APC BE1050G2-GR

APC Back-UPS BE1050G2-GR Brugermanual til nødstrømsforsyning

Model: BE1050G2-GR

1. Introduktion

The APC Back-UPS BE1050G2-GR is an Uninterruptible Power Supply (UPS) designed to provide battery backup and surge protection for your electronic devices. In the event of a power outage, this unit ensures instant power to connected equipment, allowing for safe shutdown or continued operation. It also protects against harmful voltage fluctuations and provides USB charging capabilities.

This manual provides essential information for the safe and efficient use of your APC Back-UPS BE1050G2-GR. Please read it thoroughly before installation and operation.

2. Vigtige sikkerhedsinstruktioner

WARNING: Risk of Electric Shock. Do not open the UPS enclosure. There are no user-serviceable parts inside.

Overhold følgende sikkerhedsforanstaltninger under installation og drift:

  • Denne UPS er kun beregnet til indendørs brug.
  • Brug ikke denne UPS i direkte sollys, i kontakt med væsker, eller hvor der er meget støv eller fugt.
  • Connect the UPS power cable directly to a wall outlet. Do not use extension cords or surge protectors with the UPS input.
  • Ensure the total current draw of equipment connected to the UPS does not exceed the unit's capacity.
  • Service af batterier skal udføres eller overvåges af personale, der har viden om batterier og de nødvendige forholdsregler. Hold uautoriseret personale væk fra batterier.
  • Dispose of batteries properly. Refer to local regulations for disposal requirements.

3. Pakkens indhold

Bekræft, at din pakke indeholder følgende varer:

  • APC Back-UPS BE1050G2-GR-enhed
  • Brugervejledning (dette dokument)
  • USB Communication Cable (if applicable)

If any items are missing or damaged, please contact your dealer or APC customer support.

4. Produktet er slutview

The APC Back-UPS BE1050G2-GR features multiple outlets for connecting your devices, including battery backup and surge-protected outlets, as well as USB charging ports.

Top-down view of the APC Back-UPS BE1050G2-GR showing 8 Schuko outlets, 2 USB charging ports, and control panel.

Figur 4.1: Øverst view of the APC Back-UPS BE1050G2-GR, highlighting the 8 Schuko CEE 7/3 sockets, two USB charging ports, and the power/status indicators.

Vinklet view of the APC Back-UPS BE1050G2-GR showing the unit's design and port layout.

Figur 4.2: Vinklet view of the APC Back-UPS BE1050G2-GR, providing a perspective of the overall unit and its connections.

4.1 Frontpanelfunktioner

  • Power knap: Tænder eller slukker UPS'en.
  • Statusindikatorer: LEDs that display the UPS operational status, battery charge level, and power conditions.
  • USB -opladningsporte: Two 5V, 2.4A USB ports for charging mobile devices.

4.2 Bagpanelfunktioner

  • Input strømledning: Connects the UPS to the wall outlet.
  • Batteribackup og overspændingsbeskyttede stikkontakter: Eight Schuko CEE 7/3 outlets that provide battery power during outagog overspændingsbeskyttelse.

5. Opsætning

5.1 Placering

Place the UPS in a location that meets the following conditions:

  • Away from direct sunlight, heat sources, and flammable materials.
  • On a flat, stable surface.
  • With adequate airflow around the unit.

5.2 Initial Battery Connection and Charging

  1. Sørg for, at UPS'en er slukket og frakoblet stikkontakten.
  2. Connect the internal battery. Refer to the battery compartment instructions if applicable (for this model, the battery is typically pre-connected and internal).
  3. Plug the UPS power cord directly into a grounded 230V wall outlet.
  4. Allow the UPS to charge for at least 24 hours before connecting any equipment to ensure full battery capacity. The unit will charge whether it is turned on or off.

5.3 Tilslutning af udstyr

Connect your electronic devices to the outlets on the UPS. All 8 Schuko outlets provide both battery backup and surge protection.

  • Batteribackup og overspændingsbeskyttede stikkontakter: Connect critical equipment such as computers, monitors, external hard drives, and network routers to these outlets. These devices will receive power from the UPS battery during an outage.
  • USB -opladningsporte: Use the two USB ports to charge compatible mobile devices.

6. Betjening af UPS'en

6.1 Tænd/sluk for UPS'en

  • At tænde: Press and hold the power button until you hear a short beep. The status indicators will illuminate.
  • At slukke: Press and hold the power button until you hear a long beep. The status indicators will turn off.

6.2 Statusindikatorer

The LEDs on the front panel provide information about the UPS status:

  • Online/On Battery: Indicates whether the UPS is operating on utility power or battery power.
  • Batteriopladningsniveau: Shows the approximate remaining battery capacity.
  • Overload/Fault: Warns of an overload condition or internal fault.

6.3 Automatisk Voltage Forordning (AVR)

UPS'en har automatisk spændingtage-regulering (AVR), som automatisk korrigerer mindre lydstyrkertage fluctuations (sags and surges) without using battery power. This extends battery life and protects connected equipment from unstable power conditions.

6.4 Runtime Expectations

The runtime provided by the UPS battery depends on the load connected. Higher loads result in shorter runtimes.

Diagram illustrating UPS runtime for different loads: 40W for 92 min, 119W for 28 min, 240W for 11 min.

Figur 6.1: Eksample runtimes for various loads. At half load, the UPS provides longer backup time compared to full load.

  • Entry-level Desktop (approx. 40W): Approximately 92 minutes of runtime.
  • Notebook (approx. 119W): Approximately 28 minutes of runtime.
  • Gaming PC (approx. 240W): Approximately 11 minutes of runtime.

7. Vedligeholdelse

7.1 Batteripleje og udskiftning

The UPS battery is a sealed lead-acid battery and typically lasts 3-5 years under normal operating conditions. Factors like frequent power outages and high temperatures can reduce battery life.

  • Udskiftning af batteri: When the battery needs replacement, the UPS will typically indicate this via an alarm or LED. Contact APC customer support for information on replacement batteries. Battery replacement should only be performed by qualified service personnel.
  • Bortskaffelse af batteri: Bortskaf brugte batterier i henhold til lokale regler.

7.2 Rengøring

To clean the exterior of the UPS, use a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure the UPS is turned off and unplugged before cleaning.

7.3 Opbevaring

If storing the UPS for an extended period, ensure the battery is fully charged. Recharge the battery every 3-6 months to prevent permanent damage and maintain battery health.

8. Fejlfinding

This section addresses common issues you might encounter with your UPS. If the problem persists after following these steps, contact APC customer support.

ProblemMulig årsagLøsning
UPS'en tænder ikkeBattery not connected or discharged; UPS not plugged in.Ensure battery is connected. Plug UPS into a wall outlet and allow to charge for 24 hours.
UPS'en bipper ofteOperating on battery power; Low battery; Overload.Check utility power. Allow battery to charge. Reduce connected load.
Tilsluttet udstyr mister strøm under en udgangtageEquipment connected to surge-only outlets (not applicable for this model as all are battery backup); Battery discharged or faulty.Ensure battery is fully charged. If issue persists, battery may need replacement.
UPS indicates an overloadFor mange enheder tilsluttet.Disconnect non-essential equipment to reduce the load.

9. Specifikationer

Detailed technical specifications for the APC Back-UPS BE1050G2-GR.

Dimension diagram of the APC Back-UPS BE1050G2-GR showing measurements in inches and millimeters.

Figure 9.1: Physical dimensions of the APC Back-UPS BE1050G2-GR.

FeatureDetalje
ModelnummerBE1050G2-GR
Kapacitet1050 VA
Input bindtage230 volt
Udgangsstik8 x Schuko CEE 7/3 (Battery Backup & Surge Protected)
USB-opladningsporte2 x 5V, 2.4A
Produktmål (D x B x H)14.37 x 5.12 x 4.72 tommer (365 x 130 x 120 mm)
Varens vægt8.8 pund (4 kg)
BatteritypeSealed Lead-Acid (Product Specific)
FarveSort

10. Garanti og support

APC provides a warranty for this product. The specific terms and duration of the warranty may vary by region. Please refer to the warranty card included with your product or visit the official APC webwebstedet for detaljerede garantioplysninger.

Image showing a person working at a desk with the UPS connected, alongside text about warranty details.

Figure 10.1: The APC Back-UPS provides peace of mind with its reliable power protection and warranty coverage.

For technical support, product registration, or to inquire about replacement parts, please visit the official APC by Schneider Electric website or contact their customer service department. Have your model number (BE1050G2-GR) and serial number ready when contacting support.

Beskyttelsesplaner: Additional protection plans may be available for purchase to extend coverage beyond the standard warranty. These plans typically offer extended service and support.

  • 2-årig beskyttelsesplan
  • 3-årig beskyttelsesplan
  • Komplet beskyttelse (månedligt abonnement)

11. Why You Need a Battery Backup UPS

An Uninterruptible Power Supply (UPS) like the APC Back-UPS BE1050G2-GR offers crucial benefits for protecting your electronics and ensuring continuity.

Infographic explaining the benefits of a battery backup UPS: uninterrupted Wi-Fi, protection from voltage fluctuations, and continuous device operation.

Figure 11.1: Key reasons to use a battery backup UPS.

  • Uninterrupted Connectivity: Maintain your network connection (Wi-Fi router, modem) during power outages, allowing you to stay online.
  • Protection from Voltage Udsving: Safeguard your sensitive electronics from damaging power surges, sags, and other irregularities.
  • Continuous Device Operation: Provide emergency power to critical devices, preventing data loss and ensuring essential equipment continues to run during power interruptions.

Relaterede dokumenter - BE1050G2-GR

Preview APC Back-UPS BX650LI-GR Brugervejledning: Sikkerhed, specifikationer og betjening
Omfattende brugervejledning til APC Back-UPS BX650LI-GR, der dækker sikkerhedsforanstaltninger, installation, funktioner, specifikationer, statusindikatorer, driftstilstande, fejlfinding og garantioplysninger.
Preview APC Back-UPS BR1200G-GR/BR1500G-GR: Installations- og betjeningsmanual
Brugervejledning til APC Back-UPS BR1200G-GR og BR1500G-GR modellerne. Dækker installation, opsætning, PowerChute-software, betjening, fejlfinding og tekniske specifikationer for pålidelig strømbeskyttelse.
Preview APC Back-UPS BR900G-GR Installations- og betjeningsmanual
Omfattende vejledning til installation, betjening og fejlfinding af APC Back-UPS BR900G-GR nødstrømsforsyningen. Indeholder sikkerhedsinstruktioner, opsætning, software og vedligeholdelsesoplysninger.
Preview APC Back-UPS BN600G Brugermanual
Brugermanual til APC Back-UPS BN600G Uninterruptible Power Supply (UPS), der indeholder sikkerhedsoplysninger, specifikationer, installation, betjening, fejlfinding og garantioplysninger.
Preview APC Back-UPS Pro 900 installations- og betjeningsvejledning
Denne vejledning indeholder instruktioner til installation og betjening af APC Back-UPS Pro 900, herunder opsætning, softwareinstallation, tilslutning af udstyr, driftsfunktioner som strømbesparelse og visningstilstande, fejlfinding og specifikationer.
Preview APC Back-UPS BR1000G-IN / BR1500G-IN: Installations- og betjeningsmanual
Omfattende vejledning til installation og betjening af APC Back-UPS BR1000G-IN og BR1500G-IN Uninterruptible Power Supply (UPS), der dækker specifikationer, tilslutninger, funktioner, fejlfinding og service.