1. Introduktion
This manual provides essential information for the safe and effective installation, operation, and maintenance of your HEATIT 8PLSR Self-Regulating Heat Cable. This product is designed to provide frost protection for water pipes and assist with snow melting on roofs and gutters. Please read this manual thoroughly before installation and retain it for future reference.

Image 1.1: The HEATIT 8PLSR Self-Regulating Heat Cable, coiled, featuring its lighted plug indicator. This cable is designed for efficient frost protection and de-icing applications.

Image 1.2: Visual representation of the product's purpose: preventing frozen pipes and ensuring water flow during cold conditions.
2. Sikkerhedsoplysninger
ADVARSEL: Manglende overholdelse af disse sikkerhedsinstruktioner kan resultere i elektrisk stød, brand eller alvorlig personskade.
- Afbryd altid strømmen, før du installerer eller servicerer varmekablet.
- Do not cut or splice the heating cable.
- Do not use the cable if it is damaged. Inspect for cuts, abrasions, or other damage before installation.
- Ensure the cable is properly grounded.
- This product is intended for use with a 120V AC power supply.
- Consult local electrical codes and a qualified electrician for proper installation.
- The lighted plug indicates power is present, but not necessarily that the cable is actively heating. The cable heats only when the ambient temperature drops below a certain threshold.

Image 2.1: Illustration clarifying that the lighted plug indicates power is on, but the cable only heats when the thermostat senses low temperatures.
2.1 Certificeringer
The HEATIT 8PLSR Self-Regulating Heat Cable is fully ETL and UL certified, ensuring compliance with North American safety standards. This comprehensive certification covers the entire cable for reliable performance.

Image 2.2: Display of UL and ETL certification marks, indicating the product meets recognized safety standards.
3. Installationsvejledning
The HEATIT 8PLSR cable is designed for flexible installation on various pipe and roof types. It is self-regulating, pre-assembled, and can be overlapped without risk of overheating.

Image 3.1: Visual representation of flexible installation options for the heat cable, including spiral, straight, and wrapped configurations.
3.1 Pipe Freeze Protection
This cable is suitable for use on both plastic (Pex, ABS, PVC) and metal (Copper, Steel, Galvanized) water pipes. Ensure pipes are clean and dry before application.

Image 3.2: Types of pipes compatible with the HEATIT 8PLSR heat cable for freeze protection.
For optimal performance and energy efficiency, it is recommended to insulate the pipes after installing the heat cable. Use fiberglass insulation or foam pipe covers.
Installation Steps for Pipes:
- Ren overflade: Ensure the pipe surface is clean, dry, and free of sharp edges.
- Tilslut kabel: Secure the heat cable along the length of the pipe using electrical tape or cable ties at intervals of approximately 12 inches (30 cm). For plastic pipes, ensure the cable does not exceed 8W/ft.
- Spiral or Straight: The cable can be run straight along the bottom of the pipe or spiraled around it for increased heat output on larger diameter pipes or in colder conditions. Refer to the "Heating Cable Selection for Pipe Freeze Protection" table in the Specifications section for guidance on cable length per pipe diameter and temperature.
- Insulate: Apply appropriate insulation over the pipe and heat cable.
- Tilslut strøm: Plug the cable into a grounded 120V outlet. The lighted plug will illuminate to indicate power is present.
3.2 Roof and Gutter De-icing
The HEATIT 8PLSR cable can be used on various roof types, including metal, slate, stone, rubber, asphalt, ceramic, wood, and composite roofs, to prevent ice dams and facilitate snow melting.

Image 3.3: Illustration of a roof with snow, highlighting the potential for ice dam formation and associated damage, which the heat cable helps prevent.

Billede 3.4: Eks.amples of different roof materials compatible with the HEATIT 8PLSR heat cable for de-icing.
Installation Steps for Roofs and Gutters:
- Planlayout: Determine the areas prone to ice dam formation, typically roof edges, valleys, and gutters.
- Sikkert kabel: Use appropriate roof clips or fasteners (not included) to secure the cable in a zigzag pattern along the roof edge and inside gutters. Ensure the cable is not damaged during fastening.
- Calculate Length: Refer to the "Heating Cable Selection for Roof & Gutter De-icing" table in the Specifications section to calculate the required cable length based on roof edge length, gutter length, and downspout length.
- Tilslut strøm: Plug the cable into a grounded 120V outlet.

Image 3.5: The HEATIT 8PLSR cable provides efficient frost protection for pipes and de-icing for roofs and gutters.
4. Betjeningsvejledning
The HEATIT 8PLSR is a self-regulating heat cable. This means it automatically adjusts its heat output along its entire length based on the ambient temperature. It will produce more heat in colder sections and less heat in warmer sections, optimizing energy consumption and preventing overheating.
- Once plugged into a 120V power source, the integrated lighted plug will illuminate, indicating that the cable is receiving power.
- The cable will begin to heat when the temperature drops to a level where frost protection or de-icing is required.
- No manual adjustment is needed for temperature control.
- The self-regulating design allows the cable to be overlapped without causing hot spots or damage.

Image 4.1: Comparison illustrating the advantages of self-regulating heating cables, such as energy efficiency and the ability to overlap.
5. Vedligeholdelse
The HEATIT 8PLSR heat cable requires minimal maintenance due to its durable construction and self-regulating properties.
- Årlig inspektion: Before the cold season, visually inspect the entire length of the installed cable for any signs of damage, wear, or loose connections.
- Renhed: Ensure the cable and surrounding area are free from debris, leaves, or other materials that could impede heat transfer.
- Power Check: Verify that the lighted plug illuminates when connected to power. If it does not, check the power source.
- Undgå skader: Take care during roof cleaning or other maintenance activities to avoid cutting or damaging the cable.
6. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Cable not heating / Lighted plug off | No power to the outlet; Faulty outlet; Damaged cable or plug. | Check circuit breaker/GFCI. Test outlet with another device. Inspect cable for visible damage. If damaged, replace the cable. |
| Cable not heating sufficiently | Ambient temperature not low enough for full activation; Insufficient insulation; Incorrect cable length for application. | Verify ambient temperature is below freezing. Ensure pipes are adequately insulated. Review installation guidelines and cable length calculations. |
| Ice dams still forming on roof | Incorrect cable layout; Insufficient cable length; Extreme weather conditions. | Ensure cable is installed in a proper zigzag pattern. Verify sufficient cable length using the calculation table. Consider additional cable or professional assessment for extreme conditions. |
If troubleshooting steps do not resolve the issue, contact HEATIT customer service for assistance.
7. Specifikationer
- Model: 8PLSR
- Voltage: 120 volt
- Strømudgang: 8 watt/fod
- Materiale: Kobber leder
- Certificeringer: ETL & UL Listed
- Minimum installationstemperatur: -76°F (-60°C)
- Maksimal eksponeringstemperatur: 185°F (85°C)
- Kabellængde: 18 ft (This manual refers to the 18 ft variant, other lengths available)
- Farve: Sort
- Varens vægt: 2.31 pounds (for 18 ft variant)
- Pakkedimensioner: 9.09 x 8.86 x 2.64 inches (for 18 ft variant)

Image 7.1: The HEATIT 8PLSR heat cable's operational temperature range, from minimum installation to maximum exposure temperatures.
7.1 Heating Cable Selection for Pipe Freeze Protection
The following table provides guidance on the recommended cable length multiplier for different pipe diameters and lowest expected temperatures. This helps determine the total length of cable needed for effective pipe freeze protection.

Image 7.2: Guide for selecting appropriate heating cable length for pipe freeze protection based on pipe material, diameter, and minimum ambient temperature.
7.2 Heating Cable Selection for Roof & Gutter De-icing
Use the following table and formula to calculate the total heating cable length required for roof and gutter de-icing applications.

Image 7.3: Instructions and table for calculating the required heating cable length for roof and gutter de-icing, considering roof type and eave overhang.
8. Garanti og support
8.1 Garantioplysninger
HEATIT products are backed by a commitment to quality. Specific warranty details are typically provided with the product packaging. Please retain your proof of purchase for warranty claims.
8.2 Kundeservice
For any questions, technical assistance, or support regarding your HEATIT 8PLSR Self-Regulating Heat Cable, please contact HEATIT customer service. Our dedicated team aims to provide professional feedback within 24 hours.
Contact information can typically be found on the product packaging or the official HEATIT webwebsted.
9. Produktvideoer
No official product videos from the seller were provided in the available data to embed in this manual.