Renogy RIV1230P2-126

Renogy 3000W 12V Pro Pure Sine Wave Inverter Instruction Manual

Model: RIV1230P2-126

1. Introduktion

The Renogy 3000W 12V Pro Pure Sine Wave Inverter converts 12V DC battery power into stable 110V/120V AC household electricity. This inverter is designed for reliable performance in various applications, including RVs, trucks, and off-grid home energy systems. Key features include a 3000W continuous power output, 6000W peak power, built-in Bluetooth for monitoring, an EcoSleep mode for energy conservation, and a remote controller for convenient operation.

Renogy 3000W 12V Pro Pure Sine Wave Inverter with remote control and cable

Figure 1: Renogy 3000W 12V Pro Pure Sine Wave Inverter with included remote control and communication cable.

2. Sikkerhedsoplysninger

Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electrical shock, fire, or serious injury.

  • The inverter is UL 458 & CSA C22.2 No. 107.1 certified, ensuring compliance with safety and quality standards.
  • Ensure the inverter chassis is properly grounded to prevent electrical hazards.
  • The inverter features pre-charging functionality to ensure a smooth start, protecting both the battery and the inverter from high peak currents during connection.
  • Dual-polarity reverse connection protection is integrated to prevent internal damage in case of accidental misconnection of battery positive and negative terminals. However, always verify correct polarity before making connections.
  • Be aware that the surge capacity of inductive appliances can exceed their continuous rating by 5 to 7 times. Plan your loads accordingly to avoid unexpected shutdowns.
  • Do not expose the inverter to rain, moisture, or excessive dust.
  • Brug inverteren i et godt ventileret område for at forhindre overophedning.
Diagram illustrating pre-charging and dual-polarity reverse protection features of the inverter

Figure 2: Inverter security features including pre-charging and dual-polarity reverse protection.

Renogy inverter with GFCI, FCC, and ETL certifications shown, with a boat in the background

Figure 3: Essential safety protections including GFCI, FCC, and ETL certifications.

3. Opsætning

3.1 Montering

Mount the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure there is adequate space around the inverter for proper airflow and cooling.

3.2 DC-indgangsforbindelse

Connect the inverter to your 12V battery bank. Use appropriate gauge cables for the power rating. The inverter is equipped with dual-polarity reverse connection protection, but it is crucial to always connect the positive (+) terminal of the inverter to the positive (+) terminal of the battery and the negative (-) terminal of the inverter to the negative (-) terminal of the battery. The pre-charging function will help protect the system during initial connection.

Person connecting battery cables to the inverter, highlighting reverse polarity protection

Figure 4: Connecting battery cables to the inverter, demonstrating reverse polarity protection.

3.3 AC-udgangsforbindelse

The inverter provides two standard AC sockets and one AC terminal block for connecting your AC loads. Ensure that the total continuous power draw of your appliances does not exceed 3000W. For permanent installations, use the AC terminal block following local electrical codes.

3.4 Tilslutning af fjernbetjening

Connect the included 16.4ft wired remote controller to the designated port on the inverter. This allows for convenient power control and monitoring from a distance.

Renogy remote controller for the inverter

Figure 5: The Renogy wired remote controller.

4. Betjeningsvejledning

4.1 Tænd/sluk

To power on the inverter, press the power button on the unit or the remote controller. The indicator lights will confirm operation. To power off, press the button again.

4.2 EcoSleep Mode

The intelligent EcoSleep mode conserves energy by automatically switching the inverter to a low-power sleep state when no load is detected. In this mode, idle power consumption is less than 10W. The inverter will automatically wake up when an AC load is connected or detected.

Renogy inverter with a smartphone displaying EcoSleep mode settings

Figure 6: Inverter operating in EcoSleep mode, showing smartphone monitoring interface.

Renogy inverter installed in an RV with EcoSleep mode indicator

Figure 7: Inverter in an RV setup, demonstrating EcoSleep mode activation.

4.3 Bluetooth Monitoring

The inverter features built-in Bluetooth connectivity, allowing for real-time monitoring via a compatible smartphone application. It also supports RV-C connectivity for seamless integration with Renogy One Core/M1 systems, providing enhanced control and convenience.

Smartphone screens displaying the Renogy inverter monitoring application

Figure 8: Real-time monitoring of the inverter via a smartphone application.

Diagram showing the inverter powering various RV appliances like TV, coffee maker, air conditioner, microwave, and portable freezer

Figur 9: Eksample of RV appliances powered by the inverter.

5. Vedligeholdelse

Regelmæssig vedligeholdelse sikrer din inverters levetid og optimale ydeevne.

  • Hold inverteren ren og fri for støv og snavs. Brug en tør klud til rengøring.
  • Ensure all electrical connections, especially battery terminals, are tight and free from corrosion.
  • Verify that the ventilation openings are not blocked to allow for proper heat dissipation.
  • The inverter supports multiple battery types including GEL, AGM, SLA, FLD, and Lithium (LI). Ensure your battery settings are correctly configured if applicable.

6. Fejlfinding

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific error codes or persistent problems, contact Renogy customer support.

  • Ingen strømudgang: Check battery connections for tightness and correct polarity. Verify battery voltage is within the inverter's operating range. Ensure the inverter is powered on.
  • Lav AC-udgangsvolumentage: Kontroller DC input voltage from the battery. Ensure the load is not exceeding the inverter's continuous power rating.
  • Overbelastningsindikation: Reduce the number of connected AC appliances. Disconnect high-power inductive loads that may cause surge spikes.
  • Overophedning: Ensure the inverter is in a well-ventilated area. Clear any obstructions from the cooling fans. Reduce the load if operating in high ambient temperatures.

7. Specifikationer

FeatureSpecifikation
Modelnavn3000W Pure Sine Wave Inverter Pro
VaremodelnummerRIV1230P2-126
Kontinuerlig strømudgang3000W
Spidseffekt6000W
DC Input Voltage12V
AC Output Voltage110V/120V
KonverteringseffektivitetOp til 90 %
Effektivitet ved fuld belastningExceeding 87%
Idle Power Consumption (EcoSleep Mode)< 10W
Total harmonisk forvrængning (THD)< 2 %
AC -stik2
AC klemmeblok1
Remote Controller Cable Length16.4 fod
Produktmål (L x B x H)19.5 x 9.2 x 4.2 tommer
Varens vægt16.6 pund
CertificeringerUL 458, CSA C22.2 No. 107.1, FCC, ETL
Diagram showing the dimensions of the Renogy 3000W Pure Sine Wave Inverter Pro

Figure 10: Inverter dimensions.

Comparison table of Renogy P2 PRO Series vs. Renogy P2 Series inverters

Figure 11: Feature comparison between Renogy P2 PRO Series and P2 Series inverters.

8. Garanti og support

8.1 Garanti

The Renogy 3000W 12V Pro Pure Sine Wave Inverter comes with a 3-year warranty. For any issues encountered within this period, please contact Renogy customer support.

8.2 Kundesupport

Renogy is committed to providing excellent customer service. Support includes:

  • 24-hour prompt response to inquiries.
  • Access to local warehouses in the US for efficient service.
  • Professional technical guidance to assist with installation, operation, and troubleshooting.
Icons representing Renogy customer support features: 24-hour response, local warehouses, professional technical guidance, and 15 years of experience

Figure 12: Renogy customer support services.

Relaterede dokumenter - RIV1230P2-126

Preview Renogy RIV1230P2-126 Pro 3000W 12V ren sinusbølge inverter brugermanual
Omfattende brugermanual til Renogy RIV1230P2-126 Pro 3000W 12V ren sinusbølgeinverter med EcoSleep-tilstand, der dækker funktioner, specifikationer, installation, betjening og sikkerhedsretningslinjer.
Preview Renogy 3000W 12V Pro ren sinusbølge inverter brugermanual
Omfattende brugermanual til Renogy 3000W 12V Pro Pure Sine Wave-inverteren, med detaljerede oplysninger om installation, betjening, sikkerhedsretningslinjer, specifikationer og fejlfinding. Har EcoSleep-tilstand for energieffektivitet.
Preview Renogy 12V 3000W Pro ren sinusbølge inverter brugermanual
Brugermanual til Renogy 12V 3000W Pro Pure Sine Wave-inverteren, der indeholder vigtige oplysninger om drift, vedligeholdelse og sikkerhed. Lær om produktfunktioner, ansvarsfraskrivelser og varemærker.
Preview Renogy 12V ren sinusbølgeinverter med omskifter brugermanual
This user manual provides comprehensive instructions for the Renogy 12V Pure Sine Wave Inverter with Transfer Switch, available in 1000W, 2000W, and 3000W models. It covers installation, operation, safety precautions, troubleshooting, and technical specifications for off-grid applications.
Preview Renogy 12V ren sinusbølgeinverter Core-serien - Tekniske specifikationer og funktioner
Udforsk Renogy 12V Pure Sine Wave Inverter Core-serien, der byder på effektiv strømkonvertering, støjsvag drift og avancerede sikkerhedsfunktioner. Ideel til off-grid-systemer. Indeholder tekniske specifikationer for RIV1210PU-126, RIV1220PU-126 og RIV1230PU-126 modellerne.
Preview Renogy 12V ren sinusbølgeinverter med omskifter brugermanual
Omfattende brugermanual til Renogy 12V ren sinusbølge-invertere (1000W, 2000W, 3000W) med omskifter, der dækker installation, betjening, sikkerhed, fejlfinding og specifikationer.