INKBIRDPLUS HD08 / HD05

Brugermanual: HD08 Kulilte- og HD05 Naturgaslækagedetektor

Mærke: INKBIRDPLUS

Modeller: HD08 (Carbon Monoxide Detector), HD05 (Natural Gas Leak Detector)

1. Introduktion

This user manual provides essential information for the safe and effective operation of your INKBIRDPLUS HD08 Carbon Monoxide Detector and HD05 Natural Gas Leak Detector. These devices are designed to monitor gas quality, temperature, and humidity, providing real-time alerts to ensure the safety of your home or other applicable environments.

Læs venligst denne manual grundigt inden installation og brug, og gem den til senere brug.

2. Sikkerhedsoplysninger

WARNING: This device is intended to detect carbon monoxide (CO) and natural gas. It is not designed to detect smoke, fire, or other gases. It is not a substitute for proper ventilation and maintenance of fuel-burning appliances.

  • Do not paint the detector. Paint can clog the vents and interfere with the sensor's ability to detect gases.
  • Do not block the air vents on the detector. Ensure proper airflow around the device.
  • Regularly test the alarm as instructed in the "Operating Instructions" section.
  • If the alarm sounds, immediately move to fresh air and call emergency services. Do not re-enter the premises until it has been deemed safe by professionals.
  • The detector should be plugged into a standard wall outlet. Do not use extension cords or power strips.
  • Opbevares utilgængeligt for børn.
  • Ensure the device is installed in an appropriate location as per local regulations and safety guidelines for gas detectors.

3. Produktet er slutview

3.1 Nøglefunktioner

  • 2.1" Digital Display & Warning: Features an HD 2.1" IPS display and high accuracy CO sensor, refreshing every 2 seconds for quick detection. Includes an 85 dB alarm and a fast flashing indicator light.
  • Nem installation: Plug-and-play design with a simple, stylish appearance. Small size for portability, no complex installation required. Ready to monitor after a brief warm-up.
  • Premium Quality for Safety: Complies with UL safety standards, designed to be eco-friendly, and provides sensitive detection for family safety.
  • 24/7 Monitoring & Applicable Scenes: The gas alarm monitor features a 3D porous air duct design for accurate CO/natural gas detection, offering all-day protection. Suitable for various locations including bedrooms, kitchens, living rooms with stoves, wood fireplaces, bathrooms, apartments, garages, offices, restaurants, hotels, and RVs.

3.2 Components and Display

INKBIRDPLUS HD08 Carbon Monoxide Detector and HD05 Natural Gas Leak Detector side-by-side

Figur 1: HD08 Carbon Monoxide Detector (right) and HD05 Natural Gas Leak Detector (left).

HD08 Carbon Monoxide Detector display with labels for CO Monoxide, Temperature, and Humidity

Figur 2: HD08 Carbon Monoxide Detector display showing CO concentration (PPM), temperature (°F/°C), and humidity (%).

HD05 Natural Gas Leak Detector display with gas level bars, temperature, and humidity, showing dimensions

Figur 3: HD05 Natural Gas Leak Detector display showing gas concentration levels (bars), temperature (°F/°C), and humidity (%). Dimensions are approximately 2.05 inches wide by 3.39 inches high.

Both detectors feature a 2.1-inch HD IPS color screen display, providing clear and broad viewing angles for real-time readings of gas levels, temperature, and humidity. They are equipped with three function buttons: H, O, and D.

4. Opsætning

The INKBIRDPLUS HD08 and HD05 detectors are designed for simple plug-and-play operation.

  1. Unpack the detector from its packaging.
  2. Select a suitable standard wall socket for installation. For CO detectors, typically near sleeping areas and on every level of the home. For natural gas detectors, near gas appliances or potential leak sources, but not directly above them.
  3. Plug the alarm detector directly into the wall socket. The device will automatically power on and begin its warm-up process.
  4. Allow the device to complete its warm-up (typically a few minutes) before it starts real-time monitoring.
HD05 Natural Gas Leak Detector plugged into a wall socket in a kitchen setting

Figur 4: Detector plugged into a wall outlet, ready for monitoring various gas types including LNG, Propane, LPG, Coal Gas, and Methane.

5. Betjeningsvejledning

5.1 Knapfunktioner

The detectors feature three main function buttons: H, O, and D.

  • "O" Button (Center):
    • Kort tryk: Initiates a self-test of the alarm. If the device beeps 3 times, it indicates normal operation.
    • Langt tryk: Toggles the temperature display unit between Fahrenheit (°F) and Celsius (°C).
  • "H" Button (Left): Adjusts the screen brightness. There are three brightness modes: High, Low, and Backlight Off.
  • "D" Button (Right): Toggles the 85 dB alarm sound on or off.
Finger pressing the 'O' button on the HD08 Carbon Monoxide Detector for self-test, showing green and red indicator lights

Figur 5: Self-test operation on the HD08 CO Detector. A green light indicates normal operation, while a red light signifies an error or sensor malfunction.

Finger pressing the 'O' button on the HD05 Natural Gas Leak Detector for self-test, showing green and red indicator lights

Figur 6: Self-test operation on the HD05 Natural Gas Detector. A green light indicates normal operation, while a red light signifies an error or sensor malfunction.

5.2 Vis information

The 2.1-inch HD color screen provides real-time data:

  • CO (Carbon Monoxide) / GAS: Displays the concentration of carbon monoxide in parts per million (PPM) for the HD08, or a bar graph indicating gas levels for the HD05.
  • Temperatur: Shows the ambient temperature in either Fahrenheit (°F) or Celsius (°C).
  • Fugtighed: Displays the relative humidity percentage (%).
  • Indikatorlys:
    • Green Light (Screen off and indicator light on): Indicates normal operation and continuous monitoring of CO or combustible gas concentration.
    • Red Light (Alarm): Indicates a mute error, sensor malfunction, or an active alarm due to detected gas levels.
Close-up of the 2.1 inch HD color screen display of the detector, showing CO PPM, temperature, and humidity

Figur 7: The 2.1-inch HD IPS display provides clear readings with ultra-broad perspective and 240x296 resolving power.

6. Vedligeholdelse

To ensure the optimal performance and longevity of your INKBIRDPLUS detectors, follow these maintenance guidelines:

  • Regelmæssig test: Perform a self-test (short press "O" button) at least once a month to ensure the alarm and sensor are functioning correctly.
  • Rensning: Tør forsigtigt detektorens yderside af med en blød kludamp cloth. Do not use harsh chemicals, abrasive cleaners, or spray directly onto the device. Ensure the air vents are free from dust and debris.
  • Undgå forhindringer: Ensure nothing is blocking the air vents or the display screen.
  • Miljøforhold: Keep the detector within recommended operating temperature and humidity ranges to prevent sensor degradation.
Underside view of the detector showing the 3D porous air duct design

Figur 8: The 3D porous air duct design facilitates accurate gas detection and should be kept clear.

7. Fejlfinding

Problem Mulig årsag Løsning
Alarm sounds (Red light flashing, 85 dB beep) High concentration of CO (HD08) or natural gas (HD05) detected.
  • Immediately move to fresh air.
  • Do not re-enter the premises until it has been deemed safe by emergency services or qualified professionals.
  • Call your local emergency services or gas company.
Red light is on, but no alarm sound (if alarm is enabled) Mute error or sensor malfunction.
  • Perform a self-test (short press "O" button).
  • Unplug the device, wait 30 seconds, and plug it back in.
  • Kontakt kundesupport, hvis problemet fortsætter.
Display is blank or not functioning Ingen strøm eller fejl på enheden.
  • Ensure the device is securely plugged into a live wall socket.
  • Prøv en anden stikkontakt.
  • Kontakt kundesupport, hvis problemet fortsætter.

8. Specifikationer

  • Produktnavn: Carbon Monoxide Detectors + Natural Gas Leak Detector
  • Modeller: HD08 (Carbon Monoxide), HD05 (Natural Gas)
  • Vise: 2.1" HD IPS Color Screen
  • Alarmstyrke: 85 dB
  • Input bindtage: AC 110-220V/50-60Hz
  • Arbejdsstrøm: 0.5A Maks
  • Overholdelse: UL Safety Standards
  • Dimensioner: Approximately 2.05 inches (W) x 3.39 inches (H) (as per image)
  • Første tilgængelige: 10. april 2025

9. Garanti og support

For warranty information or technical support, please contact INKBIRDPLUS customer service. Refer to the product packaging or the official INKBIRDPLUS webhjemmeside for de seneste kontaktoplysninger.

INKBIRDPLUS Customer Service: Please visit the official INKBIRDPLUS website or refer to your purchase documentation for support contact information.

Relaterede dokumenter - HD08 / HD05

Preview INKBIRDPLUS HS-16 metaldetektor brugermanual og brugervejledning
Detaljeret brugermanual til INKBIRDPLUS HS-16 metaldetektoren, en vandtæt håndholdt enhed med LCD-skærm. Dækker funktioner, specifikationer, betjening og batteriudskiftning for effektiv metaldetektion.
Preview INKBIRDPLUS PTH-9A Multifunktionsluftkvalitetsdetektor Brugermanual
Omfattende brugermanual til INKBIRDPLUS PTH-9A multifunktionsluftkvalitetsdetektor, der dækker produktintroduktion, specifikationer, betjeningsvejledning, indstilling af tid/dato og garantioplysninger. Overvåger PM2.5, PM10, CO2, temperatur og luftfugtighed.
Preview Brugermanual til Gedsffati HD08-G kombineret gas- og kuliltedetektor
Brugermanual til Gedsffati HD08-G kombineret gas- og kuliltedetektor. Indeholder instruktioner om betjening, alarmfunktioner, tekniske specifikationer og sikkerhedsforanstaltninger til overvågning af luftkvalitet.
Preview HD08-G Combined Combustible Gas and Carbon Monoxide Detector User Manual
Comprehensive user manual for the HD08-G detector, covering setup, operation, technical specifications, safety precautions, and warranty information for combustible gas and carbon monoxide detection.
Preview HD08 Kuliltedetektor Brugermanual
Omfattende brugermanual til HD08 kuliltedetektoren, der indeholder detaljerede instruktioner om betjening, funktioner, specifikationer og sikkerhedsforanstaltninger. Lær, hvordan du bruger og vedligeholder din CO-detektor for optimal ydeevne og sikkerhed.
Preview Brugermanual til Gedsffati HD08-G kombineret gas- og kuliltedetektor
The Gedsffati HD08-G is a combined gas and carbon monoxide detector designed for home safety. It features a digital display showing CO and combustible gas concentrations, temperature, and humidity. The device provides audible and visual alarms for dangerous gas levels and includes user-friendly controls for temperature unit switching, buzzer activation, and screen brightness adjustment. This manual provides detailed instructions, technical specifications, and safety precautions for optimal use.