the engine to run for a few minutes to warm up before connecting electrical loads.
5.2 Standsning af generatoren
- Afbryd alle elektriske belastninger fra generatoren.
- Drej på Motorafbryder to the 'OFF' position.
- Hvis du bruger propan, skal du lukke ventilen på propantanken.
5.3 Using ECO Mode
De Økonomi Switch allows the generator to adjust engine speed to match the load, improving fuel efficiency and reducing noise. To activate, turn the Economy Switch to 'ON'. For full power output or when starting high-load appliances, turn the Economy Switch to 'OFF'.
Image 5.1: Close-up of the Economy Mode switch, showing ON and OFF positions.
5.4 Tilslutning af elektriske belastninger
Once the generator is running stably, you can connect your electrical devices to the appropriate outlets. Ensure the total wattage of connected devices does not exceed the generator's rated wattage.
Image 5.2: The BILT HARD generator connected to an RV, demonstrating the use of the 30 Amp RV outlet.
5.5 Parallel drift
The BILT HARD TGA-0256 generator is parallel capable, allowing you to connect two identical units (with a parallel kit, not included) to double the power output. Follow the instructions provided with your parallel kit for safe connection and operation.
Image 5.3: Two BILT HARD generators connected for parallel operation, doubling the available power.
6. Vedligeholdelse
Regular maintenance is crucial for the longevity and reliable performance of your generator.
6.1 Vedligeholdelsesplan
| Punkt | Før hver brug | Every 25 Hours / Monthly | Every 100 Hours / Annually |
|---|---|---|---|
| Tjek motoroliestanden | ✓ | ||
| Ren luftfilter | ✓ | ||
| Inspicer tændrøret | ✓ | ||
| Skift motorolie | ✓ | ||
| Inspicer brændstoffilteret | ✓ |
6.2 Opbevaring
For long-term storage, prepare the generator as follows:
- Drain the fuel tank and carburetor of gasoline, or add a fuel stabilizer.
- Skift motorolien.
- Fjern tændrøret og hæld en lille mængde motorolie i cylinderen. Træk i rekylstarteren et par gange for at fordele olien, og sæt derefter tændrøret i igen.
- Rengør generatorens yderside.
- Opbevares rent, tørt og godt ventileret, væk fra direkte sollys og ekstreme temperaturer.
7. Fejlfinding
Dette afsnit omhandler almindelige problemer, du kan støde på med din generator.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Motoren vil ikke starte | No fuel or incorrect fuel type selected | Add fresh fuel; ensure correct fuel type is selected. |
| Lav motorolie | Add engine oil to the correct level. | |
| Tændrøret er snavset eller beskadiget | Rengør eller udskift tændrøret. | |
| Ingen strømudgang | Strømafbryder udløst | Reset the circuit breaker. Reduce load. |
| Overload indicator illuminated | Reducer den tilsluttede belastning. | |
| Engine runs, but no power | ECO mode engaged with high load | Turn ECO mode off for full power. |
| CO Sensor light on / Engine shuts off | Høje niveauer af kulilte registreret | Move generator to a well-ventilated outdoor area. Allow to clear before restarting. |
8. Specifikationer
Detailed technical specifications for the BILT HARD TGA-0256 Dual Fuel Inverter Generator.
| Feature | Specifikation |
|---|---|
| Model | TGA-0256 |
| Motortype | 141cc OHV 4-Stroke |
| Brændstoftype | Gasoline / Propane (LPG) |
| Gasoline Peak Watts | 4500 watt |
| Gasoline Rated Watts | 3500 watt |
| Propane Peak Watts | 4150 watt |
| Propane Rated Watts | 3200 watt |
| Voltage | 120 volt (AC) |
| Total harmonisk forvrængning (THD) | <3 % |
| Noise Level (at 23 ft) | 58 dBA |
| Brændstoftankvolumen | 1.37 Imperial Gallons (Gasoline) |
| Startsystem | Rekyl start |
| Produktmål (L x B x H) | 21.4 cm x 12.7 cm x 19.3 cm |
| Varens vægt | 57.6 pund |
| Særlige funktioner | CO Sensor, Dual Fuel, Portable, USB Port, Parallel Capable |
Image 8.1: Dimensional drawing of the BILT HARD TGA-0256 generator, showing its length, width, and height.
9. Garanti og support
BILT HARD products are designed for durability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official BILT HARD webwebsted. Gem din købskvittering som købsbevis i tilfælde af garantikrav.
Kundesupport:
If you have questions, require technical assistance, or need to order replacement parts, please contact BILT HARD customer support. Contact information can typically be found on the product packaging, the official webwebstedet eller garantidokumentationen.
For online resources and additional product information, you may visit the BILT HARD Store on Amazon.