Elcometer A415CFBI

Elcometer 415 Maling- og Pulverlakeringtykkelsesmåler Brugermanual

Model B Ferrous (A415CFBI)

1. Introduktion

The Elcometer 415 Industrial Paint & Powder Thickness Gauge is designed to provide simple, fast, and accurate coating thickness measurements on smooth and thin industrial paint and powder coatings. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device.

Elcometer 415 Paint & Powder Coating Thickness Gauge

Figure 1: The Elcometer 415 Paint & Powder Coating Thickness Gauge, showing its display and control buttons.

2. Sikkerhedsoplysninger

Please read and understand all safety instructions before operating the gauge. Failure to do so may result in injury or damage to the instrument.

  • Do not expose the gauge to extreme temperatures, direct sunlight, or high humidity.
  • Avoid dropping the instrument or subjecting it to severe impacts.
  • Keep the gauge away from strong magnetic fields.
  • Do not attempt to disassemble or repair the gauge yourself. Refer all servicing to qualified personnel.
  • Ensure the measurement surface is clean and free from debris to prevent damage to the probe and ensure accurate readings.
  • The gauge has an IP64 rating, indicating protection against dust ingress and splashing water from any direction. However, it is not waterproof and should not be submerged.

3. Hvad er der i æsken

Ved udpakning skal du kontrollere, at alle komponenter er til stede:

  • Elcometer 415 Gauge
  • Check Piece
  • Folie sæt

Hvis der mangler eller er beskadigede varer, bedes du straks kontakte din leverandør.

4. Opsætning

4.1. Første opstart

The Elcometer 415 Gauge is typically supplied with batteries pre-installed. To power on the device, press and hold the power button located on the front panel until the display illuminates.

4.2. Kalibrering

For accurate measurements, the gauge requires calibration. The Elcometer 415 supports both 1-point and 2-point calibration methods to ensure precision on smooth and thin coated substrates.

  1. 1-Point Calibration: This method is suitable for most applications. Place the gauge on a known uncoated substrate (e.g., the supplied check piece) and follow the on-screen prompts to set the zero point.
  2. 2-Point Calibration: For enhanced accuracy, especially on specific materials or thickness ranges, use the supplied foil set. First, perform a 1-point calibration. Then, place a foil of known thickness on the uncoated substrate and calibrate the second point according to the gauge's instructions.

Refer to the on-screen menu for detailed calibration procedures.

5. Operating the Gauge

5.1. At foretage en måling

Once calibrated, place the probe of the gauge firmly and perpendicularly onto the coated surface. The measurement will be displayed instantly on the screen. The gauge is capable of taking over 60 readings per minute, significantly reducing inspection times.

Elcometer 415 in use, measuring coating thickness on a surface

Figure 2: The Elcometer 415 Gauge being used to measure the thickness of a coating on a flat surface.

5.2. Fortolkning af display

The large, clear display shows the measurement in micrometers (µm) or mils (mils). Additional icons indicate battery status, measurement mode, and connectivity status (e.g., Bluetooth if applicable).

5.3. Data Logging and Transfer

The Elcometer 415 features data logging capabilities. Measurements can be stored internally and transferred to a computer via USB. Use the ElcoMaster software for instant report generation and further analysis of your data.

Elcometer 415 connected to a smartphone displaying measurement data

Figure 3: The Elcometer 415 Gauge displaying a measurement, with a smartphone showing detailed data analysis via the ElcoMaster app.

6. Vedligeholdelse

6.1. Rensning

To clean the gauge, wipe the exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the scratch, solvent, and powder resistant display. Ensure the probe tip is kept clean and free of debris for accurate readings.

6.2. Opbevaring

When not in use, store the Elcometer 415 in its protective case in a dry, cool environment, away from direct sunlight and extreme temperatures. Remove batteries if the gauge will not be used for an extended period to prevent leakage.

7. Fejlfinding

This section addresses common issues you might encounter with your Elcometer 415 Gauge.

ProblemMulig årsagLøsning
Gauge does not power on.Lave eller døde batterier.Udskift batterierne med nye. Sørg for korrekt polaritet.
Upræcise aflæsninger.Improper calibration; dirty probe tip; unstable surface.Recalibrate the gauge; clean the probe tip; ensure the surface is stable and flat.
Skærmen er svag eller flimrer.Lav batteristrøm.Udskift batterierne.
Cannot transfer data via USB.Incorrect cable; driver issue; ElcoMaster software not running.Ensure correct USB cable is used; install necessary drivers; open ElcoMaster software.

If the problem persists after attempting these solutions, please contact Elcometer customer support.

8. Specifikationer

FeatureDetalje
ModelElcometer 415 (Model B Ferrous)
VarenummerA415CFBI
MåleområdeUp to 1000µm (40mils) for cured paint & powder coatings
Målehastighed60+ readings per minute
MiljøbeskyttelseIP64 (Scratch, solvent, and powder resistant display)
DataoverførselUSB to ElcoMaster software
Kalibrering1-point and 2-point calibration

9. Garanti

The Elcometer 415 Gauge is manufactured to high quality standards. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Elcometer website. Extended protection plans may also be available for purchase separately.

10. Support

For technical assistance, product inquiries, or service requests, please contact Elcometer customer support. You can find contact information and additional resources on the official Elcometer webwebsted:

www.elcometer.com

Please have your model number (A415CFBI) and serial number ready when contacting support.

Relaterede dokumenter - A415CFBI

Preview Elcometer 415: 工业油漆和粉末涂层测厚仪 - 准确测量
Elcometer 415 工业油漆和粉末测厚仪提供简便、快速、准确的涂层厚度测量,适用于平滑及薄涂层基板,是工业质量控制的理想工具。
Preview Elcometer 415 Maling- og Pulvermåler Brugervejledning
Brugervejledning til Elcometer 415 maling- og pulvermåler, der beskriver dens funktioner, betjening, kalibrering, tekniske specifikationer og tilbehør til måling af lagtykkelse på glatte overflader.
Preview Elcometer 456 lagtykkelsesmåler: Funktioner, specifikationer og sonder
Omfattende overview af Elcometer 456 digital lagtykkelsesmåler, inklusive dens separate og integrerede modeller, funktioner, tekniske specifikationer, probekompatibilitet, tilbehør og kalibreringsmuligheder.
Preview Elcometer 456 Belægningstykkelsesmåler Brugsanvisning
Lær at bruge Elcometer 456 lagtykkelsesmåler med denne vejledning. Dækker funktioner, kalibrering, statistik, dataoverførsel og probedetaljer til præcis laginspektion.
Preview Elcometer 456 lagtykkelsesmåler | Digital filmtykkelsesmåling
Oplev Elcometer 456, en alsidig digital lagtykkelsesmåler, der tilbyder høj nøjagtighed, pålidelighed og effektivitet til måling af tørfilmtykkelse på forskellige underlag. Funktionerne omfatter et stort farvedisplay, flere sonder, datalogning og tilslutningsmuligheder med ElcoMaster-software.
Preview Elcometer 456 IPC brugervejledning: Industriel beskyttende lagtykkelsesmåler
Brugervejledning til Elcometer 456 IPC, med detaljerede oplysninger om funktioner, betjening, tekniske specifikationer og lovgivningsmæssige oplysninger til måling af industriel beskyttende belægningstykkelse.