Intermatic ETW2CP

Intermatic ETW2CP Wi-Fi Smart Timer Brugsanvisning

Model: ETW2CP

1. Introduktion

This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic ETW2CP Wi-Fi Smart Timer. The ETW2CP is a 2-circuit, 365-day programmable timer designed for automating lights, pumps, and industrial equipment. It features remote control via the Intermatic Connect app and is suitable for both indoor and outdoor applications.

2. Sikkerhedsoplysninger

ADVARSEL: Risk of electric shock. Installation and servicing must be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse before installing or servicing. Follow all local and national electrical codes.

3. Produktet er slutview

The Intermatic ETW2CP is a sophisticated Wi-Fi enabled timer offering precise control over two independent circuits. Key features include:

Intermatic ETW2CP Wi-Fi Smart Timer with cover open

Figure 1: Intermatic ETW2CP Wi-Fi Smart Timer with its cover open, showing the internal components and control panel. The left side of the enclosure displays product specifications and warnings, while the right side features control buttons, indicator LEDs, and terminal blocks for wiring connections.

Close-up of Intermatic ETW2CP control panel and wiring terminals

Figur 2: En detaljeret view of the ETW2CP's control panel. Visible elements include the MODE button, SERVICE, MANUAL, and AUTO indicator LEDs, NETWORK status LED, RESET button, and two circuit control buttons (1 and 2). Below these are the terminal blocks for power input (L2/H, L1, NC, NO, COM) and two independent circuits (CIRCUIT 1, CIRCUIT 2).

4. Opsætning og installation

4.1 Montering af timeren

The ETW2CP timer is designed for surface mounting. Select a suitable location that allows for proper wiring and access. Ensure the mounting surface is stable and can support the weight of the timer.

  1. Open the timer enclosure by unlatching the cover.
  2. Use the provided mounting holes on the back of the enclosure as a template to mark drilling locations.
  3. Drill appropriate pilot holes and secure the timer to the wall using suitable screws (not included).
  4. Ensure the enclosure is level and securely fastened.
Intermatic ETW2CP timer with cover closed, front view

Figur 3: Forside view of the Intermatic ETW2CP Wi-Fi Smart Timer with its cover closed, displaying the Intermatic logo. This image shows the compact and sealed design of the enclosure.

4.2 Ledningsinstruktioner

VIGTIG: All wiring must comply with national and local electrical codes. Disconnect power before proceeding.

  1. Route power supply wires into the enclosure through appropriate knockouts.
  2. Tilslut den indgående linje voltage (120-277 VAC) to the L1 and L2/H terminals.
  3. Connect the neutral wire to the N terminal (if applicable for your wiring configuration).
  4. Connect the load wires for Circuit 1 to the appropriate terminals (NO, NC, COM) for Circuit 1.
  5. Connect the load wires for Circuit 2 to the appropriate terminals (NO, NC, COM) for Circuit 2.
  6. Ensure all terminal screws are tightened securely.
  7. Close and latch the enclosure cover.
Side view of Intermatic ETW2CP timer showing conduit knockouts

Figur 4: Side view of the Intermatic ETW2CP timer, highlighting the conduit knockouts for electrical wiring entry. This view demonstrates the robust construction and provisions for secure cable management.

4.3 Initial Power-Up and Wi-Fi Connection

  1. Restore power to the timer at the circuit breaker.
  2. Download the "Intermatic Connect" app from your device's app store.
  3. Follow the in-app instructions to create an account and add your ETW2CP timer to your network. The NETWORK LED on the timer will indicate connection status.

5. Betjeningsvejledning

5.1 Manuel kontrol

The ETW2CP allows for manual override of the scheduled programs.

5.2 App-Based Scheduling

All advanced scheduling and programming are managed through the Intermatic Connect app.

  1. Open the Intermatic Connect app on your smartphone or tablet.
  2. Select your ETW2CP timer from the device list.
  3. Navigate to the "Schedules" section to create, edit, or delete ON/OFF events and holiday schedules.
  4. Use the app to set astronomical clock functions, daylight saving adjustments, and other advanced settings.
  5. The app also provides real-time status updates and remote ON/OFF control for each circuit.

6. Vedligeholdelse

The Intermatic ETW2CP Wi-Fi Smart Timer requires minimal maintenance.

7. Fejlfinding

ProblemMulig årsagLøsning
Timeren tænder ikke.No power at the circuit breaker; incorrect wiring.Check circuit breaker. Verify wiring connections according to Section 4.2.
Kan ikke oprette forbindelse til Wi-Fi.Incorrect Wi-Fi password; router too far; network issues.Ensure correct password. Move timer closer to router or use a Wi-Fi extender. Restart router. Press the RESET button on the timer.
Schedules are not activating loads.Timer is in MANUAL or SERVICE mode; incorrect schedule programming.Ensure timer is in AUTO mode. Verify schedules in the Intermatic Connect app.
App shows timer offline.Loss of internet connection; timer lost power; Wi-Fi signal lost.Check internet connection. Verify timer has power. Check Wi-Fi signal strength at timer location.

If issues persist, contact Intermatic Customer Support.

8. Specifikationer

FeatureDetalje
ModelETW2CP
Input bindtage120-277 VAC, 50/60 Hz (Auto-detecting)
Udgangsrelæer2 x SPDT (Single-Pole Double-Throw)
Maksimal belastning (resistiv)30A per circuit @ 120-277 VAC
Motorbelastning2 HP @ 120 VAC; 5 HP @ 240 VAC
IndkapslingsmaterialePlast
Dimensioner11 cm D x 14 cm B x 10.75 cm H (ca.)
Driftstemperatur-40°F til 140°F (-40°C til 60°C)
ForbindelseWi-Fi (2.4 GHz)
Programmering365-day, up to 256 events, 64 holiday schedules

9. Garanti og support

For warranty information and technical support, please visit the official Intermatic webwebstedet eller kontakt deres kundeserviceafdeling. Behold din købskvittering som købsbevis.

Intermatic Webwebsted: www.intermatic.com

Relaterede dokumenter - ETW2CP

Preview Intermatic Connect ETW2CP/ETW3CP Smart Wi-Fi Timer: Installation and Setup Guide
Learn how to install and set up the Intermatic Connect ETW2CP and ETW3CP 365-day programmable smart Wi-Fi timers. This guide covers installation, wiring, and initial configuration for indoor and outdoor load control applications.
Preview Intermatic Connect 365-Day Programmable Smart Wi-Fi Timer ETW2CP ETW3CP Installation and Setup Guide
Comprehensive installation and setup guide for Intermatic Connect 365-Day Programmable Smart Wi-Fi Timers, models ETW2CP and ETW3CP. Covers safety warnings, product description, technical specifications, wiring diagrams, LED status indicators, and warranty information.
Preview Intermatic Programmerbar Smart Wi-Fi Pool Timer PE723P PE733P Installations- og opsætningsvejledning
Omfattende installations- og opsætningsvejledning til Intermatic PE723P og PE733P programmerbare smarte Wi-Fi-pooltimere. Lær, hvordan du installerer, tilslutter og konfigurerer disse smarte timere til belastningsstyring af indendørs og udendørs pools, inklusive specifikationer, sikkerhedsadvarsler og LED-indikatorer.
Preview Intermatic ET8215C Elektronisk Timerstyring - Tekniske Data
Detaljerede tekniske specifikationer for Intermatic ET8215C elektronisk timerstyring, en astronomisk 7-dages, 2-kreds elektronisk styring egnet til 120-277 VAC applikationer i et indendørs metalkabinet.
Preview Intermatic Ascend Timer Installation & Operation Manual (STW700W/ST700W)
Comprehensive installation and operation guide for Intermatic Ascend™ 7-Day timers, including models STW700W (Wi-Fi enabled) and ST700W (Standard). Covers setup, wiring, modes, scheduling, settings, troubleshooting, and warranty information.
Preview Intermatic Ascend STW700W/ST700W Timer: Installation and Operation Manual
Comprehensive guide to installing and operating the Intermatic Ascend Smart Wi-Fi Timer (STW700W) and Standard Timer (ST700W), covering setup, modes, scheduling, troubleshooting, and specifications.