1. Introduktion
This manual provides essential information for the safe and efficient operation and maintenance of your VIVOHOME 1/2 HP 3200GPH Automatic Pool Cover Pump. Please read these instructions thoroughly before installation and use, and retain them for future reference.
2. Sikkerhedsoplysninger
- Afbryd altid pumpen fra strømforsyningen, før du udfører vedligeholdelse eller rengøring.
- Sørg for, at netledningen og stikket er i god stand. Må ikke anvendes, hvis de er beskadiget.
- This pump is designed for water only. Do not use it for flammable liquids, corrosive chemicals, or water containing excessive debris like mud or large gravel.
- Do not run the pump dry. The automatic switch is designed to prevent this, but always monitor operation.
- Hold børn og kæledyr væk fra pumpen under drift.
- The pump is equipped with thermal overload protection. If it stops unexpectedly, allow it to cool down before restarting.
- Ensure the electrical outlet is properly grounded and protected by a Ground Fault Circuit Interrupter (GFCI).
3. Pakkens indhold
Bekræft at alle komponenter er til stede:
- VIVOHOME 1/2 HP 3200GPH Automatic Pool Cover Pump
- 25 FT netledning
- Adaptor x 3 (various sizes for hose connection)
- Clamp x 2
- Sealing Ring x 2
- 90° Connector x 1
4. Specifikationer
| Feature | Specifikation |
|---|---|
| Mærke | VIVOHOME |
| Modelnummer | VH1283CA-NEW |
| Strømkilde | Elektrisk med ledning |
| Voltage | 120 volt (AC) |
| Wattage | 372.8 watt |
| Hestekræfter | 1 / 2 HP |
| Maksimal flowhastighed | 3200 Gallons Per Hour (53.3 Gallons Per Minute) |
| Maksimalt hoved | 21 fod |
| Varens vægt | 8.1 pund |
| Produktmål (L x B x H) | 9.8 cm L x 9.8 cm B x 8.9 cm H |
| Kabellængde | 25 fod |
| Materiale | Acrylonitrilbutadienstyren (ABS), polypropylen (PP) |
| Stil | Automatisk tænd/sluk |

Figur 1: Product dimensions and package specifications. This image provides a visual representation of the pump's physical dimensions (length, width, height) and cable length, along with package dimensions and weight.
5. Opsætning
5.1 Udpakning og inspektion
Carefully remove all components from the packaging. Inspect the pump and accessories for any signs of damage. If any damage is found, do not proceed with installation and contact customer support.
5.2 Slangetilslutning
The pump includes various adaptors, seals, and clamps to connect to different hose sizes. For optimal flow rate, it is recommended to use 1-1/2" or 1-1/4" garden hoses. The 90° connector is useful for operating in tight spaces.
- Select the appropriate adaptor for your hose size.
- Attach the adaptor to the pump's discharge port. Use a sealing ring to ensure a watertight connection.
- Secure the hose to the adaptor using the provided clamps. Ensure a tight fit to prevent leaks.
- If needed, attach the 90° connector before the adaptor for angled discharge.

Figur 2: Included accessories for hose connection. This image displays the pump with its various connectors, clamps, and sealing rings, illustrating how different hose sizes can be attached for drainage.
5.3 Pumpeplacering
Place the pump on a stable, flat surface in the area to be drained. The detachable strainer base helps keep the pump off the bottom surface and prevents leaves and debris from entering the pump body. Ensure the pump is fully submerged in water before connecting power.

Figur 3: The VIVOHOME 1/2 HP 3200GPH Automatic Pool Cover Pump. This image shows the complete pump unit with its power cord and discharge port, ready for connection.

Figur 4: The pump in operation, effectively draining water from a pool. This image demonstrates the pump submerged in water, with water being discharged through an attached hose.
5.4 Strømtilslutning
Connect the 25ft power cord to a standard 120V AC grounded electrical outlet. For safety, ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI).
6. Betjeningsvejledning
6.1 Automatisk drift
The VIVOHOME pump features an automatic ON/OFF switch designed to prevent dry running and protect against water shortage. The pump will:
- Start automatisk when the water level reaches approximately 4/5" (20mm).
- Stop automatically when the water level drops below approximately 2/5" (10mm).

Figur 5: Automatic switch mechanism. This diagram illustrates how the pump's automatic sensor activates when water reaches 4/5" and deactivates when it falls below 2/5", preventing dry operation.
6.2 Thermal Overload Protection
The pump is equipped with an overheating protection device to prevent damage. If the internal temperature reaches 221°F (105°C), the pump will stop operating automatically. It will resume operation once the temperature drops to 167°F (75°C) or below. This feature extends the service life of the pump and ensures user safety.

Figur 6: Thermal overload protection system. This image shows a cutaway view of the pump, highlighting the thermal sensor that stops the pump at 221°F and restarts it at 167°F.
6.3 High Flow Rate
The 1/2 HP motor provides a high flow rate of up to 3200 Gallons Per Hour (GPH), making it efficient for draining large volumes of water. The pump is designed to handle water with small debris, but it is not recommended for extreme conditions with heavy garbage or mud.

Figur 7: High flow rate and debris handling. This diagram illustrates the pump's internal mechanism and its ability to process water with small amounts of mud, rubbish, and weed, achieving a 3200 GPH flow rate.
6.4 Ansøgninger
This submersible water pump is suitable for various draining tasks, including:
- Swimming pool covers
- Ground swimming pools
- Spabade
- Kældere
- Tage
- Water beds
- Ponds (ensure a mesh filter bag is used if small stones or gravel are present)
7. Vedligeholdelse
7.1 Cleaning the Strainer Base
The detachable strainer base can effectively filter leaves and debris, preventing clogging. Regularly inspect and clean the strainer base to maintain optimal pump performance. To clean:
- Afbryd pumpen fra strømforsyningen.
- Fjern pumpen fra vandet.
- Detach the strainer base by twisting or unlatching it (refer to product diagram for specific mechanism).
- Rinse the strainer base and the pump's intake area with clean water to remove any accumulated debris.
- Reattach the strainer base securely before next use.
7.2 Vinterisering
The pump is equipped with automatic freeze protection, allowing it to function normally even in winter conditions. However, for prolonged storage or in extremely harsh freezing conditions, it is recommended to:
- Tøm alt vand ud af pumpen og slangen.
- Rengør pumpen grundigt.
- Opbevar pumpen et tørt og frostfrit sted.
8. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Pumpen starter ikke | Ingen strømforsyning Vandstanden er for lav Termisk overbelastning aktiveret | Check power connection and GFCI Ensure water level is above 4/5" Allow pump to cool down (resets automatically) |
| Low flow rate or no water discharge | Clogged strainer base Kinked or blocked hose Incorrect hose size Luftlås | Clean strainer base Check and clear hose obstruction Use recommended hose sizes (1-1/4" or 1-1/2") Ensure pump is fully submerged and tilted slightly to release air |
| Pump runs continuously even when water is low | Automatic switch malfunction Sensor blokeret | Inspect the automatic switch mechanism for debris or damage. If problem persists, contact customer support. |
| Usædvanlig støj eller vibrationer | Affald i pumpehjulet Pump not stable | Disconnect power, inspect and clear impeller area Ensure pump is on a flat, stable surface |
9. Garanti og support
For warranty information or technical support, please refer to the warranty card included with your product or contact VIVOHOME customer service directly. Keep your purchase receipt as proof of purchase.
VIVOHOME Customer Service: Visit the VIVOHOME Store on Amazon