RAB Lighting X34

Brugermanual til RAB Lighting X34-seriens justerbare LED-projektør

Model: X34

Mærke: RAB Lighting

1. Introduktion

This manual provides detailed instructions for the installation, operation, and maintenance of the RAB Lighting X34 Series Adjustable LED Flood Light. Please read this manual thoroughly before installation and retain it for future reference.

Produkt overview

The RAB X34 Series is a professional-grade outdoor LED flood light designed for various lighting applications. It features field-selectable wattage and color temperature (CCT) settings, allowing customization of light output and ambiance. The robust design includes a die-cast aluminum housing, durable powder-coated finish, and IP65 protection for outdoor environments. An adjustable knuckle mount provides flexible positioning.

Nøglefunktioner

  • Valgbar Wattage & CCT: Adjust brightness and color temperature (3000K / 4000K / 5000K) to suit specific lighting requirements.
  • Justerbar montering: Integrated knuckle mount for precise beam positioning on walls, poles, or ceilings.
  • Holdbart udendørs design: IP65 rated, constructed with die-cast aluminum housing, powder-coated finish, and a UV-resistant lens for longevity in outdoor conditions.
  • Energieffektiv: High lumen output with low energy consumption, contributing to long-term cost savings and reduced maintenance.

2. Sikkerhedsoplysninger

ADVARSEL: Risiko for elektrisk stød. Afbryd strømmen før installation eller service. Installationen skal udføres af en kvalificeret elektriker i overensstemmelse med alle gældende nationale og lokale el-forskrifter.

  • Sørg for, at forsyningen voltage is correct for the fixture.
  • Do not handle live wires.
  • Brug sikkerhedsbriller og handsker under installationen.
  • Sørg for, at armaturet er sikkert monteret for at forhindre det i at falde ned.
  • Modificér ikke armaturet på nogen måde.
  • Hold brændbare materialer væk fra armaturet.
  • Operating temperature range: Consult product specifications for details.

3. Pakkens indhold

Kontroller, at alle komponenter er til stede, før installationen påbegyndes.

  • RAB X34 Series Adjustable LED Flood Light (1 unit)
  • Knuckle Mount (pre-attached)
  • LED Reflector (integrated)
  • Instruktionsmanual (dette dokument)

4. Installationsvejledning

Note: Installationen skal udføres af en kvalificeret elektriker.

4.1 Forinstallation

  1. Sluk for strømmen ved afbryderen, før installationen påbegyndes.
  2. Unpack the fixture and inspect for any damage.
  3. Identify the desired mounting location (wall, pole, or ceiling).

4.2 Montering af armaturet

The X34 Series flood light comes with a pre-attached knuckle mount for versatile installation.

  1. Securely attach the knuckle mount to the desired surface using appropriate hardware (not included). Ensure the mounting surface can support the weight of the fixture.
  2. Adjust the angle of the flood light by loosening the knuckle joint, positioning the light, and then tightening the joint firmly.
RAB X34 Series LED Flood Light with knuckle mount

Figur 1: RAB X34 Series LED Flood Light. This image shows the overall design of the flood light, including the LED array and the adjustable knuckle mount for installation.

4.3 Elektriske forbindelser

  1. Connect the fixture's wires to the main power supply wires according to local electrical codes (typically Black to Line, White to Neutral, Green/Bare Copper to Ground).
  2. Sørg for, at alle forbindelser er sikre og korrekt isolerede.

4.4 Kontrol efter installation

  1. Verify all connections are correct and secure.
  2. Gendan strømmen ved afbryderen.
  3. Test the fixture's operation.

5. Betjeningsvejledning

The RAB X34 Series flood light features field-selectable wattage and color temperature (CCT) settings. These settings are typically adjusted via switches located on the fixture, often behind a sealed cover.

5.1 Selecting Wattage

For at justere hvadtage (brightness) of the fixture:

  1. Afbryd strømmen: Always turn off power to the fixture at the circuit breaker before making any adjustments.
  2. Locate Switch: Identify the wattage selection switch on the fixture. This may be a rotary dial or a set of DIP switches.
  3. Vælg indstilling: Vælg det ønskede wattage setting according to your lighting needs. Refer to the product label or specific model documentation for available wattage muligheder.
  4. Gendan strøm: Once the selection is made, securely close any covers and restore power to the fixture.

5.2 Selecting Color Temperature (CCT)

To adjust the color temperature (light appearance) of the fixture:

  1. Afbryd strømmen: Always turn off power to the fixture at the circuit breaker before making any adjustments.
  2. Locate Switch: Identify the CCT selection switch on the fixture. This may be a rotary dial or a set of DIP switches.
  3. Vælg indstilling: Choose between 3000K (Warm White), 4000K (Neutral White), or 5000K (Cool White) as desired.
  4. Gendan strøm: Once the selection is made, securely close any covers and restore power to the fixture.

Note: The exact location and type of switches may vary by specific model. Consult the product's physical labeling or detailed specification sheet for precise instructions.

6. Vedligeholdelse

The RAB X34 Series LED Flood Light is designed for minimal maintenance. However, periodic checks and cleaning can ensure optimal performance and longevity.

  • Rensning: Periodically clean the lens and housing with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or lens. Ensure power is off before cleaning.
  • Inspektion: Inspicer årligt armaturet for tegn på skader, løse forbindelser eller slid. Kontroller, at monteringsbeslagene er tætte.
  • LED-levetid: The integrated LED array is designed for a long lifespan (up to 100,000 hours L70) and does not require bulb replacement.

7. Fejlfinding

If the fixture is not operating as expected, refer to the following common issues and solutions:

  • Lyset tænder ikke:
    • Check if power is supplied to the fixture at the circuit breaker.
    • Kontroller, at alle elektriske forbindelser er sikre og korrekte.
    • Ensure the fixture is not connected to a faulty switch or sensor.
  • Lyset flimrer eller dæmpes uventet:
    • Tjek for løse ledningsforbindelser.
    • Sørg for, at forsyningen voltage is stable and within the fixture's operating range.
    • If using a dimmer, ensure it is compatible with LED fixtures and properly installed.
  • Incorrect light output or color temperature:
    • Bekræft hvadtage and CCT selection switches are set to the desired positions.
    • Ensure the switches are fully engaged in their selected position.

If issues persist after following these steps, contact RAB Lighting customer support or a qualified electrician.

8. Specifikationer

The following specifications are typical for the RAB X34 Series. Specific values may vary by model variant.

FeatureDetalje
MærkeRAB belysning
ModelX34
MaterialeDie-cast Aluminum, Metal, Glass (Shade)
Color (Fixture)Bronze (as per current product) / White (available variant)
LyskildeIntegreret LED
Valgbar CCT3000K / 4000K / 5000K
Valgbar WattageYes (specific values depend on model)
Lumen outputUp to 14,000 lm (depending on model/wattage)
Lifespan (L70)Op til 100,000 timer
Ingress Protection (IP) RatingIP65 (støvtæt og beskyttet mod vandstråler)
MonteringstypeKnuckle Mount (Wall, Pole, Ceiling)
StrømkildeElektrisk med ledning
Indendørs/Udendørs brugOutdoor (also suitable for indoor commercial applications)
Produktdimensioner8.5 cm L x 6.5 cm B x 7.9 cm H
Varens vægtCirka 14 ounce
Særlige funktionerDimmable (with compatible dimmer)
Effektivitet147.1 lumen/watt
RAB X34 Series LED Flood Light dimensions

Figur 2: RAB X34 Series LED Flood Light Dimensional Drawing. This diagram provides key measurements for the fixture, including length, width, and height, useful for installation planning.

9. Garanti og support

RAB Lighting products are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official RAB Lighting webwebsted.

For technical assistance, troubleshooting, or replacement parts, please contact RAB Lighting customer support:

  • Webwebsted: www.rablighting.com
  • Telefon: Refer to RAB Lighting's official webhjemmeside for aktuelle kontaktnumre.
  • E-mail: Refer to RAB Lighting's official webwebsted for nuværende kontakt-e-mail.

Please have your product model number (X34) and purchase date available when contacting support.

Relaterede dokumenter - X34

Preview Installationsvejledning til ALED® feltjusterbare LED'er | RAB Lighting
Omfattende installationsvejledning til RAB Lightings ALED® feltjusterbare LED-armaturer (ALEDXXS, ALEDXS). Omfatter montering, ledningsføring, feltjustering og fejlfinding.
Preview Installationsvejledning til RAB SLIM feltjusterbar LED-belysning
Omfattende installationsvejledning til RAB Lightings SLIM-serie af feltjusterbare LED-armaturer, der dækker montering, elektriske tilslutninger, feltjusteringer for fotocelle, CCT, wattage, optisk vinkel og fejlfinding.
Preview RAB Lighting TOMO Wall Mount LED Fixture Installation Guide
Detailed installation instructions for RAB Lighting's TOMO Series wall mount LED fixtures. Covers wall mounting, continuous runs, field adjustments (CCT/Wattage), 0-10V dimming, and battery backup models with wiring diagrams and troubleshooting.
Preview RAB X34 Series Field-Adjustable LED Floodlight Installation Instructions
Comprehensive installation guide for RAB Lighting's X34 series field-adjustable LED floodlights, covering mounting, wiring, field adjustments (CCT, Power, Photocell), and maintenance.
Preview RAB Lighting BULLET® feltjusterbar LED-projektør installationsvejledning
Omfattende installations-, ledningsførings- og justeringsvejledning til RAB Lightings BULLET® feltjusterbare LED-projektører, inklusive sensorbetjening, montering og fejlfinding.
Preview Installationsvejledning til RAB feltjusterbar X22M LED-projektør
Omfattende installationsvejledning til RAB Field-Adjustable X22M LED-projektør, der dækker montering af slipfitter og trunnion, feltjusteringer for CCT og strøm, ændringer i strålevinkel, installation af fotocelle, udskiftning af linse og ledningsføring.