1. Introduktion
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your TOSOT Cosmo Series 36,000 BTU Quad 4 Zone Mini Split AC with Heat Pump. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide individual temperature control across four distinct zones using a single outdoor unit and four 9,000 BTU indoor units.
2. Sikkerhedsoplysninger
Vigtige sikkerhedsinstruktioner:
- Installation and maintenance must be performed by qualified, certified HVAC technicians in accordance with all local and national electrical and safety codes.
- Ensure the power supply matches the unit's specifications (230V).
- Forsøg ikke selv at reparere eller modificere enheden. Kontakt kvalificeret servicepersonale.
- Korrekt jordforbindelse er afgørende for at forhindre elektrisk stød.
- Sørg for korrekt ventilation omkring udendørsenheden.
- Hold børn og kæledyr væk fra udendørsenheden under drift.
- Refrigerant handling requires specialized tools and training.
3. Pakkens indhold
Verify that all components are present before beginning installation. Your TOSOT Cosmo Series system includes the following:
Indoor Unit Components (x4 sets)
- 1 x Indendørsenhed
- 5 x Gipsvægsanker
- 2 x Flare Nut
- 4 x Remote Holder Fixing Screw
- 5 x Mounting Plate Fixing Screw
- 2 x AAA batteri
- 1 x Remote Control Holder
- 1 x App Control Quick Guide
- 1 x fjernbetjening
- 1 x monteringsplade
- 1 x Insulation Sleeve
- 1 x 20 ft Signal Cable
Outdoor Unit Components (x1 set)
- 1 x Udendørsenhed
- 1 x Drain Joint
- 1 x brugermanual
Installation Accessories (x2 sets)
- 1 set x Refrigerant Pipe (16.4 ft copper line set)
- 1 x Sealing Gum
- 2 x tape
- 1 x afløbsslange
- 1 x vægmuffe

4. Opsætning og installation
The TOSOT Cosmo Series Mini Split system requires professional installation. While designed for easier installation compared to central AC systems, specific HVAC and electrical knowledge is necessary. The system includes a 16.4-foot copper line set for each indoor unit, but the power cord is not included and must be sourced separately.
4.1 Key Installation Steps
- Mounting Indoor Units: Securely mount each of the four indoor units in their designated zones, ensuring proper clearance for airflow and maintenance.
- Placering af udendørsenhed: Position the single outdoor unit on a stable, level surface, allowing adequate space for air circulation and service access.
- Refrigerant Line Set Connection: Connect the provided copper line sets between each indoor unit and the outdoor unit. This step requires precise flaring, torqueing, and the use of Nylog sealant to prevent leaks.
- Elektriske ledninger: Connect the electrical wiring according to the wiring diagram provided in the detailed user manual. Ensure the correct voltage (230V) and breaker size (e.g., 40A) are used.
- Støvsugning af systemet: Evacuate the refrigerant lines to remove air and moisture. This is a critical step for system efficiency and longevity. A vacuum pump must be used to pull a deep vacuum for at least 30 minutes per line set, and the vacuum must hold for at least an hour to confirm no leaks.
- Refrigerant Release: Once the vacuum test is successful, carefully release the R32 refrigerant from the outdoor unit into the system.
- Afløbsforbindelse: Ensure all indoor units have proper condensate drainage connected to prevent water leaks.


4.2 Kølemiddelinformation
This system utilizes R32 refrigerant, which has a 67% lower Global Warming Potential (GWP) and requires a 30% lower refrigerant charge compared to R410A systems, contributing to environmental benefits.

5. Betjeningsvejledning
Your TOSOT Mini Split system offers versatile climate control for up to four zones, with individual temperature settings and operating modes.
5.1 driftstilstande
The system supports the following modes:
- Køling: Provides cooling to maintain desired room temperature.
- Opvarmning: Functions as a heat pump, providing warmth even in extreme cold conditions (down to -22°F).
- Ventilator: Cirkulerer luft uden opvarmning eller afkøling.
- Affugtning: Reduces humidity levels in the room.

5.2 Temperaturkontrol
Each indoor unit can be set to a desired temperature between 61°F and 86°F (16°C and 30°C) independently. The advanced inverter technology ensures stable temperatures and quiet operation.

5.3 Smart kontrol
Manage your system from anywhere using the Gree+ app on your smartphone. The system also supports voice control for hands-free adjustments. Each indoor unit comes with its own remote control for direct adjustments.

6. Vedligeholdelse
Regular maintenance ensures optimal performance and longevity of your TOSOT Mini Split system.
6.1 Indoor Unit Maintenance
- Filterrensning: Clean the air filters every 2-4 weeks, or more frequently depending on usage and air quality. Refer to the detailed user manual for instructions on how to remove and clean the filters.
- Rengøring af spole: Periodically inspect and clean the indoor coil. This should ideally be done by a professional.
6.2 Vedligeholdelse af udendørsenhed
- Ryd affald: Keep the area around the outdoor unit clear of leaves, dirt, and other obstructions to ensure proper airflow.
- Rengøring af spole: Clean the outdoor coil annually, or as needed, to remove accumulated dirt and debris. This can be done with a garden hose, but avoid high-pressure sprays.
- Afløbskontrol: Ensure the drain pan and drain holes are clear to prevent water buildup.
7. Fejlfinding
If you encounter issues with your system, refer to the following basic troubleshooting steps. For complex problems, contact a qualified HVAC technician.
7.1 Almindelige problemer og løsninger
- Enheden tænder ikke: Kontroller strømforsyningen, afbryderen, og sørg for, at fjernbetjeningens batterier fungerer.
- Utilstrækkelig køling/opvarmning: Verify correct mode selection and temperature settings. Clean air filters. Ensure outdoor unit is not obstructed.
- Usædvanlige lyde: Minor noises during operation are normal. If loud or unusual noises occur, contact a technician.
- Vandlækager: Check indoor unit drainage hose for kinks or blockages. Ensure outdoor unit is level.
- Fjernbetjeningen virker ikke: Replace batteries. Ensure no obstructions between remote and indoor unit.
8. Specifikationer
Key technical specifications for the TOSOT Cosmo Series 36,000 BTU Quad 4 Zone Mini Split AC with Heat Pump (Model TST-MZ-M36-Q9999):
| Specifikation | Værdi |
|---|---|
| Mærke | TOSOT |
| Modelnummer | TST-MZ-M36-Q9999 |
| Systemtype | Quad 4 Zone Mini Split AC with Heat Pump |
| Samlet kapacitet | 36,000 BTU (3 tons) |
| Indoor Unit Capacity (each) | 9,000 BTU |
| SEER2-vurdering | 21 |
| HSPF2-vurdering | 10 |
| Voltage | 230 volt |
| Outdoor Unit Dimensions (D x W x H) | 40.2 cm x 16.8 cm x 32.5 cm |
| Varens vægt | 339 pund |
| Støjniveau (udendørsenhed) | 63 decibel |
| Driftstemperaturområde (opvarmning) | -22°F til 118°F |
| Kølevæsketype | R32 |
| Inkluderede komponenter | Remote, User Manual |
| Estimated Coverage Area | 1800 kvadratmeter |


9. Garanti og support
TOSOT provides a five-year warranty for this product, ensuring peace of mind regarding your investment. For any service inquiries, technical support, or warranty claims, please contact TOSOT customer service. It is recommended to arrange installation only after receiving all parts of your order, as shipments may arrive in multiple packages or on pallets at different times.
For detailed support, refer to the contact information provided in the full user manual included with your product or visit the official TOSOT webwebsted.