FOTING FT-JGP80035-F

FOTING 1 HP bærbar lavvandspumpe brugermanual

Model: FT-JGP80035-F

Indledning

Thank you for choosing the FOTING 1 HP Portable Shallow Well Pump. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your pump. Please read this manual thoroughly before first use and keep it for future reference.

Sikkerhedsinstruktioner

Overhold altid følgende sikkerhedsforanstaltninger for at mindske risikoen for personskade, elektrisk stød eller beskadigelse af pumpen.

  • Elektrisk sikkerhed: Ensure the power source matches the pump's requirements (115V AC). Do not operate with damaged cords or plugs. Always use a ground fault circuit interrupter (GFCI) for outdoor use.
  • Vandsikkerhed: This pump is designed for clean water only. Do not use with flammable, corrosive, or explosive liquids. Avoid running the pump dry; it is self-priming but requires initial priming.
  • Personlig sikkerhed: Wear appropriate personal protective equipment (PPE) such as gloves and eye protection during installation and maintenance. Keep children and pets away from the operating pump.
  • Placering: Place the pump on a stable, level surface. Ensure adequate ventilation around the pump. Protect the pump from freezing temperatures.
  • Opretholdelse: Disconnect power before performing any maintenance or cleaning. Refer to the maintenance section for proper procedures.
  • Automatic Thermal Overload Protection: The pump is equipped with built-in thermal overload protection. If the pump overheats, it will shut off automatically to prevent motor damage. Allow it to cool down before restarting.

Produkt overview

The FOTING 1 HP Portable Shallow Well Pump is a versatile and powerful solution for various water transfer needs, including garden irrigation, lawn sprinkling, and drawing water from shallow sources.

Komponenter

FOTING 1 HP Portable Shallow Well Pump

Figur 1: Hoved view of the FOTING 1 HP Portable Shallow Well Pump, showcasing dens kompakte design og integrerede håndtag.

  • Motor: 1 HP energy-efficient motor for powerful performance.
  • Pumpehus: Durable thermoplastic and aluminum construction for corrosion resistance.
  • Indløbs-/udløbsporte: 1" NPT water intake and outlet for standard connections.
  • Afbryderen: On/Off switch for easy operation.
  • Bærbart håndtag: Integreret håndtag for praktisk transport.
  • Strømkabel: 6.6 feet power cable for flexible placement.

Tekniske specifikationer

Technical Specifications of FOTING Shallow Well Pump

Figure 2: Detailed technical specifications including voltage, horsepower, flow rate, and maximum lift/suction.

SpecifikationVærdi
ModelnummerFT-JGP80035-F
Motorkraft1 HK
Voltage/Frekvens115V/60Hz
Max flowhastighed865 GPH (14.42 GPM)
Max sugehøjde26 FT
Max løftehøjde130 FT
Max tryk55 PSI (3.8 BAR)
Varens vægt14.24 pund
Produktdimensioner12.99 x 7.87 x 9.84 tommer
MaterialeThermoplastic, Aluminum

Præstationskarakteristika

Pump Working Performance Diagram

Figure 3: Diagram illustrating the pump's working performance, showing suction depth and lift height with corresponding flow rates.

Pump Performance Curve and Connection Methods

Figure 4: Graph showing the relationship between total head (FT) and flow rate (GPH), along with two common inlet connection methods for home use.

Opsætning og installation

Follow these steps for proper setup and installation of your FOTING Shallow Well Pump.

Pump Installation Steps

Figure 5: Visual guide for connecting the inlet pipe, priming the pump with water, and connecting the outlet pipe.

  1. Placering: Position the pump on a firm, level surface as close to the water source as possible to minimize suction lift. Ensure the area is well-ventilated and protected from direct sunlight and freezing temperatures.
  2. Tilslut indløbsrør: Attach a suitable inlet pipe (not included) to the 1" NPT water intake port. Ensure all connections are airtight to prevent air leaks, which can affect priming and performance. Use thread sealant tape for a secure seal.
    Close-up of Inlet and Outlet Ports

    Figur 6: Nærbillede view of the 1-inch NPT inlet and outlet ports.

  3. Forbered pumpen: Before first use, the pump must be fully primed. Remove the priming plug (usually located on top of the pump housing) and fill the pump casing completely with clean water until it overflows. Replace the priming plug securely. This step is crucial for self-priming pumps.
  4. Connect Outlet Pipe: Attach the desired outlet hose or pipe to the 1" NPT water outlet port. Ensure this connection is also secure.
  5. Elektrisk tilslutning: Plug the 6.6-foot power cable into a standard 115V AC grounded outlet. For outdoor applications, always use a GFCI protected outlet.

Betjeningsvejledning

Once the pump is properly installed and primed, follow these steps to operate it.

  1. Indledende kontrol: Before turning on the pump, double-check all connections for tightness and ensure the pump is fully primed with water.
  2. Tænd: Locate the power switch on the pump and switch it to the "ON" position.
    Close-up of Power Switch

    Figur 7: Nærbillede view of the pump's power switch.

  3. Monitordrift: The pump should begin to draw water and build pressure. Listen for unusual noises or vibrations, which may indicate an issue.
  4. Sluk: When you are finished using the pump, switch the power to the "OFF" position.
  5. Drainage (Seasonal Use): If the pump will not be used for an extended period or in freezing temperatures, drain all water from the pump and hoses to prevent damage.

Opretholdelse

Regular maintenance ensures the longevity and optimal performance of your FOTING pump.

  • Renhed: Hold pumpens yderside ren og fri for snavs.
  • Undersøg forbindelser: Periodically check all hose and pipe connections for leaks or damage. Tighten or replace as necessary.
  • Vinterisering: In cold climates, completely drain the pump and hoses before the first frost. Store the pump in a dry, warm place to prevent freezing and damage to internal components.
  • Motorkøling: Ensure the motor's cooling fins are clear of obstructions to allow for proper heat dissipation. The pump features fast cooling for extended life.
    Pump Internal Features: Blades, Cooling, Long Life

    Figure 8: Illustration highlighting the pump's high-quality blades, fast cooling system, and design for long service life.

Fejlfinding

Se tabellen nedenfor for almindelige problemer og deres løsninger.

ProblemMulig årsagLøsning
Pumpen starter ikkeNo power; Thermal overload tripped; Faulty switch.Check power connection and GFCI. Allow pump to cool if overloaded. Check switch.
Pumpen kører, men intet vand eller lavt flowPump not primed; Air leak in suction line; Suction lift too high; Clogged inlet/outlet.Re-prime the pump. Check all suction line connections for leaks. Reduce suction lift. Clear any blockages.
Pump cycles on and off frequentlySmall leak in system; Check valve issue.Inspect entire system for leaks. Check or replace check valve if present.
Overdreven støj eller vibrationerAir in pump; Loose mounting; Damaged impeller/bearings.Ensure pump is fully primed. Securely mount the pump. Contact customer support if internal damage is suspected.

Garanti og support

FOTING provides a warranty for this product against defects in material and workmanship. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official FOTING webwebsted.

If you encounter any issues or require technical assistance, please do not hesitate to contact FOTING customer support. Our team is dedicated to providing prompt and helpful solutions.

Kontaktoplysninger:

Please have your model number (FT-JGP80035-F) and purchase date ready when contacting support.

Relaterede dokumenter - FT-JGP80035-F

Preview Melnor XT 70360M Premium Metal Oscillerende Sprinkler - Brugervejledning
Detaljeret information og brugervejledning til Melnor XT 70360M Premium Metal Oscillating Sprinkler, der dækker funktioner som justerbar rækkevidde, rengørbar si og robust metalslæde.
Preview ALLFITHD AF-5026LS 26 cu. ft. Lawn Sweeper: Assembly, Operation & Warranty Guide
Comprehensive guide for the ALLFITHD AF-5026LS 26 cu. ft. Lawn Sweeper, covering safety, assembly instructions, operating procedures, maintenance, and warranty information.
Preview Manuale til installation og brug KINGGATES JET - Automazione Cancelli Battente
Scopri kommer installare og utilizzare in sicurezza il motoriduttore elettromeccanico KINGGATES JET per l'automazione di cancelli a battente. Fuldstændig vejledning til vejledning, avvertenze og caratteristiche teknik.
Preview Wisycom BFA Ultra-Wideband Booster User Manual and Specifications
Detailed user manual and specifications for the Wisycom BFA Ultra-Wideband UHF antenna booster with remote controlled filter bank. Covers setup, menu navigation, settings, variants, and technical specifications.
Preview KINGGATES JET: Automatisk svingportåbner - Tekniske specifikationer og installationsvejledning
Udforsk KINGGATES JET-serien, højtydende automatisering til svingporte op til 3 m og 600 kg. Har elegant italiensk design, robust mekanik, smart elektronik og nem installation. Inkluderer tekniske data, tilbehør og brugsgrænser.
Preview AL-KO JET F Gartenserienspumpen - Bedienungsanleitung & Technische Daten
Umfassende Bedienungsanleitung und technische Daten für AL-KO JET F Gartenpumpen (JET F 1000, JET F 1300, JET F 1400). Beinhaltet Einrichtung, Betrieb, Wartung, Sicherheit und Fehlerbehebung für effiziente Gartenbewässerung und Wassermanagement.