GOLDCHAMP GC-4070L-1

GOLDCHAMP GC-4070L-1 Capacitor Tester User Manual

Model: GC-4070L-1 | Brand: GOLDCHAMP

1. Introduktion

GOLDCHAMP GC-4070L-1 is a professional digital multimeter designed for precise measurement of capacitance, inductance, and resistance. It also features a transistor hFE test function. This device is equipped with a manual range selection, a clear LCD with backlight, and an auto power-off function for energy efficiency. It is an essential tool for home use, educational settings, electrical repair, and electronics engineering.

GOLDCHAMP GC-4070L-1 Capacitor Tester with test leads, screwdriver, and 9V battery.

Figur 1: GOLDCHAMP GC-4070L-1 Capacitor Tester and included accessories.

2. Sikkerhedsoplysninger

To ensure safe operation and to avoid damage to the meter, please read this manual carefully before use. Always adhere to the following safety precautions:

3. Produktet er slutview og komponenter

The GC-4070L-1 meter consists of a main unit, test leads, a screwdriver, and a 9V battery. Familiarize yourself with the meter's layout:

Front view of the GOLDCHAMP GC-4070L-1 showing Power On button, Back Light button, Function Switch, and Probe Jacks.

Figur 2: Front panel layout of the GC-4070L-1, highlighting key controls and jacks.

Inkluderede varer:

4. Opsætning

4.1 Batteriinstallation

The GC-4070L-1 requires one 9V battery for operation. Follow these steps to install or replace the battery:

  1. Sørg for, at måleren er slukket.
  2. Find batterirummet på bagsiden af ​​måleren.
  3. Brug den medfølgende skruetrækker til at løsne skruen, der fastgør batteridækslet.
  4. Fjern batteridækslet.
  5. Connect the 9V battery to the battery clips, observing correct polarity.
  6. Place the battery inside the compartment and replace the cover, securing it with the screw.
Bag view of the GOLDCHAMP GC-4070L-1 showing the battery compartment and stand, with an inset image of the 9V battery being installed.

Figur 3: Battery compartment and installation of the 9V battery.

4.2 Tilslutning af testledninger

Tilslut testledningerne til de relevante indgangsstik:

5. Betjeningsvejledning

5.1 Tænd/sluk

Tryk på det røde MAGT button to turn the meter on. Press it again to turn the meter off.

5.2 Funktionsvalg

Rotate the central function switch to select the desired measurement mode (e.g., Capacitance 'C', Inductance 'L', Resistance 'Ω', or hFE).

5.3 Baggrundsbelysningsfunktion

Tryk på den blå Baggrundslys button to illuminate the LCD display. This feature is useful in dimly lit environments. Press it again to turn off the backlight.

Close-up of the GOLDCHAMP GC-4070L-1 display with backlight activated, illustrating improved visibility in low-light conditions.

Figur 4: The backlight feature enhances display visibility.

5.4 Automatisk slukning

The meter is designed to automatically power off after approximately 10 minutes of inactivity to conserve battery life. To reactivate, press the MAGT knap.

5.5 Måleprocedurer

Always ensure the component or circuit is de-energized and discharged before connecting the test leads.

5.5.1 Capacitance Measurement (C)

  1. Rotate the function switch to the desired capacitance range (e.g., 2000pF, 20nF, 200nF, 2uF, 20uF, 200uF).
  2. Tilslut den røde testledning til COM/LC+ Jack og den sorte testledning til LC- stik.
  3. Connect the test leads across the capacitor to be measured.
  4. Aflæs kapacitansværdien på LCD-displayet.

5.5.2 Inductance Measurement (L)

  1. Rotate the function switch to the desired inductance range (e.g., 20mH, 200mH, 2H, 20H).
  2. Tilslut den røde testledning til COM/LC+ Jack og den sorte testledning til LC- stik.
  3. Connect the test leads across the inductor to be measured.
  4. Read the inductance value on the LCD display.

5.5.3 Modstandsmåling (Ω)

  1. Rotate the function switch to the desired resistance range (e.g., 20Ω, 200Ω, 2KΩ, 20KΩ, 200KΩ, 2MΩ, 20MΩ, 200MΩ, 2000MΩ).
  2. Tilslut den røde testledning til Ω Jack og den sorte testledning til COM/LC+ stik.
  3. Connect the test leads across the resistor or circuit to be measured.
  4. Aflæs modstandsværdien på LCD-displayet.

5.5.4 hFE Test (Transistor Test)

  1. Drej funktionskontakten til hFE position.
  2. Identificer om transistoren er NPN eller PNP.
  3. Insert the transistor's emitter (E), base (B), and collector (C) leads into the corresponding holes in the hFE socket on the meter.
  4. Read the hFE value (DC current gain) on the LCD display.
GOLDCHAMP GC-4070L-1 in use, demonstrating its capabilities for resistance, capacitance, inductance, and hFE testing, with backlight and auto shut down features.

Figur 5: The GC-4070L-1 performing a measurement.

6. Vedligeholdelse

6.1 Rengøring

Tør målerens hus af med enamp en klud og et mildt rengøringsmiddel. Brug ikke slibemidler eller opløsningsmidler. Sørg for, at måleren er helt tør før brug.

6.2 Udskiftning af batteri

Refer to Section 4.1 for detailed instructions on replacing the 9V battery.

6.3 Opbevaring

Hvis måleren ikke bruges i længere tid, skal batteriet fjernes for at forhindre lækage og skader. Opbevar måleren et køligt og tørt sted, væk fra direkte sollys og ekstreme temperaturer.

7. Fejlfinding

If you encounter issues with your GC-4070L-1, refer to the table below for common problems and their solutions:

ProblemMulig årsagLøsning
Intet display eller svagt displayLavt eller dødt batteri; Forkert batteriinstallationReplace the 9V battery; Check battery polarity.
Forkerte aflæsningerWrong function/range selected; Test leads not properly connected; Component not fully dischargedSelect the correct function and range; Ensure test leads are securely connected; Discharge capacitors before measurement.
Måleren tænder ikkeBattery issue; Power button malfunctionCheck/replace battery; If problem persists, contact support.

8. Specifikationer

The following are the technical specifications for the GOLDCHAMP GC-4070L-1:

FeatureSpecifikation
kapacitans Range2000pF, 20nF, 200nF, 2uF, 20uF, 200uF
Induktansområde20mH, 200mH, 2H, 20H
Modstandsområde20Ω, 200Ω, 2KΩ, 20KΩ, 200KΩ, 2MΩ, 20MΩ, 200MΩ, 2000MΩ
hFE testYes (for NPN/PNP transistors)
ViseLarge LCD, 1999 counts
BaggrundsbelysningJa
Automatisk slukCirka 10 minutters inaktivitet
Strømkilde1 x 9V batteri (inkluderet)
Operation Voltage9 volt (DC)
Dimensioner6.02 x 4.45 x 1.81 tommer
Vægt9.59 ounce

9. Garanti og support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact GOLDCHAMP customer service directly. Contact details can typically be found on the manufacturer's official webhjemmeside eller gennem din forhandler.

Relaterede dokumenter - GC-4070L-1

Preview GOLDCHAMP DT-4070L 3 1/2 digitalt LCR multimeter brugermanual
Brugsanvisning til GOLDCHAMP DT-4070L 3 1/2 digitalt LCR-multimeter. Dækker introduktion, panellayout, specifikationer for modstands-, kapacitans-, induktans- og transistor hFE-test, brugsanvisning og vedligeholdelse.
Preview GOLDCHAMP Brugsanvisning til digitalt anemometer - Vejledning til måling af vindhastighed
Omfattende brugermanual til GOLDCHAMP Digitalt anemometer. Lær hvordan du måler vindhastighed og luftmængde, og forstår dets funktioner og specifikationer til HVAC, drone og udendørs brug.
Preview ANENG SZ08 Digitalt Multimeter Brugsanvisning
Betjeningsvejledning og tekniske specifikationer for ANENG SZ08 digitalt multimeter, der dækker sikkerhedsforanstaltninger, målemetoder, elektriske specifikationer, vedligeholdelse og batteriudskiftning.
Preview Habotest HT122 digitalt RMS multimeter brugermanual
Brugermanual til Habotest HT122 digitalt RMS multimeter, med detaljerede sikkerhedsinstruktioner, produktbeskrivelse, målefunktioner (NCV, vol.tagf.eks. modstand, frekvens, kapacitans, kontinuitet, diode, fasesekvens), vedligeholdelse og batteriudskiftning. Funktionerne omfatter True RMS og smarte testfunktioner.
Preview ANENG 622A Intelligent Digital Multimeter Brugervejledning
This user manual provides comprehensive instructions for operating the ANENG 622A Intelligent Digital Multimeter. It covers safety precautions, detailed descriptions of the device and its LCD display, technical specifications for various measurement functions (AC/DC voltage and current, resistance, capacitance, frequency, temperature, diode test, continuity), operating guidelines, and procedures for battery and fuse replacement.