1. Introduktion
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your VEVOR Above Ground Pool Pump, Model HAP750. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Sikkerhedsoplysninger
Følg altid grundlæggende sikkerhedsforanstaltninger for at reducere risikoen for brand, elektrisk stød og personskade.
- Ensure the pump is installed by a qualified professional in accordance with all local and national electrical codes.
- Afbryd altid strømmen til pumpen, før du udfører vedligeholdelse eller service.
- Do not run the pump dry. Ensure the pump is filled with water before starting.
- Install the pump at least 10 feet (3 meters) from the inside walls of the pool.
- Use an extension cord only if absolutely necessary and ensure it is rated for outdoor use and the pump's power requirements.
- The pump is designed for use with permanently installed pools and spas. It should not be used with storage tanks.
- Ensure proper grounding. The pump incorporates grounding terminals to connect to ground lines for added security.
3. Produktet er slutview
The VEVOR Above Ground Pool Pump, Model HAP750, is a single-speed, 1HP pump designed for efficient water circulation and filtration in above-ground pools, hot tubs, and spas.
3.1 Nøglefunktioner
- 1 HK Premium kobbermotor: Operates at 120V / 60Hz with 3450 RPM, featuring an aluminum motor casing and built-in thermal protection for stable and efficient performance.
- Korrosionsbestandig fortykket skal: Constructed with a durable PP shell and integrated structure, ensuring leak-free and wear-resistant properties, even with disinfectant-treated water.
- Effektivt vandcirkulationssystem: Delivers a maximum water flow of 80 GPM and a maximum head lift of 36 ft (11 m) for rapid water circulation.
- Aftagelig filterkurv: Facilitates physical purification, compatible with a sand filter (not included). A transparent PVC cover allows easy monitoring for cleaning.
- Forbedret sikkerhed: Includes grounding terminals for connecting to ground lines.
- Alsidig anvendelse: Suitable for above-ground pools, hot tubs, spas, and irrigation systems. Not recommended for storage tanks.
3.2 Komponenter
The pump unit typically includes the motor, pump housing with a filter basket, and connection adapters.

This image displays the main pump unit, featuring the motor, pump housing with a clear lid for the filter basket, and several connection adapters for different hose sizes. The pump is black with a metallic motor housing.

This diagram highlights key components of the pump, including the water inlet, water outlet, pump body, detachable transparent lid, grounding terminal, strainer basket, ventilation fan, stable base, and drain plug. It illustrates the integrated corrosion-resistant casing.
4. Opsætning og installation
Korrekt installation er afgørende for pumpens ydeevne og levetid. Følg disse trin omhyggeligt.
4.1 Valg af sted
- Place the pump on a firm, level surface, ensuring it is at least 10 feet (3 meters) from the pool's edge.
- Ensure the location is well-ventilated and protected from direct sunlight and harsh weather conditions.
- The pump should be positioned below the water level of the pool to facilitate priming.
4.2 Elektrisk tilslutning
The VEVOR HAP750 pump operates on 120V / 60Hz. All electrical wiring must be performed by a licensed electrician and comply with local and national electrical codes.
- Sørg for, at strømforsyningen passer til pumpens volumentage krav (120V).
- Connect the pump to a dedicated, grounded circuit protected by a Ground Fault Circuit Interrupter (GFCI).
- Utilize the provided grounding terminals to ensure the pump is properly grounded.
This video demonstrates the process of connecting the power cord to a pool pump. It shows opening the junction box, connecting the live, neutral, and ground wires to their respective terminals, and then securing the junction box cover. While the video features a dual-speed pump, the wiring principles for a single-speed pump are similar for the power connection.
4.3 VVS-tilslutning
- Connect the pool's skimmer line (suction) to the pump's inlet.
- Connect the pump's outlet to the pool's return line (to the filter, then back to the pool).
- Use appropriate hose adapters (1-1/2" and 2" connection adapters are typically included) and hose clamps to ensure a watertight seal.
- Ensure all connections are tight to prevent air leaks, which can affect pump performance.

This image illustrates the pump with different hose adapters, emphasizing the flexibility in connecting to various plumbing setups. The adapters are crucial for ensuring a secure and leak-free connection between the pump and the pool's filtration system.
5. Betjeningsvejledning
5.1 Spædning af pumpen
Before starting the pump for the first time or after draining, it must be primed to ensure it is filled with water and free of air.
- Ensure all valves are open, allowing water to flow from the pool to the pump.
- Remove the transparent lid from the strainer basket.
- Fill the strainer basket housing completely with water.
- Replace the lid, ensuring it is securely tightened to create an airtight seal.
- Turn on the pump. It should begin to draw water from the pool.
- If the pump does not prime within a few minutes, turn it off, re-fill the strainer housing, and repeat the process.
5.2 Start af pumpen
Once primed, the pump is ready for operation.
- Sørg for, at alle VVS-forbindelser er sikre og lækagefri.
- Verify that the filter system (if applicable) is correctly set for filtration.
- Turn on the power to the pump. The pump will begin circulating water.
This video showcases a single-speed pool pump in operation, demonstrating the water circulation and the ease of installation of connection adapters. It highlights the pump's powerful performance and easy maintenance features, including the filter basket.
6. Vedligeholdelse
Regelmæssig vedligeholdelse sikrer optimal ydeevne og forlænger pumpens levetid.
6.1 Cleaning the Strainer Basket
The detachable filter basket should be checked and cleaned regularly, especially if water flow decreases or the transparent lid shows accumulated debris.
- Sluk pumpen og afbryd strømmen.
- Unscrew and remove the transparent lid.
- Løft si-kurven ud.
- Empty any debris and rinse the basket thoroughly with water.
- Undersøg O-ringen på låget for revner eller slid; udskift om nødvendigt.
- Place the clean basket back into the housing, ensuring it seats properly.
- Replace the lid and tighten securely.
- Genopfyld pumpen om nødvendigt, inden den genstartes.

Dette billede giver en klar view of the detachable strainer basket inside the pump housing, illustrating its function in capturing debris like leaves and small stones to prevent them from entering the pump or filter system.
6.2 Vinterisering
In colder climates, proper winterization is essential to prevent damage from freezing.
- Drain all water from the pump and plumbing lines.
- Remove the drain plug from the pump housing.
- Store the pump in a dry, protected area during the off-season.
7. Fejlfinding
Hvis du støder på problemer med din pumpe, kan du se følgende almindelige problemer og løsninger:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Pumpen starter ikke | No power; tripped GFCI; motor overload. | Check power supply; reset GFCI; allow motor to cool and reset thermal protection. |
| Pumpen kører, men der er ingen vandgennemstrømning | Pump not primed; air leak in suction line; clogged strainer basket. | Prime the pump; check all suction line connections for leaks; clean strainer basket. |
| Lav vandgennemstrømning | Clogged strainer basket; dirty filter; air leak. | Clean strainer basket; backwash/clean filter; check for air leaks. |
| Overdreven støj/vibration | Air leak; cavitation; loose mounting. | Check for air leaks; ensure adequate water supply to pump; tighten mounting bolts. |
8. Specifikationer
| Feature | Specifikation |
|---|---|
| Mærke | VEVOR |
| Modelnummer | HAP750 |
| Magt | 1 HK |
| Voltage | 120V / 60Hz |
| Roterende hastighed | 3450 RPM |
| Maksimal flowhastighed | 80 GPM |
| Maksimal hovedløft | 36 fod / 11 m |
| Materiale | Aluminium, polypropylen (PP) |
| Farve | Sort |
| Varens vægt | 22.93 pund |
| Produktdimensioner | 24.4 x 10 x 11.4 tommer |
| Ledningslængde | 35.4 tommer / 0.9 m |
| Compatible Sand Filter Size | 16-19 inches (not included) |
| Maksimal poolkapacitet | 27,000 gallons |

This graphic provides a visual overview of the pump's physical dimensions and a table summarizing its key technical specifications, including model number, voltage, power, rotating speed, max head lift, max water flow, cord length, compatible sand filter size, and maximum pool gallons.
9. Garanti og support
For warranty information or technical support, please refer to the product packaging or contact VEVOR customer service directly. Keep your purchase receipt for warranty claims.