ProCom ML200HBA-B

ProCom Heating Liquid Propane Ventless Blue Flame Heater

Model: ML200HBA-B (20,000 BTU, Manual Control)

Brugermanual

1. Vigtige sikkerhedsoplysninger

Please read and understand all instructions and warnings in this manual before installing, operating, or servicing this heater. Failure to follow these instructions may result in property damage, personal injury, or death.

2. Produktet er slutview

The ProCom Heating ML200HBA-B is a 20,000 BTU liquid propane ventless blue flame heater designed to provide reliable supplemental heat for areas up to 950 square feet. It features manual controls and a push-button piezo ignition system, requiring no electricity for operation.

ProCom Heating ML200HBA-B Ventless Blue Flame Heater

Figur 2.1: Forside view of the ProCom Heating ML200HBA-B Ventless Blue Flame Heater with base feet installed.

Nøglefunktioner:

Diagram illustrating key features of the ProCom heater: 20,000 BTU, No Venting Required, Works on Propane, No Electricity Required, Safe Clean Burning Heat, No Batteries or Matches Required, Piezo Ignition, Manual Controls.

Figure 2.2: Visual summary of the heater's operational features and benefits.

3. Opsætning og installation

This heater can be installed as a freestanding unit using the included base feet or permanently mounted to a wall using the provided wall bracket. Always ensure installation is performed by a qualified professional and adheres to all local codes and regulations.

3.1 Udpakning og inspektion

3.2 Beliggenhedskrav

ProCom heater installed on a wall in a living room setting.

Figur 3.1: Eksample of the heater installed on a wall, demonstrating its compact profile.

3.3 Attaching Base Feet (for Freestanding Use)

Close-up of the ProCom heater's blue flame and the included base feet.

Figure 3.2: Detail of the blue flame technology and the included base feet for stable placement.

3.4 Vægmontering (valgfrit)

3.5 Gastilslutning

4. Betjeningsvejledning

This heater features manual controls for ignition and heat output. No electrical power is required for basic operation.

4.1 Lighting the Heater (Piezo Ignition)

  1. Sørg for, at gasforsyningsventilen er åben.
  2. Locate the control knob and the ignitor button on the heater.
  3. Push in and turn the control knob counter-clockwise to the 'PILOT IGN' position.
  4. While holding the control knob in, repeatedly press the ignitor button until the pilot flame ignites. You should see a small blue flame at the pilot burner.
  5. Continue to hold the control knob in for approximately 30-60 seconds after the pilot flame ignites. This allows the thermocouple to heat up and hold the pilot valve open.
  6. Slip betjeningsknappen. Hvis pilotflammen slukker, gentag trin 3-5.
  7. Once the pilot flame is stable, push in and turn the control knob counter-clockwise to your desired heat setting (LOW, MEDIUM, or HIGH). The main burner will ignite.
Diagram showing the manual control knob with settings OFF, PILOT IGN, LOW, HIGH, and the separate ignitor button.

Figure 4.1: Manual control knob and ignitor button for operating the heater.

4.2 Justering af varmeafgivelse

To adjust the heat output, simply push in and turn the control knob to one of the three settings: LOW, MEDIUM, or HIGH. The heater will adjust its flame intensity accordingly.

4.3 Slukning af varmelegemet

To turn off the heater, push in and turn the control knob clockwise to the 'OFF' position. Ensure the main burner and pilot flame are extinguished. For extended periods of non-use, also close the main gas supply valve.

5. Vedligeholdelse

Regular maintenance ensures the safe and efficient operation of your heater. Always disconnect the gas supply and allow the heater to cool completely before performing any maintenance.

6. Fejlfinding

If you experience issues with your heater, consult the following troubleshooting guide. For problems not listed here or if solutions do not resolve the issue, contact a qualified service technician.

ProblemMulig årsagLøsning
Pilot vil ikke lyseIngen gasforsyning
Luft i gasledningen
Pilot orifice clogged
Tændingsapparatet gnister ikke
Ensure gas supply valve is open
Bleed air from line by holding pilot knob in for longer
Rengør pilotdysen
Check ignitor electrode for damage or proper gap
Pilot lights but will not stay lit when knob is releasedTermoelementet varmes ikke tilstrækkeligt op
Løs termoelementforbindelse
Defekt termoelement
Hold control knob in longer after pilot lights
Check and tighten thermocouple connection
Replace thermocouple (professional service recommended)
Hovedbrænderen tænder ikkePilot not lit
Main burner orifice clogged
Lavt gastryk
Ensure pilot is lit and stable
Rengør hovedbrænderåbningen
Verify adequate gas supply pressure
Heater produces an odorInitial burn-off of manufacturing oils
Dust/debris on burner
Utilstrækkelig ventilation
Operate heater in a well-ventilated area for a few hours
Clean burner area
Sørg for god ventilation i rummet
Varmeapparatet slukker uventetOxygen Depletion Sensor (ODS) activated
Lavt gastryk
Pilotflammen slukket
Increase ventilation in the room
Tjek gasforsyningen
Relight pilot flame

7. Specifikationer

Detailed technical specifications for the ProCom Heating ML200HBA-B heater.

Diagram showing the dimensions of the ProCom heater: 24 inches high, 19 inches long, 8 inches deep.

Figure 7.1: Product dimensions of the ProCom Heating ML200HBA-B heater.

FeatureSpecifikation
MærkeProCom
ModelnummerML200HBA-B
BrændstoftypeFlydende propan
Varmeoutput20,000 BTU/time
VarmedækningOp til 950 sq. ft.
KontroltypeManual (Low/Medium/High)
TændingstypePush-button Piezo
SikkerhedsfunktionerOxygen Depletion Sensor (ODS) with automatic shut-off
StrømkildeIngen elektricitet påkrævet
MonteringsmulighederFloor Stand (with included feet), Wall Mount (with included bracket)
Produktmål (L x B x H)19 cm x 9 cm x 24 cm
Varens vægt23.1 pund
UPC848660008413

8. Garanti og support

For warranty information, technical support, or to inquire about replacement parts, please contact ProCom Heating customer service. Keep your purchase receipt and model number readily available when contacting support.

Kontaktoplysninger kan typisk findes på producentens webwebstedet eller på produktemballagen.

Relaterede dokumenter - ML200HBA-B

Preview Procom NY PRO-9900 AM/FM Citizens Band 2-vejs radio brugermanual
Brugermanual til Procom NEW PRO-9900 AM/FM Citizens Band 2-vejs radio, der beskriver dens funktioner, betjening, egenskaber og tekniske specifikationer for optimal brug.
Preview PROCOM Atlas Loud Mouth Digital Trådløs Intercom Brugermanual
Denne brugermanual indeholder omfattende oplysninger om PROCOM Atlas Loud Mouth Digital Wireless Intercom, herunder dens funktioner, betjening, specifikationer, sikkerhedsretningslinjer og FCC-overholdelse.
Preview ProCom Heating Vent-Free Gas Space Heater: Operation and Installation Manual
Comprehensive guide for ProCom Heating vent-free gas space heaters, covering installation, operation, safety, maintenance, and troubleshooting for models MN180TPA-B, ML150TPA-B, MN300TPA-B, and ML250TPA-B.
Preview Bauer 30K-60K BTU Tvungen Luft Propan Bærbar Varmeapparat Brugermanual og Sikkerhedsinstruktioner
Denne brugermanual indeholder vigtige sikkerhedsadvarsler, betjeningsvejledninger, vedligeholdelsesretningslinjer og specifikationer for Bauer 30K-60K BTU transportabel propanvarmer med tvangsluft (model 19161P-B). Den dækker opsætning, betjening og sikkerhedsforanstaltninger til brug i byggeri.
Preview Bauer 30K-60K BTU Tvungen Luft Propan Bærbar Varmeapparat Brugermanual og Sikkerhedsinstruktioner
Omfattende brugermanual og sikkerhedsinstruktioner til Bauer 30K-60K BTU transportabel propanvarmer med tvangsluft (vare 57176). Dækker opsætning, betjening, vedligeholdelse, sikkerhedsadvarsler og fejlfinding til brug i byggeri.
Preview L.B. White Premier Tent Heaters Owner's Manual and Instructions TS080 TS170
Comprehensive owner's manual and instructions for L.B. White Premier Tent Heaters (Models TS080, TS170), covering installation, operation, safety, and maintenance for temporary heating applications.