AUTOOL LM160

AUTOOL LM160 Smart Digital Manifold Kit Brugermanual

Model: LM160 | Brand: AUTOOL

1. Produktet er slutview

The AUTOOL LM160 AC Manifold Gauge Set is a comprehensive digital tool designed for accurate measurement of temperature, pressure, and vacuum in refrigerant systems. It supports 95 types of refrigerants and offers various operational modes including evacuation, refrigeration, and pressure leak testing. This kit is suitable for a wide range of applications, from automotive to industrial refrigeration systems.

AUTOOL LM160 Digital Manifold Gauge Set with accessories

Image: The AUTOOL LM160 digital manifold gauge set, including the main unit, pipe clamp thermometers, refrigerant hoses, and a carrying case.

2. Hvad er der i æsken

Your AUTOOL LM160 package includes the following components:

Components of the AUTOOL LM160 kit

Image: All components of the AUTOOL LM160 kit laid out, including the digital gauge, hoses, temperature clamps, and carrying case.

3. Opsætning og forbindelser

Before operating the AUTOOL LM160, ensure all connections are secure and correct.

  1. Tilslut temperaturprober: Insert the two pipe clamp thermometer probes into the designated ports on the top of the digital manifold unit. Securely attach the clamps to the refrigerant lines (e.g., suction and liquid lines) to measure pipe temperatures.
  2. Tilslutning af kølemiddel slanger:
    • Connect the blue hose to the low-pressure (LP) side of the system and the blue port on the manifold.
    • Connect the red hose to the high-pressure (HP) side of the system and the red port on the manifold.
    • Connect the yellow hose to the service port (e.g., vacuum pump or refrigerant tank) and the central port on the manifold.
  3. Tænd: Press the power button to turn on the digital manifold gauge.

Video: This video demonstrates the connection of the clamp temperature probes and refrigerant lines to the AUTOOL LM160 digital manifold gauge, showing the initial setup process for AC system diagnostics.

4. Driftstilstande

The AUTOOL LM160 offers three primary operating modes for comprehensive AC system analysis.

4.1. Vacuuming Mode

This mode is used to remove external gases and moisture from the refrigeration circuit, ensuring a clean system before refrigerant charging.

  1. Tilslut den gule slange til en vakuumpumpe.
  2. Select "Evacuation" mode on the LM160.
  3. Open the low-pressure valve on the manifold.
  4. Activate the vacuum pump. The screen will display evacuation time, current pressure, water evaporation temperature, ambient temperature, and temperature difference.
  5. Monitor the vacuum level until the desired vacuum is achieved.
AUTOOL LM160 Vacuuming Mode screen

Image: The AUTOOL LM160 display showing the "Evacuation" mode interface, with real-time data for hold time, current pressure, water evaporation temperature, ambient temperature, and temperature difference.

4.2. Refrigeration Mode

In this mode, the gauge measures the pressure and temperature of the refrigeration system in real-time, allowing for accurate charging and performance assessment.

  1. Ensure the system is properly evacuated.
  2. Tilslut den gule slange til kølemiddeltanken.
  3. Select the desired refrigerant type from the built-in database (supports 95 refrigerants).
  4. Turn on the AC system of the vehicle/equipment.
  5. Open the LP and HP valves on the manifold to allow refrigerant flow.
  6. Monitor the LP (low pressure), HP (high pressure), Ev (evaporation temperature), Co (condensation temperature), T1 (evaporation temp. of measured pipe), T2 (condensation temp. of measured pipe), SH (superheating evaporation temp.), and SC (subcooling condensation temp.) readings on the display. The sight glass allows direct observation of refrigerant charge flow.
AUTOOL LM160 Refrigeration Mode screen

Image: The AUTOOL LM160 display showing the "Refrigeration" mode interface, providing real-time pressure and temperature data for various points in the AC system.

List of 95 supported refrigerants

Image: A comprehensive list of 95 refrigerants supported by the AUTOOL LM160, including common types like R134a, R22, R410A, and R1234yf.

4.3. Leakage Detection

This function helps determine if refrigerant is leaking by calculating the pressure difference over time.

  1. Ensure the system is charged to the appropriate pressure.
  2. Select "Pressure Leak Test" mode on the LM160.
  3. The device will record an initial pressure ("Start P").
  4. Monitor the "Current P" and "Delta P" (pressure difference) over a set period. A significant "Delta P" indicates a leak.
AUTOOL LM160 Pressure Leak Test screen

Image: The AUTOOL LM160 display showing the "Pressure Leak Test" mode interface, displaying start pressure, current pressure, and the calculated pressure difference over time.

5. Nøglefunktioner og -funktioner

AUTOOL LM160 Multiple Units and Pressure Ranges

Image: The AUTOOL LM160 display showing the various units and pressure ranges supported for temperature, vacuum, and pressure measurements.

AUTOOL LM160 Design Features

Billede: Nærbillede views highlighting the 2.8-inch backlit display, silicone handles, foldable hook, and refrigerant visible window of the AUTOOL LM160.

AUTOOL LM160 Multi-language Support

Image: The AUTOOL LM160 display showing the language selection menu, indicating support for English, French, Italian, Spanish, German, Portuguese, Chinese, and Japanese.

6. Specifikationer

ParameterVærdi
Produktdimensioner15 x 13 x 5 tommer
Varens vægt9 pund
ModelnummerLM160
MærkeAUTOOL
MaterialeGlass (for sight glass)
Pressure Measurement Unitspsi / kPa / MPa / bar / kg/cm²
Vacuum Measurement UnitsMicron / hPa / mbar / mTorr / Torr
Temperaturenheder° F / ° C
Number of Supported Refrigerants95
ViseBaggrundsbelyst display

7. Vedligeholdelse

Proper maintenance ensures the longevity and accuracy of your AUTOOL LM160 Digital Manifold Kit.

8. Fejlfinding

If you encounter issues with your AUTOOL LM160, refer to the following common troubleshooting steps:

ProblemMulig årsagLøsning
Enheden tænder ikkeLow or dead batteries; power button issue.Replace batteries. Ensure power button is pressed firmly.
Unøjagtige aflæsningerLoose connections; sensor malfunction; need for calibration.Check all hose and probe connections. Ensure probes are clean and properly attached. Consider professional calibration if issues persist.
Skærmen er frossen eller reagerer ikkeSoftwarefejl; lavt batteri.Restart the unit. Replace batteries. If problem persists, contact customer support.
"Delta P" in leak test is highRefrigerant leak in the system or connections.Inspect all connections, hoses, and system components for leaks. Use a leak detector if necessary.

For yderligere assistance henvises til kontaktoplysningerne i afsnittet Garanti og support.

9. Garanti og support

AUTOOL provides a three-year warranty for the LM160 AC Manifold Gauge Set. If the product has any defect, AUTOOL will provide a new replacement or solutions to ensure customer satisfaction without delay. Lifetime technical support is also provided.

For any needs or technical assistance, you are warmly welcomed to contact AUTOOL customer support. They aim to respond within 24 hours.

Kontaktoplysninger: Please refer to the contact details provided in your product packaging or visit the official AUTOOL webwebstedet for de mest opdaterede supportoplysninger.

Relaterede dokumenter - LM160

Preview AUTOOL LM160 Smart Digital Manifold Kit Brugermanual
Denne brugermanual indeholder omfattende instruktioner til AUTOOL LM160 Smart Digital Manifold Kit, der dækker sikkerhedsregler, produktbeskrivelse, tekniske specifikationer, drift, vedligeholdelse og garantioplysninger. Den beskriver enhedens funktioner og parametre, herunder tryk- og temperaturmålinger, vakuumkapacitet og kompatibilitet med forskellige kølemidler.
Preview AUTOOL LM160 Smart Digital Manifold Kit Brugermanual
Omfattende brugermanual til AUTOOL LM160 Smart Digital Manifold Kit, der dækker betjening, tekniske specifikationer, vedligeholdelse og sikkerhed for HVAC-applikationer.
Preview AUTOOL LM120+ digital manifoldmåler brugermanual
Omfattende brugermanual til AUTOOL LM120+ digital manifoldmåler, med detaljerede oplysninger om funktioner, specifikationer, sikkerhedsforanstaltninger, betjeningsvejledning og fejlfindingstips til køle- og HVAC-systemer.
Preview AUTOOL LM110 Digital Manifoldmåler Brugermanual
Brugermanual til AUTOOL LM110 digital manifoldmåler, der indeholder detaljerede instruktioner om dens funktioner, betjening, specifikationer og fejlfinding til vedligeholdelse af kølesystemet.
Preview AUTOOL LM150 Digital Manifold Trykmåler Brugermanual - HVAC Kølemiddelværktøj
Omfattende brugermanual til AUTOOL LM150 digital manifoldtryksmåler. Dækker produktspecifikationer, betjeningsvejledning til kølemiddelpåfyldning, vakuum- og lækagetest, almindelige problemer, ordliste, vedligeholdelse, garanti og returpolitik for HVAC- og kølefagfolk.
Preview AUTOOL LM120/LM120+ Digital Manifoldmåler Brugermanual
Denne brugermanual giver omfattende vejledning til AUTOOL LM120/LM120+ digital manifoldmåler. Den beskriver produktspecifikationer, struktur, funktionsinstruktioner til kølemiddelpåfyldning, vakuumdrift og tryklækagetest. Manualen indeholder også almindelige problemer, en ordliste, vedligeholdelsesråd, garantioplysninger og retur-/ombytningsprocedurer. Vigtig for HVAC-teknikere og kølefagfolk.