Inficon 724-202-G1

INFICON D-TEK Stratus Refrigerant Leak Detector and Portable Monitor User Manual

Model: 724-202-G1

1. Introduktion

The INFICON D-TEK Stratus is an advanced refrigerant leak detector and portable monitor designed for efficient and accurate leak detection. This device combines the precision of D-TEK Select detectors with the broad area scanning capability of a portable monitor, offering a comprehensive solution for identifying refrigerant leaks.

It features an infrared sensor, dual operating modes (Cloud Hunting and Pinpoint), and a robust design for field use. This manual provides essential information for the proper setup, operation, and maintenance of your D-TEK Stratus unit.

2. Nøglefunktioner

  • Dobbelte driftstilstande: Cloud Hunting mode for locating the general area of highest concentration and Pinpoint mode for precise leak identification.
  • Advanced Infrared Sensor: Redesigned for enhanced performance and an extended lifespan of over 2,000 hours.
  • Høj følsomhed: Detects leaks as small as 0.03 oz./year (1 g/year) without degradation over time.
  • Versatile Refrigerant Detection: Compatible with CFCs, HCFCs, HFCs, HFOs, and A2Ls. Optional sensors are available for CO2 and flammable refrigerants.
  • Feltudskiftelige komponenter: Sensor, battery, filters, and probe are easily replaceable in the field.
  • Lithium-ion batteri: Provides extended operation with quick charge capability.
  • Brugervenlig grænseflade: Large, easy-to-read LCD display and intuitive controls.
  • Automatic and Manual Zero Modes: For optimal calibration in various environments.

3. Pakkens indhold

Når du åbner pakken, skal du kontrollere, at alle følgende varer er inkluderet:

INFICON D-TEK Stratus package contents including the device, chargers, earbuds, and carry case.

Image: The INFICON D-TEK Stratus device shown with its complete set of accessories, including the main unit, various international AC wall chargers, a DC car charger, earbuds, spare filters, an extra-long probe, an infrared sensor, a lithium-ion battery, and a durable carry case.

  • D-TEK Stratus Unit
  • Infrared Sensor (pre-installed or separate)
  • Lithium-Ion Battery (pre-installed or separate)
  • AC Wall Charger (US & International adapters)
  • DC billader
  • Extra-Long Probe
  • Øretelefoner
  • Reservedele
  • Bæretaske

4. Opsætning

4.1 Indledende opladning

Before first use, fully charge the lithium-ion battery. Connect the provided AC wall charger or DC car charger to the micro USB power input port on the device. The charging indicator on the display will show the charging status.

4.2 Sensor and Filter Installation

Ensure the infrared sensor and filter are correctly installed. The sensor is typically pre-installed. Filters are located at the probe tip and should be clean and free of debris for optimal performance.

INFICON D-TEK Stratus Refrigerant Leak Detector

Image: The INFICON D-TEK Stratus device, showing its main body, flexible probe, and digital display indicating a refrigerant concentration of 1345 ppm. This image highlights the device's ergonomic design and clear interface.

4.3 Enhed overview

Familiarize yourself with the device's controls and components:

INFICON D-TEK Stratus device components labeled

Billede: En detaljeret view of the INFICON D-TEK Stratus, with labels pointing to key components such as the probe tip/filter, headphone jack, volume button, battery cover, eject button, micro USB power input, SENS/ZERO button, and Mode/Max button. The power button is indicated as not visible in this view.

  • Power knap: Tænder/slukker enheden.
  • Mode/Max Button: Toggles between Cloud Hunting and Pinpoint modes, and displays maximum readings.
  • SENS/ZERO Button: Adjusts sensitivity and performs manual zeroing.
  • Hovedtelefonstik: For connecting earbuds for audio alerts.
  • Lydstyrke knap: Adjusts audio alert volume.
  • Micro USB strømindgang: Til opladning af enheden.
  • Skub ud knap: Releases the sensor module for replacement.
  • Batteridæksel: Giver adgang til batterirummet.
  • Probe Tip/Filter: The detection point, containing a replaceable filter.

5. Betjeningsvejledning

5.1 Tænding og indledende kalibrering

  1. Tryk og hold tænd/sluk-knappen nede for at tænde enheden.
  2. Allow the device to warm up and perform its automatic zeroing process in a clean, leak-free environment. This ensures accurate readings.

5.2 driftstilstande

The D-TEK Stratus offers two distinct operating modes for efficient leak detection:

INFICON D-TEK Stratus Cloud Hunting and Pinpoint Modes

Image: This graphic illustrates the two primary operating modes of the INFICON D-TEK Stratus. The top section shows "Cloud Hunting Mode" with a digital display indicating 1345 ppm, used for finding areas of highest concentration. The bottom section shows "Pinpoint Mode" with a color-coded bar graph, used for precisely locating the leak source.

5.2.1 Cloud Hunting Mode

  • Use this mode to quickly scan large areas and identify the general vicinity of a refrigerant leak.
  • The display will show refrigerant concentration in parts per million (ppm).
  • Move the probe slowly through the suspected area. Higher readings indicate proximity to a leak.

5.2.2 Pinpoint Mode

  • Once the general leak area is identified using Cloud Hunting, switch to Pinpoint mode for precise leak location.
  • In this mode, the device provides a more focused indication, often with a visual bar graph or escalating audio tone, to guide you directly to the leak source.
  • Move the probe very slowly and methodically around suspected leak points.

5.3 Adjusting Sensitivity and Zeroing

  • Følsomhed: Press the SENS/ZERO button to cycle through sensitivity levels. Adjust sensitivity based on the size of the suspected leak and environmental conditions.
  • Manual Zero: If the device is alarming in a clean environment, move the probe to an area free of refrigerants and press and hold the SENS/ZERO button to perform a manual zero.

6. Sensorinformation

The D-TEK Stratus utilizes an advanced infrared sensor for detecting a wide range of refrigerants. The sensor has an expected lifespan of over 2,000 hours.

6.1 Compatible Refrigerants

The standard infrared sensor detects:

  • CFCs (Chlorofluorocarbons)
  • HCFCs (Hydrochlorofluorocarbons)
  • HFCs (Hydrofluorocarbons)
  • HFOs (Hydrofluoroolefins)
  • A2Ls (Mildly Flammable Refrigerants)

6.2 valgfri sensorer

For detecting other gases, optional sensors are available and can be easily interchanged:

INFICON D-TEK Stratus interchangeable sensors

Image: This image displays three different sensor modules for the INFICON D-TEK Stratus. The red sensor is for CFCs, HCFCs, HFCs, HFOs, and A2Ls (included refrigerant sensor). The silver sensor is for flammable refrigerants (requires optional sensor). The green sensor is for CO2 (requires optional sensor). This illustrates the device's versatility with interchangeable sensors.

  • CO2 sensor: Required for detecting Carbon Dioxide.
  • Flammable Refrigerants Sensor: Required for detecting flammable refrigerants.

7. Batterioplysninger

The D-TEK Stratus is powered by a rechargeable Lithium-Ion battery, providing approximately 9 hours of continuous operation on a full charge. The battery is designed for quick charging.

7.1 Opladning

Use only the INFICON-supplied AC wall charger or DC car charger. Connect the charger to the micro USB port on the device. The battery indicator on the display will show the charging status.

7.2 Udskiftning af batteri

The Lithium-Ion battery is field replaceable. Refer to the maintenance section for instructions on how to safely replace the battery.

8. Vedligeholdelse

Regular maintenance ensures the longevity and accuracy of your D-TEK Stratus.

8.1 Filterudskiftning

The probe tip contains a filter that prevents contaminants from entering the sensor. Replace the filter regularly, especially if operating in dusty or dirty environments, or if you notice a decrease in sensitivity. Spare filters are included with your unit.

  1. Gently unscrew the probe tip.
  2. Fjern det gamle filter.
  3. Indsæt et nyt filter.
  4. Screw the probe tip back on securely.

8.2 Udskiftning af sensor

The infrared sensor is field replaceable. When the sensor reaches the end of its lifespan (indicated by a message on the display or persistent inaccurate readings), it should be replaced.

  1. Sørg for, at enheden er slukket.
  2. Locate the eject button (refer to Device Overview).
  3. Press the eject button to release the sensor module.
  4. Carefully remove the old sensor.
  5. Insert the new sensor module, ensuring it clicks into place.
  6. Power on the device and allow it to calibrate with the new sensor.

8.3 Rengøring

Tør enhedens ydre af med adamp cloth. Do not use abrasive cleaners or solvents. Ensure the probe tip and sensor area remain clean and free of obstructions.

9. Fejlfinding

If you encounter issues with your D-TEK Stratus, consider the following common solutions:

  • Enheden tænder ikke:
    • Sørg for, at batteriet er fuldt opladet.
    • Kontroller om batteriet er korrekt installeret.
  • Unøjagtige aflæsninger eller konstant alarm:
    • Perform a manual zero in a clean air environment.
    • Check and replace the probe tip filter if it is dirty or clogged.
    • Verify the sensor is correctly installed and not at the end of its lifespan.
    • Ensure the correct sensor type is installed for the refrigerant being detected.
  • Ingen detektion:
    • Øg følsomhedsindstillingen.
    • Ensure the probe is moved slowly and methodically.
    • Check the sensor for proper installation and remaining lifespan.
    • Confirm the presence of refrigerant; test with a known leak source if possible.
  • Kort batterilevetid:
    • Sørg for, at batteriet er fuldt opladet før brug.
    • Consider replacing the battery if it no longer holds a charge effectively.

For persistent issues, contact INFICON customer support.

10. Specifikationer

MærkeInficon
Modelnummer724-202-G1
StilOvervåge
StrømkildeBatteridrevet (lithium-ion)
FarveRåhvid
Produktdimensioner4" D x 8" B x 12" H
Varens vægt2.1 ounce
AlarmtypeVisuel
Driftsfugtighed95% RH NC Max
SensortypeInfrarød
Sensorens levetid> 2,000 timer
Følsomhed0.03 oz./year (1 g/year)
Gennemsnitlig batterilevetid9 timer
UPC810044830330

11. Garanti og support

INFICON stands behind the quality of its products.

INFICON D-TEK Stratus warranty and support information

Image: This graphic highlights INFICON's commitment to quality and customer support. It features icons and text indicating a "2 Year Replacement Warranty," "Made in the USA with US and Imported Parts," and "US Technician Support" available via email and phone.

11.1 Garantioplysninger

The INFICON D-TEK Stratus comes with a Two-Year Replacement WarrantyDenne garanti dækker materiale- og fabrikationsfejl ved normal brug. Gem venligst din købsbevis i tilfælde af garantikrav.

11.2 Teknisk support

For technical assistance, troubleshooting, or warranty inquiries, please contact INFICON US Technician Support. Support is available via email and phone.

The product is proudly Fremstillet i USA with a combination of US and imported parts, reflecting a commitment to quality manufacturing.

Relaterede dokumenter - 724-202-G1

Preview INFICON HVAC/R serviceværktøjskatalog: Lækagedetektorer, vakuumpumper og mere
Udforsk det omfattende udvalg af INFICON HVAC/R serviceværktøjer, herunder avancerede kølemiddellækagedetektorer (D-TEK-serien, TEK-Mate), vakuumpumper (QS5), genvindingsmaskiner (Vortex Dual), forbrændingsanalysatorer (FLUE-Mate) og kuliltemålere (CO Check).
Preview INFICON D-TEK Stratus Kølemiddellækagedetektor Brugsanvisning
Denne betjeningsvejledning indeholder omfattende instruktioner til INFICON D-TEK Stratus kølemiddellækagedetektor og bærbar monitor, der dækker dens funktioner, betjening, vedligeholdelse og fejlfinding.
Preview INFICON D-TEK Stratus Refrigerant Leak Detector Quick Start Guide
Quick start guide for the INFICON D-TEK Stratus Refrigerant Leak Detector and Portable Monitor, covering operation, modes, battery, sensor, and filter replacement.
Preview INFICON TEK-Mate Refrigerant Leak Detector Operating Manual
Operating manual for the INFICON TEK-Mate Refrigerant Leak Detector, covering setup, operation, troubleshooting, specifications, and warranty information.
Preview INFICON D-TEK Pro Kølemiddellækagedetektor Brugsanvisning
Omfattende betjeningsvejledning til INFICON D-TEK Pro kølemiddellækagedetektor, der dækker dens funktioner, betjening, vedligeholdelse og fejlfinding.
Preview INFICON D-TEK 3 Kølemiddellækagedetektor Lynstartguide
En hurtigstartguide til INFICON D-TEK 3 kølemiddellækagedetektor, der dækker opsætning, driftstilstande, håndtering af batteri og sensor samt opladningsoplysninger.