APC BE900G3, BE500G3

APC Back-UPS Series User Manual

Models: BE900G3 (900VA) and BE500G3 (500VA)

1. Introduktion

This user manual provides essential information for the installation, operation, and maintenance of your APC Back-UPS Series uninterruptible power supply (UPS). This series includes two models: the BE900G3 (900VA/540W) og den BE500G3 (500VA/300W). Both models are designed to protect your electronic equipment from power outages, surges, and spikes, ensuring continuous operation and safe shutdown of connected devices.

Please read this manual thoroughly before installing or operating your Back-UPS unit. Keep this manual for future reference.

2. Sikkerhedsoplysninger

Observe the following safety precautions during installation and operation of your UPS unit:

  • Elektrisk sikkerhed: Connect the UPS to a grounded outlet only. Do not remove the grounding prong from the power cord.
  • Kun indendørs brug: This UPS is intended for indoor use in a controlled environment. Avoid exposure to excessive moisture, direct sunlight, or extreme temperatures.
  • Batterisikkerhed: The battery contains hazardous chemicals. Refer to the Maintenance section for battery replacement instructions. Do not dispose of batteries in a fire; they may explode.
  • Ventilation: Ensure adequate airflow around the UPS. Do not block ventilation openings.
  • Overbelaste: Do not overload the UPS. Refer to the Specifications section for maximum load capacity.

3. Produktet er slutview

The APC Back-UPS Series provides reliable power protection for your home or small office electronics. Both models feature battery backup outlets, surge-only outlets, and USB charging ports.

3.1. Model BE900G3 (900VA / 540W)

This higher-capacity model is suitable for multiple PCs, networking equipment, and home entertainment systems. It offers extended runtime for critical devices.

  • Samlet antal udsalgssteder: 8 (NEMA 5-15R)
  • Stikkontakter til batteribackup og overspændingsbeskyttelse: 6
  • Kun stikkontakter med overspændingsbeskyttelse: 2
  • USB -opladningsporte: 1 USB-C, 1 USB-A (5V/3A Shared)
  • User Replaceable Battery: Yes (RBC17)
  • Dataport: For PowerChute UPS management software (Windows 10, 11 Pro; Mac OS uses native Energy Saver settings)
APC Back-UPS BE900G3 showing outlets and USB ports

Billede: Forside view of the APC Back-UPS BE900G3, illustrating the arrangement of battery backup outlets, surge-only outlets, and the USB-C and USB-A charging ports on the side panel.

3.2. Model BE500G3 (500VA / 300W)

This compact model is ideal for essential devices such as routers, modems, and internet phones, ensuring connectivity during brief power interruptions.

  • Samlet antal udsalgssteder: 6 (NEMA 5-15R)
  • Stikkontakter til batteribackup og overspændingsbeskyttelse: 4
  • Kun stikkontakter med overspændingsbeskyttelse: 2
  • USB -opladningsporte: 1 USB-C, 1 USB-A (5V/3A Shared)
  • User Replaceable Battery: Yes (RBC17)
APC Back-UPS BE500G3 compact unit

Image: A compact APC Back-UPS BE500G3 unit, showcasing its smaller form factor compared to the BE900G3.

3.3. Fælles funktioner

  • Automatisk voltage Forordning (AVR): Corrects minor voltage fluctuations without using battery power, extending battery life.
  • Overspændingsbeskyttelse: Protects connected equipment from damaging power surges and spikes.
  • Afbryder: Resettable circuit breaker for overload protection.
  • Building Wiring Fault Indicator: Alerts to potential wiring issues in the wall outlet.
Bag view of APC Back-UPS showing data port and circuit breaker

Billede: Bagside view of an APC Back-UPS unit, highlighting the data port for communication with a computer and the resettable circuit breaker button.

4. Opsætning

Follow these steps to set up your APC Back-UPS unit:

  1. Pak UPS'en ud: Carefully remove the UPS and all accessories from its packaging. Inspect for any shipping damage.
  2. Tilslut batteriet: The battery may be disconnected for shipping. Refer to the Maintenance section for instructions on connecting the internal battery.
  3. Indledende opkrævning: Plug the UPS power cord into a grounded wall outlet. Allow the unit to charge for at least 24 hours before connecting any equipment to ensure maximum battery runtime. The UPS will charge whether it is turned on or off.
  4. Tilslut udstyr:
    • Stikkontakter til batteribackup og overspændingsbeskyttelse: Connect critical equipment such as computers, monitors, routers, and modems to these outlets. These devices will receive power from the battery during an outage.
    • Kun stikkontakter med overspændingsbeskyttelse: Connect non-critical equipment like printers, scanners, or lamps to these outlets. These outlets provide surge protection but no battery backup.
  5. Connect USB Charging Ports: Use the USB-C and USB-A ports to charge compatible mobile devices.
  6. (BE900G3 Only) Connect Data Port: For advanced power management and automatic shutdown features, connect the supplied USB cable from the UPS data port to your computer. Install APC PowerChute software (available for Windows) or configure native energy saver settings (for Mac OS).
  7. Turn On the UPS: Press the power button on the front of the unit. The power indicator will illuminate.
APC Back-UPS integrated into a home entertainment setup

Image: An APC Back-UPS unit positioned within a home entertainment system, demonstrating how various devices like a TV and media players can be connected for power protection.

5. Betjeningsvejledning

5.1. Tænd/sluk-knap og indikatorer

The front panel features a power button and LED indicators that provide status information:

  • Power knap: Press to turn the UPS on or off.
  • Power On-indikator: Illuminates when the UPS is on and receiving utility power.
  • Indikator for batteri på: Flashes or illuminates when the UPS is operating on battery power during an outage.
  • Overbelastningsindikator: Illuminates if the connected load exceeds the UPS capacity.
  • Building Wiring Fault Indicator: Illuminates if there is a wiring problem in the wall outlet (e.g., missing ground).
Close-up of APC Back-UPS outlets and control panel

Billede: En detaljeret view of the APC Back-UPS control panel, showing the power button, LED indicators, and the USB charging ports.

5.2. Automatisk Voltage Forordning (AVR)

Your Back-UPS unit includes AVR, which automatically corrects minor voltage fluctuations (sags and surges) without switching to battery power. This feature helps to preserve battery life and ensures a stable power supply to your connected devices.

5.3. Power Outage Betjening

Under en magt outage, the UPS will automatically switch to battery power. An audible alarm will sound, and the 'On Battery' indicator will illuminate. The alarm will typically sound every 30 seconds. When utility power returns, the UPS will automatically switch back to utility power and recharge its battery.

Hvis magten outage is prolonged, save your work and shut down your computer and other connected devices gracefully before the UPS battery is depleted. The BE900G3, when connected via its data port, can initiate an automatic shutdown of your computer.

6. Vedligeholdelse

6.1. Udskiftning af batteri

The batteries in your APC Back-UPS are user-replaceable. The typical battery life is 3-5 years, depending on usage and environmental conditions. When the battery needs replacement, the UPS will typically indicate this with an audible alarm and/or an LED indicator.

Replacement Battery Model: RBC17 (sold separately)

Procedure:

  1. Turn off the UPS and disconnect it from the wall outlet.
  2. Frakobl alt tilsluttet udstyr fra UPS'en.
  3. Locate the battery compartment (usually on the bottom or side of the unit).
  4. Follow the instructions on the battery compartment cover to open it and disconnect the old battery.
  5. Insert the new RBC17 battery, ensuring correct polarity.
  6. Close the battery compartment and reconnect the UPS to the wall outlet. Allow it to charge for 24 hours.

Advarsel: Only use genuine APC replacement batteries. Using non-APC batteries may void your warranty and could be unsafe.

6.2. Rensning

Rengør UPS'ens yderside med en blød, tør klud. Brug ikke flydende rengøringsmidler eller rengøringsmidler på aerosolbasis. Sørg for, at ventilationsåbningerne er fri for støv og snavs.

6.3. Opbevaring

If storing the UPS for an extended period, charge the battery for 24 hours every 3-6 months to prevent battery degradation.

7. Fejlfinding

Se tabellen nedenfor for almindelige problemer og løsninger på disse:

ProblemMulig årsagLøsning
UPS'en tænder ikkeBatteri ikke tilsluttet eller afladetEnsure battery is connected. Plug UPS into wall outlet and charge for 24 hours.
UPS beeps continuously or 'Overload' LED is onOverbelastningstilstandDisconnect non-essential equipment from battery backup outlets. Reduce the total load.
UPS leverer ikke forventet driftstidBattery is old or not fully chargedReplace battery if old. Ensure UPS is charged for 24 hours.
'Building Wiring Fault' LED is onWiring problem in wall outletConsult a qualified electrician to inspect the building wiring.
UPS is on but connected devices are not poweredStrømafbryder udløstPress the circuit breaker button on the rear of the UPS to reset it.

8. Specifikationer

FeatureBE900G3BE500G3
Kapacitet (VA/Watt)900VA / 540W500VA / 300W
Input bindtage120V AC120V AC
Udgang Voltage (På batteri)120V AC120V AC
Total Outlets8 (NEMA 5-15R)6 (NEMA 5-15R)
Batteribackup-udtag64
Kun overspændingsudtag22
USB-opladningsporte1 USB-C, 1 USB-A (5V/3A Shared)1 USB-C, 1 USB-A (5V/3A Shared)
Brugerudskifteligt batteriYes (RBC17)Yes (RBC17)
DataportUSB (for PowerChute)Ingen
FormfaktorKompaktKompakt
FarveHvidHvid
Strømstik typeType B - 3-benet (nordamerikansk)Type B - 3-benet (nordamerikansk)

9. Garanti og support

APC provides a standard warranty for its Back-UPS products. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official APC webwebsted. Gem din købsbevis til garantikrav.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact APC Customer Support through their official webwebstedet eller kontaktoplysningerne på din produktemballage.

Relaterede dokumenter - BE900G3, BE500G3

Preview APC Back-UPS BN450MNW Brugermanual: Installation, betjening og fejlfinding
Omfattende brugermanual til APC Back-UPS BN450MNW, der dækker sikkerhed, installation, specifikationer, betjening, statusindikatorer, fejlfinding og garantioplysninger. Lær, hvordan du beskytter dit udstyr mod strømafbrydelser.tages og stigninger.
Preview APC Back-UPS BX-seriens brugermanual: Installation, betjening og fejlfinding
Omfattende brugermanual til APC Back-UPS BX-serien (500VA til 2200VA) fra Schneider Electric, der dækker sikkerhedsinstruktioner, produktbeskrivelse, driftsfunktioner, installation, fejlfinding, service og garantioplysninger.
Preview APC Back-UPS BX-seriens brugermanual: Strøm- og overspændingsbeskyttelse til computere
Omfattende brugermanual til APC Back-UPS BX-serien (500VA til 2200VA). Lær om sikkerhed, installation, funktioner, specifikationer, statusindikatorer og fejlfinding for pålidelig strømbeskyttelse.
Preview APC Back-UPS BR1000G-IN / BR1500G-IN: Installations- og betjeningsmanual
Omfattende vejledning til installation og betjening af APC Back-UPS BR1000G-IN og BR1500G-IN Uninterruptible Power Supply (UPS), der dækker specifikationer, tilslutninger, funktioner, fejlfinding og service.
Preview APC Back-UPS Pro BR1000G installations- og betjeningsvejledning
Omfattende vejledning til installation og betjening af APC Back-UPS Pro BR1000G, der dækker opsætning, funktioner, sikkerhed, fejlfinding og specifikationer. Lær, hvordan du tilslutter udstyr, administrerer strømbesparelse og forstår advarsler.
Preview APC Back-UPS BN600G Brugermanual
Brugermanual til APC Back-UPS BN600G Uninterruptible Power Supply (UPS), der indeholder sikkerhedsoplysninger, specifikationer, installation, betjening, fejlfinding og garantioplysninger.