1. Introduktion
This manual provides essential information for the safe and efficient operation of your FOTING 1.5HP Submersible Sump Pump (Model FT-Q1100B121M). Please read these instructions thoroughly before installation and use to ensure proper function and longevity of the product.
2. Sikkerhedsoplysninger
WARNING: DO NOT RUN DRY.
The pump is designed for submersible use only. Operating the pump without being fully submerged in water can cause severe damage to the motor and void the warranty. Always ensure the pump is adequately submerged before connecting to power.
Always disconnect the power supply before performing any maintenance, cleaning, or when the pump is not in use.
Ensure the power cord and plug are in good condition. Do not use if damaged. Avoid moving the pump by pulling the power cord.
This pump is equipped with a built-in automatic thermal overload protector to prevent motor burnout during dry running or overheating. If the pump stops unexpectedly, disconnect power, allow it to cool, and check for obstructions or low water levels before restarting.
3. Produktfunktioner
- Effektiv dræning: 1.5HP oil-free PSC motor, capable of draining up to 5000 GPH (82.32 GPM) at a 5ft discharge lift, with a maximum vertical lift of 33ft.
- Automatic & Manual Operation: Features a float switch with a buckle design for continuous operation (when uplifted) or automatic ON/OFF based on water level.
- Bred anvendelighed: Drains water down to 1.77 inches from the surface and handles solids up to 1.38 inches. Suitable for pools, basements, pits, ponds, and other flooded areas.
- Durable & Quiet: Fully corrosion-resistant thermoplastic construction with thermal overload protection. Operates quietly, typically below 60 dB.
- Lang strømledning: Equipped with a 16ft power cord for extended reach and safety.
4. Pakkens indhold
- 1 x FOTING 1.5HP Submersible Sump Pump
- 1 x 16 FT Power Cord (attached)
- 1 x GHT 1-1/2" Multi-Hose Adapter
- 1 x brugsanvisning
5. Opsætning og installation
- Attach Discharge Hose: Select the appropriate hose connector size on the multi-hose adapter (26mm, G1", 36mm, or G1-1/2") to match your discharge hose. Screw the adapter onto the pump's discharge outlet. Secure your discharge hose to the adapter.
- Placer pumpen: Place the pump on a level and solid foundation in the area to be drained. Ensure the exhaust hole is not blocked by debris.
- Adjust Float Switch: The float switch controls the automatic operation. You can adjust the activation and deactivation water levels by moving the float switch clip along the pump body. Ensure the float switch can move freely without obstruction.

Image: The FOTING sump pump with the blue multi-hose adapter screwed onto the top discharge port. The adapter allows for various hose sizes.

Image: A diagram illustrating the multi-hose adapter with various connection points for different hose diameters (GHT 1-1/2", GHT 1", Φ1-1/2", Φ1-1/4", Φ1").

Image: The FOTING sump pump partially submerged in water, showing the float switch floating on the surface. The pump is ready for operation.

Image: A visual guide demonstrating the automatic and manual modes of the float switch. In automatic mode, the float rises and falls with water level. In manual mode, the float is secured upright for continuous pumping.
6. Betjeningsvejledning
Automatisk tilstand:
In automatic mode, the pump will turn ON when the water level rises above approximately 19 inches and turn OFF when the water level drops to approximately 8.6 inches or below. To activate automatic mode, ensure the float switch is free to move with the water level.
Manuel tilstand:
For continuous pumping, or when the water level is too low to activate the float switch automatically, you can engage manual mode. Secure the float switch in an upright position using the buckle design on the pump body. The pump will operate continuously until unplugged. Forsigtighed: Monitor the pump closely in manual mode to prevent dry running.

Image: A hand clipping the float switch to the side of the pump body, demonstrating how to set it for continuous manual operation.
Indledende opstart:
Once the pump is positioned and the hose is connected, plug the power cord into a grounded electrical outlet. The pump will activate according to the selected mode and water level.

Image: A three-step visual guide showing the process: 1. Select appropriate pipe, 2. Plug in and place pump in water, 3. Wait for water to drain.
7. Ansøgninger
The FOTING 1.5HP Sump Pump is suitable for various water drainage tasks, including:
- Draining swimming pools and hot tubs.
- Removing water from flooded basements and cellars.
- Emptying garden ponds and window wells.
- Transferring water from rain barrels.
- General utility pumping of clean and slightly dirty water.

Image: A collage showing six different scenarios where the FOTING sump pump can be used, such as draining a garden pond, swimming pool, hot tub, for parking irrigation, in a basement, and in flooded areas.
8. Vedligeholdelse
- Rensning: Regularly inspect the pump's intake screen for debris and clear any blockages to maintain optimal performance.
- Opbevaring: When not in use, especially during freezing temperatures, drain all water from the pump and store it in a dry, protected area.
- Inspektion: Periodically check the power cord for any signs of damage. Do not use the pump if the cord is frayed or cut.
9. Fejlfinding
- Pumpen starter ikke:
- Check if the pump is plugged into a working power outlet.
- Ensure the float switch is in the correct position for automatic or manual operation and is not obstructed.
- Verify that the water level is sufficient to activate the float switch in automatic mode.
- Check for thermal overload protection activation. Disconnect power, allow the pump to cool, and inspect for blockages.
- Reduced Flow/No Water Output:
- Inspect the intake screen and impeller for debris or blockages.
- Ensure the discharge hose is not kinked or obstructed.
- Verify that the pump is fully submerged and not running dry.
10. Specifikationer
| Specifikation | Værdi |
|---|---|
| Mærke | FOTING |
| Modelnummer | FT-Q1100B121M |
| Strømkilde | AC |
| Hestekræfter | 1.5 HK |
| Voltage | 115 volt |
| Wattage | 1100 watt |
| Frekvens | 60 Hz |
| Maksimal flowhastighed | 5000 GPH (84 gallon pr. minut) |
| Maksimal løftehøjde | 33 fod |
| Minimum Suction Level | 1.77 inches from surface |
| Max partikelstørrelse | 1.38 tommer |
| Ledningslængde | 16 fod |
| Materiale | Termoplastisk |
| Varens vægt | 13.68 pund |
| Pakkedimensioner | 16.65 x 9.45 x 7.09 tommer |
11. Officielle produktvideoer
FOTING Sump Pump - Easy Setup and Demonstration
Video: A detailed demonstration of the FOTING sump pump's easy setup and operation, showcasing its functionality in various scenarios. (Creator: DIY for Home and Life)
1.5 HP Sump Pump Submersible with Float Switch, 5000 GPH
Video: This video highlights the features and performance of the 1.5 HP FOTING sump pump, demonstrating its 5000 GPH capacity and float switch operation. (Creator: Blue Fins)
1.5HP automatic sump pump for basement and pool
Video: A brief demonstration of the FOTING 1.5HP automatic sump pump in action, suitable for basements and pools. (Creator: Blue Fins)
12. Garanti og support
FOTING is committed to customer satisfaction. This sump pump features a mechanical seal design for efficiency and energy. For any questions or concerns, please do not hesitate to contact FOTING customer support.
The product is designed for reliability and long-lasting performance, featuring an oil-free PSC motor and 1100W power output.