Introduktion og overview
The ACCU-SCOPE EXC-350 Series microscope delivers advanced optical performance and versatility, designed for clinical, professional, and research applications. Featuring an enhanced LED illumination system and Infinity plan objectives, it provides bright, sharp, and crisp images. Its modular design supports various accessories for fluorescence, phase contrast, and darkfield applications.
Nøglefunktioner omfatter:
- Nem af Viewing: Newly designed WF10x/20mm focusable eyepieces and a binocular tube that rotates 180° to adjust observation height, enhancing ergonomics.
- Superb Optics: Infinity plan and Plan semi-APO objectives ensure high resolution, high contrast, and flat images across the entire 20mm field of view.
- Versatile & Modular Design: Allows for easy integration of filter sliders, phase contrast, and LED fluorescence options.

Hvad er der i æsken
Ved udpakning skal du kontrollere, at alle nedenstående komponenter er til stede:
- Microscope Body (EXC-350 Series)
- Eyepieces (WF 10x/20mm focusing eyepieces)
- Objectives (Infinity Plan Achromat 4x, 10x, 40xR, 100xR oil)
- Abbe Condenser (NA 1.25)
- Støvdæksel
- Immersionsolie
- Instruktionsmanual (dette dokument)
Opsætningsinstruktioner
Follow these steps to set up your EXC-350 microscope for initial use:
- Unpack the Microscope: Carefully remove all components from the packaging. Place the main microscope body on a stable, level surface away from direct sunlight and vibrations.
- Installer Viewhovedet: Gently place the trinocular viewing head onto the top of the microscope body. Secure it by tightening the set screw, if present, to prevent rotation.
- Indsæt okularer: Insert the WF 10x/20mm eyepieces into the eyepiece tubes of the viewing head. Ensure they are fully seated.
- Attach Objectives: Screw the Infinity Plan Achromat objectives (4x, 10x, 40xR, 100xR oil) into the nosepiece in ascending order of magnification (e.g., 4x, 10x, 40x, 100x). Ensure they are securely tightened.
- Tilslut strøm: Locate the power input port at the rear of the microscope. Connect the provided power cord to the microscope and then to a suitable 110v-240v AC power outlet.

Betjeningsvejledning
This section details the operation of your EXC-350 microscope for optimal viewing.
- Power On and Illumination: Turn on the microscope using the power switch. Adjust the 3-watt LED illumination intensity using the variable control knob to achieve comfortable brightness for your sample.
- Tilpasse Viewhovedet: The trinocular Siedentopf head can be inclined 30° and rotated 360°. The eyepoint height can be adjusted by 180° rotation of the binocular tube to accommodate different users.
- Set Interpupillary Distance: While looking through the eyepieces, adjust the interpupillary distance (50mm-75mm) until you see a single, clear circular field of view.
- Dioptrijustering: If your eyepieces have diopter adjustments, adjust them for individual eye focus. Typically, you focus with one eye (e.g., right eye) using the coarse and fine focus knobs, then adjust the diopter on the other eyepiece (e.g., left eye) until that eye is also in focus, without touching the main focus knobs.
- Place Specimen: Place your prepared slide onto the mechanical stage, fastgør den med s'ettage clips. Use the X-Y movement knobs to position the specimen directly over the condenser's light path.
- Select Objective: Rotate the rear-facing quintuple nosepiece to select the desired objective lens (e.g., 4x for initial scanning). Ensure the objective clicks firmly into place.
- Fokusering: Use the coaxial focusing system. Begin with the coarse focus knob to bring the specimen into approximate focus. Then, use the fine focus knob for precise focusing. The upper limit stop prevents accidental damage to slides and objectives.
- Condenser and Iris Diaphragm: Adjust the Abbe condenser (NA 1.25) using its rack and pinion mechanism to optimize illumination. Open or close the iris diaphragm to control contrast and resolution.
- Light Path Selector: Use the two-position light path selector to direct light: 100% to eyepieces for observation, or 80% to eyepieces and 20% to the camera port for imaging.


Opretholdelse
Korrekt vedligeholdelse sikrer mikroskopets levetid og optimale ydeevne.
- Rengøring af optik: Use only specialized lens cleaning paper and solution for objectives and eyepieces. For oil immersion objectives (100xR oil), clean off immersion oil immediately after use to prevent residue buildup.
- Støvbeskyttelse: Always cover the microscope with the provided dust cover when not in use to protect it from dust and debris.
- Generel rengøring: Wipe the microscope body with a soft, dry cloth. Avoid using harsh chemicals or abrasive cleaners.
- LED pære: The 3-watt LED bulb is rated for over 25,000 hours of continued use and typically does not require frequent replacement. If replacement is needed, consult a qualified technician or the manufacturer.
- Opbevaring: Opbevar mikroskopet et køligt, tørt sted, væk fra direkte sollys og ekstreme temperaturer.
Fejlfinding
Dette afsnit indeholder løsninger på almindelige problemer, du kan støde på.
- Ingen belysning:
- Check if the power cord is securely connected to both the microscope and the power outlet.
- Sørg for, at tænd/sluk-knappen er i "ON"-positionen.
- Verify the illumination intensity knob is turned up.
- Billedet er sløret eller ude af fokus:
- Juster grov- og finfokusknapperne.
- Ensure the objective lens is fully clicked into position.
- Check if the specimen slide is placed correctly on the stage.
- For 100x oil immersion objective, ensure immersion oil is applied correctly.
- Adjust interpupillary distance and diopter settings for your eyes.
- Felt af View is Dark or Uneven:
- Adjust the condenser height.
- Open the iris diaphragm.
- Ensure the light path selector is set correctly (e.g., 100% to eyepieces).
- Check if the objective lens is clean.
Specifikationer
| Feature | Detalje |
|---|---|
| Optisk system | Infinity optical system, f = 180mm |
| Viewhoved | Trinocular, Siedentopf type, Inclined 30°, rotatable 360°, Eyepoint height adjustable 180° |
| Interpupillær afstand | 50 mm-75 mm |
| Light Path Selector | 100% eyepieces, 80% eyepieces/20% camera port |
| Okularer | WF 10x/20mm focusing, lockable, accepts 26.5mm reticle |
| Næsestykke | Rear facing quintuple, ball bearing with positive click stops |
| Mål | Infinity Plan Achromat 4x, 10x, 40xR (spring-loaded), 100xR oil (spring-loaded) |
| Stage | Rackless Mechanical Stage, 150mm x 110mm, X-Y movement 76mm X 50mm |
| Kondensator | Abbe condenser NA 1.25 (with slots for sliders), rack and pinion with iris diaphragm |
| Stå | Støbt legeret aluminium |
| Belysning | 3-watt LED with variable intensity control, rated for over 25,000 hours |
| Strømforsyning | Universal 110v-240v |
| Fokuseringssystem | Coaxial with adjustable tension control and upper limit stop, all metal gears, brass fine focus gear |
| Microscope Dimensions (LWH) | 294 mm x 199 mm x 397 mm (11.57 x 199 x 15.63 tommer) |
| Fysisk vægt | 24 lbs (10.89 kg) |
| Maksimal forstørrelse | 1000x |
| Materiale | Aluminiumslegering |
| Dato først tilgængelig | 24. januar 2024 |
Garanti og support
The EXC-350 Clinical Professional Compound Microscope comes with a comprehensive warranty and is backed by Accu-Scope's commitment to quality.
- Garanti: A 5-year limited warranty covers parts, labor, and electronic components. The LED bulb has a 1-year warranty.
- Certificeringer: The product is certified to ISO 9001:2018 and ISO 14001:2018 standards, and is UL approved.
- Kundesupport: For technical assistance, service, or warranty claims, please contact Accu-Scope customer support. You can find more information and contact details on the Accu-Scope Store on Amazon.





