1. Introduktion

The INKBIRDPLUS Plug-in Temperature Controller is a versatile and intelligent device designed to precisely manage temperature for a wide range of applications. It supports both heating and cooling modes, offering four flexible timing functions and a clear backlit LCD for easy operation. This manual provides detailed instructions for setup, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your device.

2. Produktet er slutview

Labeled diagram of the INKBIRDPLUS temperature controller components

Figur 2.1: Labeled diagram of the INKBIRDPLUS temperature controller, showing its various parts including the measured temperature display, start and stop temperature settings, indicator light, power outlet, mode switch, control buttons, and the external temperature probe.

Komponenter:

3. Nøglefunktioner

Diagram showing key features of the INKBIRDPLUS temperature controller

Figur 3.1: Overview of the INKBIRDPLUS temperature controller's main features, including heating/cooling, periodic timing, backup memory, temperature calibration, and a backlit LCD screen.

4. Specifikationer

Diagram showing the dimensions of the INKBIRDPLUS temperature controller

Figur 4.1: Physical dimensions of the INKBIRDPLUS temperature controller and its temperature probe.

SpecifikationVærdi
MærkeINKBIRDPLUS
ModelnavnINK+TC8
Produktdimensioner3.5 cm D x 6.7 cm B x 12.5 cm H (1.38 cm D x 2.64 cm B x 4.92 cm H)
Controller typeHåndkontrol
Speciel funktionTemperaturvisning, Programmerbar
FarveTc+cd
Specifikke anvendelser af produktetElectric Baseboard Heater, Air Conditioner, Refrigerator, Reptile, Incubation, Aquarium, Home Brewing
Temperaturkontrol typeKøling & Opvarmning
Inkluderede komponenterController with integrated temperature probe
Varens vægt0.34 pund (5.4 ounce)
Voltage120 volt
MaterialePlast
FormFirkant
KontrolmetodeKnap kontrol
MonteringstypeVægmontering (tilslutning)
Temperaturområde-40 ℃ til 120 ℃ (-40 ℉ til 248 ℉)
Max belastning15A 1800W
Temperaturkontrol nøjagtighed±1 ℃/℉
Timing nøjagtighedMax 10 minutter
Probe beskyttelseIP67 vandtæt

5. Opsætning

  1. Pak enheden ud: Carefully remove the temperature controller and its probe from the packaging.
  2. Tilslut: Insert the temperature controller into a standard 120V AC power outlet. The LCD screen will illuminate.
  3. Position the Probe: Place the temperature probe in the environment where you wish to measure and control the temperature. Ensure the probe is securely positioned and not directly exposed to heat sources or drafts that could skew readings. The IP67 rating allows for use in wet environments like aquariums.
  4. Tilslut din enhed: Plug your heating or cooling appliance (e.g., heater, fan, refrigerator) into the power outlet on the front of the temperature controller.

6. Betjeningsvejledning

6.1 Basic Temperature Control (Heating/Cooling Modes)

Image illustrating heating and cooling control with temperature range

Figur 6.1: The controller's ability to manage both heating and cooling, with its wide temperature range.

  1. Tænd: Ensure the controller is plugged in and the LCD is active.
  2. Set Start Temperature:
    • Tryk på SÆT button once. The 'Start Temperature' value will begin to flash.
    • Brug UP or NED buttons to adjust the desired start temperature.
    • Trykke SÆT again to confirm and move to the Stop Temperature setting.
  3. Set Stop Temperature:
    • The 'Stop Temperature' value will flash.
    • Brug UP or NED buttons to adjust the desired stop temperature.
    • Trykke SÆT again to confirm and exit the temperature setting mode.
  4. Select Mode (Heating/Cooling):
    • The controller automatically determines heating or cooling mode based on your Start and Stop temperature settings.
    • If Start Temp < Stop Temp: The controller operates in Opvarmningstilstand. The connected device will turn ON when the measured temperature drops below the Start Temp and turn OFF when it reaches the Stop Temp.
    • If Start Temp > Stop Temp: The controller operates in Køletilstand. The connected device will turn ON when the measured temperature rises above the Start Temp and turn OFF when it reaches the Stop Temp.

6.2 Flexible Timing Modes

The INKBIRDPLUS controller offers four advanced timing modes for precise control over your connected devices. These modes are accessed by pressing the Mode switch knappen (husikon).

Diagram explaining the four flexible timing functions

Figur 6.2: Visual guide to the four timing modes: CD TC ON, CD TC OFF, CD ON Timer, and CD OFF Timer.

  1. CD TC ON Mode (Countdown Temperature Control ON):
    • In this mode, the device will operate according to the set temperature control (TC) mode (heating or cooling) efter a specified countdown timer ends.
    • Use Case: You want a device to start maintaining a specific temperature only after a certain delay (e.g., start heating a terrarium 30 minutes after lights turn on).
    • For at indstille: Tryk Mode switch until "CD TC ON" appears. Press SÆT, og brug derefter OP/NED to set the countdown time (Hours:Minutes). Press SÆT for at bekræfte.
    Diagram for CD TC ON timing mode setting

    Figur 6.3: Setting the countdown time for CD TC ON mode.

  2. CD TC OFF Mode (Countdown Temperature Control OFF):
    • In this mode, the device will operate according to the set temperature control (TC) mode (heating or cooling) indtil a specified countdown timer ends. Once the countdown finishes, the temperature control function will stop.
    • Use Case: You want to maintain a specific temperature for a set duration, then turn off the control (e.g., maintain incubation temperature for 24 hours, then stop).
    • For at indstille: Tryk Mode switch until "CD TC OFF" appears. Press SÆT, og brug derefter OP/NED to set the countdown time (Hours:Minutes). Press SÆT for at bekræfte.
    Diagram for CD TC OFF timing mode setting

    Figur 6.4: Setting the countdown time for CD TC OFF mode.

  3. CD ON Timer (Countdown ON Timer):
    • In this mode, the connected device will turn ON efter a specified countdown timer ends, regardless of temperature.
    • Use Case: You want a device to simply turn on after a delay (e.g., turn on a fan after 1 hour).
    • For at indstille: Tryk Mode switch until "CD ON" appears. Press SÆT, og brug derefter OP/NED to set the countdown time (Hours:Minutes). Press SÆT for at bekræfte.
  4. CD OFF Timer (Countdown OFF Timer):
    • In this mode, the connected device will turn OFF efter a specified countdown timer ends, regardless of temperature.
    • Use Case: You want a device to simply turn off after a delay (e.g., turn off a light after 30 minutes).
    • For at indstille: Tryk Mode switch until "CD OFF" appears. Press SÆT, og brug derefter OP/NED to set the countdown time (Hours:Minutes). Press SÆT for at bekræfte.

6.3 Temperaturkalibrering

Image demonstrating the temperature calibration function

Figur 6.5: The temperature calibration feature allows for fine-tuning the temperature reading.

If you find that the temperature displayed by the controller does not match a known accurate thermometer, you can calibrate it. This function allows you to adjust the measured temperature reading by a certain offset (±9 ℃/℉).

  1. Gå ind i kalibreringstilstand: With the device in normal operating mode, press and hold the SÆT button for approximately 3 seconds until the display changes to show a calibration value (e.g., "0.0").
  2. Adjust Calibration Value: Brug UP or NED buttons to adjust the offset. Increase the value if the controller reads lower than actual, decrease if it reads higher.
  3. Bekræft indstilling: Tryk på SÆT button again to save the calibration and exit the mode. The controller will now display the adjusted temperature.

6.4 Backlight Control

Image showing the backlit LCD screen in a room setting

Figur 6.6: The backlit LCD screen provides clear visibility in various lighting conditions.

To conserve power or for use in dark environments, you can toggle the backlight. Simply press the NED button briefly to turn the backlight ON or OFF.

6.5 Hukommelsesfunktion

The INKBIRDPLUS controller features a built-in memory system. In the event of a power outage, all your previously set parameters (start/stop temperatures, timing modes, calibration) are automatically saved. When power is restored, the device will resume operation with your last settings, ensuring continuous and reliable control without the need for manual reprogramming.

7. Ansøgninger

Collage of various applications for the temperature controller

Figur 7.1: The INKBIRDPLUS temperature controller is suitable for a wide range of applications, including home brewing, incubation, refrigeration, home climate control, reptile habitats, aquariums, and even e-bike charging.

This temperature controller is highly versatile and can be integrated into numerous scenarios requiring precise temperature management:

8. Vedligeholdelse

9. Fejlfinding

ProblemMulig årsag og løsning
Skærmen er tom eller tænder ikke.
  • Ingen kraft: Ensure the controller is securely plugged into a live power outlet. Test the outlet with another device.
  • Power outage: Tjek din boligs strømforsyning.
Temperaturaflæsningen er unøjagtig.
  • Probe misplacement: Ensure the probe is correctly positioned in the environment you wish to measure, away from direct heat/cold sources or drafts.
  • Calibration needed: Use the Temperature Calibration function (Section 6.3) to adjust the reading if you have a known accurate reference thermometer.
  • Damaged probe: Inspect the probe and cable for any visible damage. If damaged, contact support for replacement.
Connected device not turning ON/OFF as expected.
  • Incorrect Start/Stop Temp settings: Review your set temperatures (Section 6.1) to ensure they align with your desired heating or cooling operation. Remember: Start < Stop for Heating, Start > Stop for Cooling.
  • Incorrect Timing Mode: If a timing mode is active, it might override temperature control. Check the active timing mode (Section 6.2) and ensure it's set correctly or disabled if not needed.
  • Enhedsfejl: Test the connected heating/cooling device by plugging it directly into a wall outlet to ensure it is functional.
  • Overbelaste: Ensure the connected device's power consumption does not exceed the controller's maximum load (15A 1800W).
Baggrundslyset er slukket.
  • Backlight toggled off: Tryk på NED button to toggle the backlight ON (Section 6.4).

10. Garanti og support

For warranty information, technical support, or service inquiries, please refer to the product packaging or contact INKBIRDPLUS customer service directly through their official website or the platform where the product was purchased. Please have your model number (INK+TC819-US) and purchase details ready when contacting support.

Relaterede dokumenter - INK+TC819-US

Preview INKBIRDPLUS T01 Prize Termostat Minuterie Manuel de l'Utilisateur
Manuel d'utilisation pour la prize termostat minutie INKBIRDPLUS T01. Guide komplet over les fonctions af kontrol af temperatur og minutie, les modes de fonctionnement, le calibrage og les specifikation teknikker.
Preview INKBIRDPLUS PTH-9A Multifunktionsluftkvalitetsdetektor Brugermanual
Omfattende brugermanual til INKBIRDPLUS PTH-9A multifunktionsluftkvalitetsdetektor, der dækker produktintroduktion, specifikationer, betjeningsvejledning, indstilling af tid/dato og garantioplysninger. Overvåger PM2.5, PM10, CO2, temperatur og luftfugtighed.
Preview INKBIRDPLUS HS-16 metaldetektor brugermanual og brugervejledning
Detaljeret brugermanual til INKBIRDPLUS HS-16 metaldetektoren, en vandtæt håndholdt enhed med LCD-skærm. Dækker funktioner, specifikationer, betjening og batteriudskiftning for effektiv metaldetektion.