ELKO EL-430

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Instruktionsmanual

Indledning

This manual provides detailed instructions for the proper use, setup, and maintenance of your ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer. Please read this manual thoroughly before using the device to ensure accurate readings and safe operation. This device is designed for professional and home use to measure blood pressure non-invasively.

Hvad er der i æsken

ELKO EL-430 Sphygmomanometer components and packaging

Image showing the ELKO EL-430 Sphygmomanometer packaging and its main components: the high precision gauge, BP bulb with valve, and special design cotton cuff.

Upon opening the package, verify that all components are present and undamaged. The standard package for the ELKO EL-430 includes:

Nøglefunktioner

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Image of the ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer, showing the large clock-face gauge, the black cotton cuff, and the inflation bulb.

Opsætning

Before taking a measurement, ensure the device is properly assembled and positioned. The EL-430 is a clock/desk type unit, designed for stable placement during use.

  1. Udpak komponenter: Carefully remove the sphygmomanometer, cuff, and inflation bulb from the packaging.
  2. Connect Cuff and Bulb: Ensure the cuff and inflation bulb are securely connected to the gauge via their respective tubes. The dual-tube bladder should be correctly attached.
  3. Placer enheden: Place the main gauge unit on a stable, flat surface, such as a desk or table, at approximately heart level. The integrated basket can be used to keep the cuff and bulb organized.
  4. Patientforberedelse: The patient should be seated comfortably with their arm resting on a flat surface, palm facing upwards. Ensure the arm is relaxed and at heart level. Avoid talking or moving during the measurement.

Operating Instructions: Measurement Procedures

Blood Pressure Measurement Procedures

Image illustrating the four key steps for blood pressure measurement: stethoscope placement, cuff inflation, listening for Korotkoff sounds, and controlled deflation.

Følg disse trin for nøjagtig blodtryksmåling:

  1. Cuff Placement and Stethoscope Positioning: Wrap the cuff firmly around the upper arm, ensuring it is snug but not too tight. The lower edge of the cuff should be about 1 inch (2-3 cm) above the elbow joint. Place the stethoscope head over the main artery (brachial artery), which is typically found on the inner side of the arm, underneath the artery mark of the cuff.
  2. Inflation: With the air release valve completely closed, press the inflation bulb repeatedly and continue pumping until the gauge reads a value 20-30 mmHg above your normal systolic blood pressure. If you do not know your normal systolic pressure, inflate to approximately 180-200 mmHg.
  3. Listening and Recording Systolic Pressure: Slowly open the air release valve to deflate the cuff at a rate of 2-3 mmHg per second. Listen carefully through the stethoscope. The first distinct, rhythmic sound you hear (Korotkoff sound) indicates the systolic pressure (the upper number). Note the reading on the gauge at this exact moment.
  4. Listening and Recording Diastolic Pressure: Continue to slowly deflate the cuff. The point at which the Korotkoff sounds completely disappear indicates the diastolisk tryk (the lower number). Note this reading on the gauge. If the sounds become muffled but do not disappear, the muffled sound point can be considered the diastolic pressure.

Forståelse af blodtryksaflæsninger

Blood Pressure Chart and Reading Precautions

Image displaying a blood pressure chart categorizing readings (Normal, Elevated, High Blood Pressure Stages 1 & 2, Hypertensive Crisis) and a list of conditions under which a reading should not be attempted.

Refer to the chart below for general blood pressure categories. Consult a healthcare professional for interpretation of your readings and personalized advice.

Blood Pressure Chart (mmHg)
BlodtrykskategoriSystolic (upper number)Diastolic (lower number)
NormalMindre end 120Mindre end 80
Forhøjet120 - 129Mindre end 80
Højt blodtryk (hypertension) Stage 1130 - 13980 - 89
Højt blodtryk (hypertension) Stage 2140 eller højere90 eller højere
Hypertensive Crisis (consult your doctor immediately)Higher Than 180Higher Than 120

DO NOT ATTEMPT A READING...

  1. Within 1 hour of food intake.
  2. Immediately after a tea, coffee, or a smoke.
  3. Within 20 minutes of taking a bath.
  4. While talking or moving your hand/fingers.
  5. When climate is very cold.
  6. When bladder is full or you feel like discharging urine.

Vedligeholdelse og pleje

Proper maintenance ensures the longevity and accuracy of your sphygmomanometer.

Fejlfinding

If you encounter issues with your ELKO EL-430, refer to the following common problems and solutions:

Specifikationer

SpecifikationDetalje
ModelnummerEL-430
Display TypeAnalog
Måleområde0 - 300 mmHg
Nøjagtighed+/- 3 mmHg
Manchet typeLarge Cotton Cuff with Velcro Fasteners
Inkluderede komponenterCuff, Gauge, Inflation Bulb with Valve
Varens vægt600 g
Produktmål (L x B x H)14L x 14W x 18Th Centimeters
FabrikantAnita Industries
OprindelseslandIndien
Dato først tilgængelig12. februar 2024

Garanti og support

For warranty information, technical support, or service inquiries regarding your ELKO EL-430 Sphygmomanometer, please contact the manufacturer directly.

Fabrikantens kontaktoplysninger:
Anita Industries
New Delhi, India
E-mail: info@elkoindia.com
Telefon: +91 9911129201

Please have your model number (EL-430) and date of purchase available when contacting support.

Relaterede dokumenter - EL-430

Preview ELKO RS16 TV/SAT/R-stikkontakt - instruktioner til udtjent levetid og bortskaffelsesvejledning
Omfattende vejledning til bortskaffelse og håndtering af ELKO RS16 TV/SAT/R-stikket efter endt levetid, inklusive produktoplysninger, komponentinformation og genbrugspotentiale i henhold til WEEE-direktivet.
Preview Brugervejledning til ELKO Smart Radiatortermostat
Omfattende brugervejledning til ELKO Smart Radiatortermostat, der dækker idriftsættelse, opsætning, konfiguration, brug, fejlfinding og tekniske specifikationer. Lær, hvordan du parrer, styrer og automatiserer dit varmesystem for komfort og energieffektivitet.
Preview ELKO Schuko stikkontakt med USB 3.0 A oplader - Installations- og brugervejledning
Comprehensive guide for the ELKO Schuko socket outlet featuring dual USB 3.0 A charging ports (Type A and Type C). Includes essential safety warnings, detailed technical specifications, installation steps, and usage instructions for electrical professionals and end-users.
Preview ELKO Plus / ELKO RS16 DCL vægstikkontakt installationsvejledning
Omfattende installationsvejledning til ELKO Plus og ELKO RS16 DCL vægstik. Indeholder vigtige sikkerhedsadvarsler, trinvise monteringsprocedurer, afmontering af dæksel, stiktilslutning, tekniske specifikationer og information om korrekt bortskaffelse. Vigtig for kvalificerede elektrikere.
Preview ELKO Smart Radiatortermostat Brugervejledning - Installation, konfiguration og betjening
Omfattende brugervejledning til ELKO Smart Radiatortermostat (EKO09765), der dækker installation, parring, konfiguration, daglig brug, planlægning, automatisering, fejlfinding og tekniske specifikationer.
Preview ELKO Smart Radiatortermostat Brugerhåndbog
Detaljeret brugerhåndbog til ELKO Smart Radiatortermostat, som dekker opsætning, brug, paring, automation, fejlsøgning og tekniske specifikationer for optimal hjemmeopvarmning.