Sanuvox LMPRGXJ65

Sanuvox LMPRGXJ65 UV Lamp Instruktionsmanual

For Models: P900-GX, R1500-GX, S100-GX, SR Max, SR+ UV Air Systems

1. Introduktion

This manual provides essential information for the proper installation, operation, and maintenance of your OEM Sanuvox LMPRGXJ65 UV Lamp. This UV lamp is a critical component designed to enhance indoor air quality by neutralizing airborne pathogens and allergens in compatible Sanuvox air purification systems. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Produktet er slutview

The Sanuvox LMPRGXJ65 UV Lamp is an OEM replacement part specifically engineered for Sanuvox air purification systems. It utilizes advanced UV-C technology to provide continuous air purification, contributing to a healthier indoor environment.

Sanuvox LMPRGXJ65 UV Lamp

Figure 2.1: The Sanuvox LMPRGXJ65 UV Lamp, a U-shaped bulb with white bases and electrical pins.

Nøglefunktioner:

3. Sikkerhedsoplysninger

ADVARSEL: UV-C radiation is harmful to skin and eyes. Never look directly at an illuminated UV lamp. Always ensure the air purification system is powered off and disconnected from the power source before attempting any installation, maintenance, or inspection of the UV lamp.

4. Opsætning og installation

The LMPRGXJ65 UV lamp is designed for easy replacement in compatible Sanuvox air purification systems. Follow these steps carefully:

  1. Sluk: Ensure the Sanuvox air purification system is completely powered off and unplugged from the electrical outlet before beginning installation. This is crucial for safety.
  2. Adgang til Lamp Rum: Refer to your specific Sanuvox air purifier model's manual for instructions on how to safely access the UV lamp compartment. This typically involves opening a panel or cover.
  3. Fjern gammel Lamp: Carefully grasp the base of the old UV lamp and gently pull it straight out from its socket. Avoid touching the glass part of the lamp.
  4. Installer ny Lamp: Align the pins on the base of the new LMPRGXJ65 UV lamp with the corresponding slots in the socket. Gently push the lamp firmly into place until it is securely seated. Do not force it.
  5. Sikkert rum: Luk og fastgør l'enamp compartment cover or panel according to your system's instructions.
  6. Gendan strøm: Plug the air purification system back into the electrical outlet and power it on. Verify that the new UV lamp illuminates and the system operates correctly.
Diagram showing UV lamp installation in an air system

Figure 4.1: Illustrative diagram of a UV 'J' Lamp installed within an air purification system, showing dirty air entering, passing through a turbulator and past the UV lamp, and clean air exiting.

5. Driftsprincipper

The Sanuvox LMPRGXJ65 UV Lamp operates by emitting germicidal UV-C light. As air passes through your Sanuvox air purification system, airborne microorganisms such as bacteria, viruses, mold spores, and allergens are exposed to this high-intensity UV-C radiation. The UV-C light penetrates the cell walls of these contaminants, disrupting their DNA and rendering them inactive or unable to reproduce, thereby purifying the air.

Lamp is designed for continuous operation within the compatible Sanuvox systems to maintain optimal indoor air quality.

6. Vedligeholdelse

The LMPRGXJ65 UV lamp is engineered for longevity, but like all UV lamps, its germicidal effectiveness diminishes over time. Regular replacement is crucial to ensure continuous optimal performance of your air purification system.

7. Fejlfinding

If you encounter issues with your Sanuvox LMPRGXJ65 UV Lamp or the air purification system after installation, refer to the following common troubleshooting steps:

ProblemMulig årsagLøsning
Lamp does not illuminate after installation.
  • Systemet er ikke tændt.
  • Lamp ikke sidder ordentligt.
  • Defekt lamp.
  • Systemfejl.
  • Ensure the air purification system is plugged in and powered on.
  • Turn off power, unplug, and re-seat the lamp fast.
  • Hvis en ny lamp, it might be defective. Contact support for replacement.
  • Consult your Sanuvox system's manual for system-specific troubleshooting or contact Sanuvox support.
Reduced air purification effectiveness.
  • Lamp nærmer sig livets ende.
  • Beskidt lamp overflade.
  • System filters are clogged.
  • Udskift UV lamp if it's been in use for approximately one year.
  • Rengør lamp surface (ensure power is off).
  • Check and replace air filters in your Sanuvox system as per its manual.

For issues not covered here, please refer to the comprehensive manual for your specific Sanuvox air purification system or contact Sanuvox customer support.

8. Specifikationer

AttributDetalje
MærkeSanuvox
ModelnummerLMPRGXJ65
Kompatible modellerSanuvox P900-GX, R1500-GX, S100-GX, SR Max, SR+ UV Air Systems
LyskildetypeUV-C (Ultraviolet Germicidal Irradiation)
Indendørs/Udendørs brugIndendørs
Varens vægt9.5 ounce
Pakkedimensioner13.9 x 5.79 x 2.91 tommer
UPC645637610361
Speciel funktionLangvarig

9. Garanti og support

Specific warranty information for the Sanuvox LMPRGXJ65 UV Lamp is typically provided with the original air purification system or can be obtained directly from Sanuvox or your authorized dealer. Please retain your proof of purchase for warranty claims.

For technical support, replacement parts, or further inquiries, please contact Sanuvox customer service or visit their official website. Contact details are usually found in the main air purification system's manual or on the manufacturer's webwebsted.

Relaterede dokumenter - LMPRGXJ65

Preview Sanuvox S300FX-GX HEPA/UV luftrenser: Installations-, vedligeholdelses- og betjeningsvejledning
Omfattende vejledning til installation, betjening og vedligeholdelse af Sanuvox S300FX-GX HEPA/UV luftrenser til hele huset. Indeholder sikkerheds-, tekniske data-, betjenings-, vedligeholdelses- og garantioplysninger.
Preview Sanuvair S1000 luftrensningsenhed med filtre - brugermanual til erhvervsmodel
Denne manual indeholder instruktioner til installation, betjening og vedligeholdelse af Sanuvair S1000 luftrensningsenhed med filtre, en kommerciel model designet til store rum. Den indeholder sikkerhedsforanstaltninger, komponentbeskrivelser, trinvise installationsvejledninger og fejlfindingstips.
Preview Sanuvox SABER MAGNET 24V UV Coil Cleaner Instruction Manual
Comprehensive instruction manual for the Sanuvox SABER MAGNET 24V residential UV coil cleaner, covering installation, operation, maintenance, troubleshooting, and warranty information.
Preview Sanuvox ASEPT.1X MAX fast UV-overfladeenhed - brugsanvisning
Omfattende brugsanvisning til Sanuvox ASEPT.1X MAX fast UV-overfladeenhed. Dækker installation, betjening, vedligeholdelse, sikkerhed og fejlfinding i forbindelse med UVC-overfladerensning.
Preview Brugsanvisning til Sanuvox BIO-WALL™ UV-luftdesinfektionssystem
Denne brugsanvisning giver omfattende vejledning til Sanuvox BIO-WALL™ UV-luftdesinfektionssystemet. Lær om installation, drift, vedligeholdelse og fejlfinding for effektiv luftrensning i kommercielle og industrielle miljøer.
Preview Sanuvair S1000 CRO luftrensningsenhed med filtre - Brugsanvisning til erhvervsmodel
Brugsanvisning til Sanuvair S1000 CRO kommerciel model luftrensningsenhed med filtre. Dækker sikkerhedsinstruktioner, komponenter, opsætning, betjening, vedligeholdelse, fejlfinding og garantioplysninger.