Produkt overview
The A-iPower 4600W RV-Ready Quiet Portable Inverter Generator is designed to provide reliable and clean power for various applications. It generates 4600 starting watts and 3600 running watts, suitable for RV appliances, home backup, and sensitive electronics. Its lightweight and open-frame design enhances portability, while the CO Sensor ensures user safety by automatically shutting down the unit in the presence of dangerous carbon monoxide levels.

Figur 1: Forside view of the A-iPower 4600W Inverter Generator, showcasing dens kompakte design og kontrolpanel.
Nøglefunktioner
- Kraftig ydeevne: Engine displacement 149 cubic centimeters. Generates 4600 starting watts and 3600 running watts, providing AC 120V/60Hz ample power for various RV appliances and equipment.
- Letvægts bærbarhed: Weighs only 56 lbs, making it easy to lift and transport by hand for convenient camping and off-grid use.
- Pure Power: 3% THD of clean power output. Inverter technology provides a clean stable source of power for sensitive electronics such as laptops, TVs, phone chargers, and sensitive power tools.
- RV-Ready Connectivity: Features 5 power outlets, including a TT-30R adapter, allowing direct connection to your RV for hassle-free power supply.
- Low Idle Technology + Extended Run Time: A 2.6-gallon fuel tank provides up to 16 hours of continuous operation at 25% load, minimizing the need for frequent refueling.

Figure 2: Visual representation of the generator's key features including parallel readiness, powerful engine, ultra-lightweight design, and clean energy output.
Sikkerhedsretningslinjer
Always operate the generator in a well-ventilated outdoor area, away from windows, doors, and vents to prevent carbon monoxide buildup. Never operate indoors or in enclosed spaces.
- CO-sensor: The integrated CO Sensor automatically shuts down the generator if dangerous levels of carbon monoxide are detected. Do not disable or tampmed denne sikkerhedsfunktion.
- Brændstofhåndtering: Always refuel in a well-ventilated area with the engine off and cooled. Avoid spilling fuel.
- Jording: Ensure the generator is properly grounded before operation to prevent electrical shock.

Figure 3: Close-up of the generator's control panel highlighting the CO Sensor, a critical safety feature.
Indledende opsætning
Før første brug skal du sørge for, at generatoren er placeret på en plan overflade, og følge disse trin:
- Tilsæt motorolie: Remove the oil fill cap/dipstick. Using the provided funnel, carefully add 0.42 quarts (0.4 L) of SAE 10W-30 engine oil. Do not overfill. Check the oil level with the dipstick.
- Tilføj brændstof: Ensure the fuel cap is securely fastened. Use fresh, unleaded gasoline with a minimum octane rating of 87. The fuel tank capacity is 2.6 gallons. Do not store fuel in the tank for extended periods.
- Tjek luftfilter: Sørg for, at luftfilteret er rent og korrekt installeret.

Figure 4: The generator shown with its included accessories, such as the oil bottle, funnel, and RV adapter, essential for initial setup.
Operation
Kontrolpanel overview

Figur 5: Detaljeret view of the generator's control panel, indicating the location of various switches and outlets.
- CO-sensor: Safety indicator and automatic shutdown.
- Motorafbryder: ON/OFF switch for the engine.
- Low Idle Switch (Eco Mode): Engages fuel-saving and noise-reducing mode.
- Nulstil switch: For resetting circuit breakers.
- Parallel Equipped: Outlets for connecting two identical generators for increased power output.
- USB-A / USB-C AC Outlet: Til opladning af små elektroniske enheder.
- 5-20R Duplex 20A, 120V AC Outlets: Standard stikkontakter i husholdningen.
- L5-30R 30A, 120V AC Outlet: RV-ready outlet.
Start af generatoren
- Sørg for, at generatoren står på en plan overflade, og at alle forbindelser er sikre.
- Drej brændstofventilen til positionen ON.
- Move the choke lever to the FULL CHOKE position (if cold starting).
- Flip the Engine Switch to the ON position.
- Træk fast i håndtaget til rekylstarteren, indtil motoren starter.
- Once the engine starts, gradually move the choke lever to the RUN position.
Tilslutning af enheder
Once the generator is running smoothly, you can connect your electrical devices. The inverter technology provides clean power (less than 3% THD), making it safe for sensitive electronics.
- RV Connection: Use the provided TT-30R adapter to connect directly to your RV's power inlet.
- Standard Appliances: Plug 120V devices into the 5-20R duplex outlets.
- USB-enheder: Use the USB-A or USB-C ports for charging phones, tablets, etc.

Figure 6: The generator providing power to an RV, demonstrating its RV-ready capabilities.
Eco Mode (Low Idle Technology)
Engage the Low Idle Switch (Eco Mode) when running light loads to reduce engine speed, conserve fuel, and minimize noise output. The engine will automatically adjust its speed based on the connected load.
Stop af generatoren
- Afbryd alle elektriske belastninger fra generatoren.
- If Eco Mode is engaged, switch it OFF.
- Flip the Engine Switch to the OFF position.
- Drej brændstofventilen til OFF-positionen.
Opretholdelse
Regular maintenance is crucial for the longevity and optimal performance of your generator. Always refer to the full owner's manual for detailed instructions.
- Olieskift: Change the engine oil after the first 20 hours of operation. Subsequently, change the oil every 100 hours or annually, whichever comes first.
- Luftfilter: Inspicer og rengør luftfilteret hver 50. time eller oftere i støvede forhold. Udskift det, hvis det er beskadiget.
- Tændrør: Undersøg tændrøret hver 100 timer. Rengør eller udskift efter behov.
- Brændstofsystem: For long-term storage, drain the fuel tank and carburetor to prevent fuel degradation.

Figure 7: The generator's engine enclosure, providing access to components for routine maintenance.
Fejlfinding Guide
If your generator experiences issues, consult the table below for common problems and solutions. For complex issues, contact customer support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Motoren vil ikke starte | No fuel, low oil, engine switch OFF, choke incorrect, fouled spark plug. | Add fuel, add oil, turn engine switch ON, adjust choke, clean/replace spark plug. |
| Ingen strømudgang | Overload, circuit breaker tripped. | Reduce load, press reset button on control panel. |
| Low oil alert light ON | Lavt motorolieniveau. | Tilsæt motorolie til det korrekte niveau. |
| CO-sensor aktiveret | Carbon monoxide detected. | Move generator to a well-ventilated outdoor area. |
Tekniske specifikationer
| Specifikation | Værdi |
|---|---|
| Mærke | A-iPower |
| Modelnavn | SUA4600IF |
| Starter Wattage | 4600 watt |
| Løb Wattage | 3600 watt |
| Brændstoftype | Benzin |
| Strømkilde | Brændstofdrevet |
| Varens vægt | 56 pund |
| Voltage | 120 volt |
| Motortype | 4 takt |
| Motorens slagvolumen | 149 kubikcentimeter |
| Tankvolumen | 2.6 gallons |
| Samlet strømudtag | 5 |
| Produktdimensioner | 18.9 cm L x 13.4 cm B x 17.5 cm H |
| Særlige funktioner | Automatic Shut Down, CO Sensor, Lightweight, Low Oil Shutdown, USB Port |

Figure 8: The generator with its key dimensions (length, width, height) and weight indicated.
Officiel produktvideo
Video 1: En overview of the A-iPower 4600W Inverter Generator, highlighting its features and operation. Provided by A-iPower Corp.
Garanti og kundesupport
A-iPower offers various protection plans for your generator. For detailed warranty information and terms, please refer to the official A-iPower webwebstedet eller garantikortet, der følger med dit produkt.
- 4-årig beskyttelsesplan: Tilgængelig for udvidet dækning.
- Fuld beskyttelse: En månedlig plan, der dækker berettigede tidligere og fremtidige køb.
For customer support, please contact the manufacturer directly. Contact information can typically be found in your product manual or on the A-iPower webwebsted.