1. Introduktion
The Frigga M2D Reusable Temperature Data Logger is a multi-use USB digital temperature recorder designed for accurate and reliable temperature monitoring. It features an advanced internal sensor with a measuring range of -22°F to +158°F (-30°C to +70°C) and a large data memory of 14400 readings. This device is ideal for monitoring temperatures in cold chain, food, pharmaceutical, and laboratory environments, ensuring temperature stability and product integrity.
The logger provides multiple ways to export data, including auto-generated PDF and CSV reports directly from the device, or through the complimentary Frigga Data Software for comprehensive analysis and customization.

Billede: Forside view of the Frigga M2D Reusable Temperature Data Logger with its USB cover open, displaying temperature readings and control buttons.
2. Pakkens indhold
Bekræft at alle varer er til stede i din pakke:
- 1x Frigga M2D Reusable Temperature Data Logger
- 1x brugermanual
3. Nøglefunktioner
- Multi-Use Temperature Data Logger: Advanced internal sensor provides a measuring range of -22°F ~ +158°F (-30°C ~+70°C), accuracy range: ±0.5℃ (-20℃~ +40℃); ±1℃ for other range and large data memory (14400 readings).
- Multiple Ways to Export Data Report: Easy to do the recording by pressing a button to start and stop. Plugging into a USB slot on any computer to get the PDF and CSV report directly without any software. All current and historical reports can also be exported via Frigga Data Center.
- Complimentary Companion Frigga Data Software: Compatible with Windows & Mac OS, the software allows setting logging conditions, charting, statistical analysis, and exporting data to Excel and PDF.
- Multi-Applications: Ideal for cold chain, food, pharmaceutical, or laboratory use—any application where accurate data logging is required.
- LED-alarmindikator: Alerts the user if the temperature goes beyond the pre-set threshold.
- Visual LCD Display: Displays real-time temperature readings, alarm status, and statistical type. Fahrenheit/Celsius can be switched.
- Langvarig batterilevetid: Equipped with a CR2450 battery for extended operation.

Image: Visual representation of the Frigga M2D's features, including data analysis, large capacity, temperature calibration report, temperature unit switch, IP65 waterproof grade, event mark, LED alarm, and zero data loss.
4. Opsætning og første brug
4.1. Initial Device Check
Before first use, short press the red "STOP" button. The screen will display "8888" to indicate it is ready.
Video: Frigga M2 Reusable Temperature Data Logger - This video demonstrates the physical features and basic initial checks of the data logger.
4.2. Software Installation (Frigga Data Center)
To fully configure your data logger and access advanced features, download the Frigga Data Center software. This software is compatible with both Windows and Mac OS.
- Go to the official Frigga website (friggatech.com) and navigate to the application download section.
- Download the "Frigga Data Center (Windows)" or "Frigga Data Center (Mac OS)" installer.
- Følg instruktionerne på skærmen for at fuldføre installationen.
Video: How to Download the Frigga Data Center? - This video guides you through the process of downloading and installing the Frigga Data Center software.
4.3. Configuring Device Parameters
Once the Frigga Data Center software is installed, connect your data logger to your computer via USB. You can then set various logging conditions such as recording intervals, temperature units, time zones, and temperature alarm ranges.

Image: The Frigga Data Center interface demonstrating how parameters like temperature unit, alarm ranges, and data storage settings can be configured.
5. Operating the Data Logger
5.1. Starting a Recording Session
To start the logger, long press the green "START" button for 10 seconds until the blue LED blinks and the screen displays "REC". Release the button within 40 seconds.

Image: Instructions for starting the logger by long-pressing the green START button until "REC" appears on the display.
5.2. Stopping a Recording Session
To stop the logger, long press the red "STOP" button for 5 seconds until the red LED blinks. Release the button within 40 seconds.
Alternatively, connecting the logger to a computer via USB will automatically stop the recording and generate a report.
5.3. Forståelse af LCD-skærmen
The LCD screen provides real-time information about the logger's status and recorded data. Key indicators include:
- SLEEP MODE: Display shows "8888".
- START FORSINKELSE: Indicates a programmed delay before recording begins.
- RECORDING MODE: Shows current temperature and humidity, along with "REC" indicator.
- GENERATING REPORT: Display shows "PDF" when connected to a computer and generating a report.
- STOP MODE: Display shows "StoP" when recording has ceased.

Image: Illustrations of the various display modes and indicators on the Frigga M2D's LCD screen, including sleep, start delay, recording, report generation, and stop modes.
6. Datahåndtering og rapportering
6.1. Eksport af datarapporter
The Frigga M2D offers several convenient methods for accessing your recorded temperature data:
- Auto-generated PDF & CSV: Simply plug the logger into any computer's USB port. The device will automatically generate and save PDF and CSV reports to the connected drive without requiring any special software.
- Export via Frigga Data Center Software: For more detailed analysis, charting, and statistical data, connect the logger to a computer running the Frigga Data Center software. This allows for comprehensive data review and export to various formats like PDF and Excel.
- Export via Frigga Cloud Platform: All current and historical reports can be uploaded to and exported from the Frigga Cloud Platform, providing remote access and centralized data management.

Image: The Frigga M2D connected to a laptop, illustrating the direct generation of PDF and CSV reports without additional software.
Video: How to Use the PC Tool - This video demonstrates how to use the Frigga Data Center software to manage, analyze, and export data from the logger.
6.2. FDA 21 CFR Part 11 Compliance
The Frigga Data Center software includes features to assist with FDA 21 CFR Part 11 compliance, which governs electronic records and electronic signatures. This module allows for secure data handling, user management, and audit trails.
Video: How to Enable FDA 21 CFR? - This video provides a guide on enabling and configuring the FDA 21 CFR Part 11 module within the Frigga Data Center software.
7. Vedligeholdelse
7.1. Udskiftning af batteri
The Frigga M2D data logger is equipped with a CR2450 battery. When the battery indicator on the LCD shows low power, it's time to replace it. Follow these steps:
- Find batterirummet på bagsiden af enheden.
- Brug en mønt eller et lille værktøj til at åbne batteridækslet.
- Fjern forsigtigt det gamle CR2450-batteri.
- Indsæt et nyt CR2450-batteri med den positive (+) side opad.
- Sæt batteridækslet på igen, og drej det for at fastgøre det.

Image: A step-by-step visual guide on replacing the CR2450 battery in the Frigga M2D data logger.
8. Fejlfinding
- Software Freezing/Not Opening: Ensure your operating system (Windows/Mac OS) meets the minimum requirements. Try running the software as an administrator. If issues persist, reinstall the software. Some users have reported issues with Windows 11; ensure you have the latest version of the Frigga Data Center.
- Enhed genkendes ikke af computeren: Ensure the USB connector is fully inserted. The protective USB cover, when open, might interfere with proper seating in some USB ports due to its size. Try a different USB port or a USB extension cable if necessary.
- Difficulty with Initial Setup/Parameter Reset: Refer to the detailed instructions in the official Frigga Data Center User Manual (available for download on the Frigga website). Ensure you are following the steps for setting up administrator accounts and user permissions if using the FDA 21 CFR module.
- No Data Exported: Confirm the logger has successfully stopped recording (display shows "StoP" or it was plugged into USB). Ensure the device is properly connected to the computer.
For yderligere hjælp henvises til den omfattende Frigga Data Center User Manual (PDF) or contact Frigga customer support.
9. Tekniske specifikationer
| Attribut | Værdi |
|---|---|
| Modelnummer | Frigga-M2D-1225-1pc |
| Måleområde | -22°F ~ +158°F (-30°C ~+70°C) |
| Nøjagtighedsområde | ±0.5℃ (-20℃~ +40℃); ±1℃ for other range |
| Hukommelseskapacitet | 14400 aflæsninger |
| Batteritype | 1 CR2450 batteri (medfølger) |
| Display Type | Digital LCD |
| Forbindelse | USB |
| Materiale | Plast |
| Særlige funktioner | Low Battery Indicator, Alarm, Fast Reading System, High Accuracy |
| Pakkedimensioner | 4.57 x 2.76 x 0.67 tommer |
| Varens vægt | 3.53 ounce |
| Oprindelsesland | Kina |

Image: A diagram illustrating the key product parameters including measurement range, accuracy range, and memory capacity.

Image: The Frigga M2D data logger shown with water splashing, highlighting its IP65 waterproof grade.
10. Garanti og support
For detailed warranty information, please refer to the official Frigga webwebsted eller kontakt kundesupport direkte.
Frigga provides 24/7 Technician Support via Email for any inquiries or issues you may encounter with your data logger.
Kontakt email: Please refer to the product packaging or official Frigga webwebstedet for den seneste support-e-mailadresse.