Indledning
Thank you for choosing the SKINACT Bellage Electric Treatment Table. This versatile and durable electric chair is designed for professional use in spa and medical environments, offering exceptional comfort and adjustability. Equipped with four independent electric motors, it allows for precise positioning of the backrest, leg rest, seat tilt, and overall height, ensuring optimal client comfort and practitioner convenience. This manual provides essential information for the safe and effective setup, operation, and maintenance of your new treatment table.

Figur 1: Overview of the SKINACT Bellage Electric Treatment Table with key features labeled.
Sikkerhedsoplysninger
Please read all safety warnings and instructions carefully before assembly and operation. Failure to do so may result in injury or damage to the product. Ensure the table is placed on a stable, level surface. Keep hands and loose clothing clear of moving parts during operation. Do not exceed the maximum weight capacity of 350 lbs. Disconnect power before performing any maintenance or cleaning.
Opsætning
1. Udpakning og placering
- Fjern forsigtigt alle komponenter fra emballagen.
- Place the base of the treatment table on a firm, level floor. Ensure there is sufficient clear space around the table for full range of motion and safe operation.
- Verify all leveling feet on the base are properly adjusted to ensure stability.
2. Komponentsamling
- Attach Headrests: The Bellage table comes with two different headrests. Select the appropriate headrest for your procedure and securely attach it to the head section of the table. One headrest includes a breather hole for clients lying face down.
- Fastgør armlæn: Slide the removable armrests into their designated slots on the sides of the main body of the chair.
- Foot Rest Extension: The foot rest section can be extended as needed.

Figure 2: The two interchangeable headrests provided with the table.
3. Strømtilslutning
- Locate the power cord and plug it securely into the power input on the table's base.
- Plug the other end of the power cord into a grounded electrical outlet (100-120 volts, 50-60 hertz).
4. Fjernbetjeningsforbindelse
- Connect the remote control cable to the designated port on the underside of the table.

Figure 3: The wired remote control for the Bellage Electric Treatment Table.
Demonstrationsvideo af opsætning
Video 1: A demonstration of the Bellage Electric Treatment Table's features and adjustments.
Betjeningsvejledning
The SKINACT Bellage Electric Treatment Table is operated using the wired remote control. Each button on the remote corresponds to a specific motor, allowing for independent adjustment of different sections of the table.
1. Tænd/sluk
- Tryk på Magt button (usually indicated by a circle with a vertical line) on the remote to turn the table on or off.
2. Justering af højden
- Brug Op/Ned pile associated with the overall table icon to raise or lower the table's height. The height can be adjusted between 25.5 and 31.5 inches.

Figure 4: Electric height adjustment.
3. Adjusting Backrest Angle
- Brug Op/Ned pile associated with the backrest icon to adjust the backrest angle from 0° to 80° incline.

Figure 5: Electric backrest adjustment.
4. Adjusting Leg Rest Angle
- Brug Op/Ned pile associated with the leg rest icon to adjust the leg rest angle from 0° to 85° decline.

Figure 6: Electric leg rest adjustment.
5. Adjusting Bed Tilt Angle
- Brug Op/Ned pile associated with the full bed tilt icon to adjust the entire bed's tilt angle from 0° to 10°.

Figure 7: Electric bed tilt adjustment.
6. Memory Presets (P1, P2, P3)
- The remote control may feature preset buttons (P1, P2, P3) to save and recall preferred positions. Consult the remote's specific instructions for programming these presets.
Opretholdelse
Regular maintenance ensures the longevity and optimal performance of your SKINACT Bellage Electric Treatment Table.
- Rensning: Wipe the surfaces of the table with a dry cloth. For deeper cleaning, use a mild, non-abrasive cleaner and a soft cloth. Avoid harsh chemicals or abrasive materials that could damage the upholstery or frame.
- Inspektion: Periodically inspect all electrical cords, connections, and moving parts for any signs of wear, damage, or loose fittings. If any issues are found, discontinue use and contact customer support.
- Smøring: The electric motors and moving mechanisms are generally maintenance-free. Do not attempt to lubricate internal components unless specifically instructed by a qualified technician.
Fejlfinding
If you encounter any issues with your treatment table, refer to the following common troubleshooting steps:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Table does not respond to remote control. | No power; Loose connection; Remote control malfunction. | Check if the power cord is securely plugged into the outlet and the table. Ensure the remote control cable is firmly connected. Try a different outlet. If the issue persists, contact customer support. |
| Motor makes unusual noise or movement is jerky. | Obstruction; Motor issue. | Check for any obstructions preventing smooth movement. Ensure the table is not overloaded. Discontinue use and contact customer support if the noise or jerky movement continues. |
| Bordet er ustabilt eller vakler. | Uneven floor; Unadjusted leveling feet. | Ensure the table is on a flat, level surface. Adjust the leveling feet on the base until the table is stable. |
Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | SKINACT |
| Modelnummer | SKU164247 |
| Materiale | Metal frame, plastic cover, Foam, PU upholstery |
| Farve | Mørkegrå |
| Varens vægt | 200 pund |
| Produktmål (L x B x H) | 68 x 28 x 32 tommer |
| Length (with headrest) | 76.8 tommer |
| Højdeområde | 25.5 / 31.5 tommer |
| Width (with armrests) | 35.4 inches (24.8 inches without armrests) |
| Ryglænets vinkel | 0° to 80° incline |
| Bed Tilt Angle | 0° til 10° |
| Leg Rest Angle | 0° to 85° decline |
| Strømkrav | 100-120 volts, 50-60 hertz, 200 watts, 2 amp |
| Maksimal vægtkapacitet | 350 lbs. |

Figure 8: Detailed dimensions of the treatment table.
Garanti & Support
The SKINACT Bellage Electric Treatment Table comes with a ET ÅRS GARANTI fra købsdatoen. Denne garanti dækker fabrikationsfejl og funktionsfejl under normal brug.
For technical support, warranty claims, or any questions regarding your product, please contact SKINACT customer service. Refer to your purchase documentation for specific contact details or visit the official SKINACT webwebsted.