ACiQ ACiQ-48-AC

ACiQ 4 Ton 15.5 SEER2 Central Airconditionsystem Brugermanual

Model: ACiQ-48-AC / ACIQ-60-ACL / IKIC51

1. Introduktion

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

2. Sikkerhedsoplysninger

Vigtige sikkerhedsinstruktioner:

3. Produktet er slutview og funktioner

The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.

Nøglefunktioner:

Inkluderede komponenter:

The complete system includes the following components:

ACiQ 4 Ton Central Air Conditioner System components

Figur 3.1: Overview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

ACiQ Split System Installation Kit components

Figur 3.2: Detaljeret view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

ACiQ Air Conditioner Condenser Unit Features

Figur 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.

4. Opsætning og installation

Professionel installation påkrævet: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.

The installation process typically involves:

  1. Valg af websted: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
  2. Mounting Units: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
  3. Tilslutning af kølemiddelledning: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
  4. Elektriske ledninger: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
  5. Kondensatafløb: Installing proper drainage for the indoor evaporator coil.
  6. Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
  7. Termostat installation: Wiring and configuring the Smart WiFi Thermostat.
  8. Systemtest: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.

Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.

5. Betjeningsvejledning

Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.

Smart WiFi Thermostat Operation:

The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:

Smart WiFi Thermostat features and interface

Figur 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.

For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.

6. Vedligeholdelse

Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.

Brugervedligeholdelse (månedligt/kvartalsvis):

Professionel vedligeholdelse (årligt):

It is highly recommended to schedule annual maintenance with a qualified HVAC technician. This typically includes:

7. Fejlfinding

Inden du kontakter en servicetekniker, vedrview the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.

ProblemMulig årsagLøsning
System Not Cooling
  • Termostat indstillet forkert
  • Beskidt luftfilter
  • Outdoor unit obstructed
  • Problem med strømforsyning
  • Refrigerant leak (system alert)
  • Check thermostat settings (mode, temperature).
  • Rengør eller udskift luftfilteret.
  • Clear debris from outdoor unit.
  • Check circuit breaker; ensure disconnect switch is ON.
  • Kontakt en kvalificeret tekniker for inspektion og reparation.
Svag luftstrøm
  • Beskidt luftfilter
  • Blocked return air vents
  • Problemer med kanalføring
  • Rengør eller udskift luftfilteret.
  • Ensure all return air vents are open and unobstructed.
  • Consult a technician to inspect ductwork.
Usædvanlige lyde
  • Løse dele
  • Affald i ventilator
  • Motorproblemer
  • Turn off unit and inspect for loose panels or debris.
  • If noise persists or is severe, contact a technician.
Water Leakage (Indoor Unit)
  • Tilstoppet kondensatafløbsledning
  • Frozen evaporator coil
  • Rens kondensafløbsledningen.
  • Turn off cooling and allow coil to defrost; check airflow and refrigerant levels. Contact technician if problem persists.

If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.

8. Specifikationer

Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:

SpecifikationVærdi
MærkeACiQ
ModelnumreACiQ-48-AC / ACIQ-60-ACL / IKIC51
Kapacitet4 tons (48,000 BTU/t)
Effektivitet (SEER2)15.5 SEER2
KølevæsketypeR410A
Voltage230 volt
Wattage4000 watt
Støjniveau56 dB
Udendørsenheds dimensioner (D x B x H)16.14 cm x 37.24 cm x 52.48 cm
Indoor Coil Dimensions (W x D x H)622 x 533 x 711 mm (24.49" x 20.98" x 27.99")
InstallationstypeOpdelt system
FormfaktorCentral Split System
FiltertypeWashable, Reusable Mesh Filter
Dækning af gulvarealCirka 2400 kvadratmeter
Særlige funktionerInverter Unit, Smart Sensors, Gold Fin Coil, Ultra-Quiet, All-Climate Performance
Dimensions of ACiQ outdoor condenser and indoor evaporator coil

Figur 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Specifications for ACiQ evaporator coil

Figur 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

AHRI Rating Conditions and EnergyGuide label for ACiQ system

Figur 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.

9. Garanti og support

Garantibetingelser: ACiQ-systemet leveres med en 7 års reservedelsgaranti og en 12 års kompressorgaranti. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.

Kundesupport: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official webwebstedet eller den dokumentation, der fulgte med dit køb. Du kan også besøge ACiQ Store on Amazon for mere information.

Relaterede dokumenter - ACiQ-48-AC

Preview Installationsmanual til ACiQ Central Inverter Systems udendørsenhed
Omfattende installationsmanual til ACiQ Central Inverter Systems udendørsenheder, der dækker sikkerhedsforanstaltninger, kølemiddelrør, installation af udendørsenhed, ledningsføring, strømspecifikationer, luftevakuering og testkørselsprocedurer. Indeholder modeloplysninger og vigtige noter til korrekt opsætning.
Preview Installationsmanual til ACiQ centrale invertersystemer
Omfattende installationsmanual til ACiQ centrale inverter klimaanlæg og varmepumpesystemer, med detaljerede oplysninger om sikkerhedsforanstaltninger, kølemiddelrør, installation af udendørsenhed, ledningsføring, strømspecifikationer, luftevakuering og testkørselsprocedurer.
Preview Installationsmanual til ACiQ Central Inverter Systems udendørsenhed
Omfattende installationsmanual til ACiQ Central Inverter Systems udendørsenheder, der dækker sikkerhedsforanstaltninger, kølemiddelrør, ledningsføring, enhedsinstallation og testprocedurer for modeller som ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB og andre.
Preview ACiQ R32 Unitary Air Handler & Heat Pump Condenser Technical Sales Guide
This technical sales guide provides detailed specifications, performance data, dimensions, and wiring diagrams for the ACiQ R32 Unitary Air Handler and Heat Pump Condenser series, covering models ACiQ-24/36/48/60-AH32 and ACiQ-24/36/48/60-HP32.
Preview Installationsmanual til ACiQ-kanalluftbehandler (12-60 BTU/t)
Denne installationsmanual fra ACiQ indeholder detaljerede instruktioner til sikker og korrekt installation af kanallufthåndteringsenheder, modeller 12K til 60K BTU/t. Den dækker vigtige sikkerhedsretningslinjer, placering af enheder, kølemiddelrør, elektriske ledninger, specifikationer og driftstest for at sikre optimal ydeevne og systemets levetid.
Preview ACiQ Next Gen kanalvarmepumpesystem hurtigstartguide
Lynstartguide til ACiQ Next Gen kanalvarmepumpesystem, der dækker ledningsdiagrammer, termostattilslutninger og DIP-switchindstillinger til forskellige installationsscenarier.