1. Introduktion
This manual provides essential information for the installation, operation, and maintenance of your First Alert SMICO100-AC Combination Smoke and Carbon Monoxide Alarm. This device is designed to provide early warning of smoke and carbon monoxide presence in your home. It features interconnectivity for synchronized alarming and a battery backup for continuous protection during power outages.

2. Nøglefunktioner
- Precision Detection Technology: Advanced sensing technology designed to reduce nuisance alarms from cooking while providing early warning of fire.
- Sammenkoblingsfunktion: When one alarm sounds, all compatible interconnected alarms will activate, ensuring widespread alert throughout your home.
- Hardwire with Battery Backup: Operates on household electrical current with a 9V battery backup for continued protection during power failures.
- Hurtig tilslutningsstik: Facilitates easy installation without the need for rewiring existing compatible setups.
- Test/Stilhed knap: Allows for convenient testing of alarm functions and silencing of nuisance alarms.

3. Installation
3.1 Sikkerhedsforanstaltninger
- Turn off power to the circuit before installation.
- Installation must comply with all local electrical codes.
- Consult a licensed electrician if you are unsure about wiring procedures.
3.2 Montering
- Remove the old alarm unit from its mounting bracket.
- Attach the new mounting bracket (included) to the electrical box on the ceiling or wall. Ensure the bracket is securely fastened.
- Connect the wiring harness: Black to Black (Line), White to White (Neutral), and Orange to Orange (Interconnect). If your existing wiring uses different colors for interconnect, refer to the alarm's specific wiring diagram.
- Plug the wiring harness into the back of the SMICO100-AC alarm unit.
- Insert the 9V battery into the battery compartment. Ensure the battery is properly seated.
- Align the alarm unit with the mounting bracket and twist clockwise until it locks securely into place.
- Gendan strømmen til kredsløbet.

4. Betjeningsvejledning
4.1 Indledende opstart
Upon restoring power, the alarm will perform a self-test. A green LED indicator should illuminate, signifying normal operation. If the alarm chirps or sounds continuously, refer to the troubleshooting section.
4.2 Test/Stilhed-knap
- Test: Press and hold the Test/Silence button for a few seconds. The alarm will sound a loud, pulsating alarm pattern (3 beeps for smoke, 4 beeps for CO). This confirms the electronic circuitry, horn, and battery are working. Test weekly.
- Silencing Nuisance Alarms: In case of a non-emergency alarm (e.g., from cooking smoke), press the Test/Silence button to temporarily silence the alarm for several minutes. The alarm will automatically reset after the silence period if smoke or CO levels return to normal.
4.3 LED-indikatorer
- Grøn LED: Flashes once every 60 seconds, indicating the alarm is receiving AC power and operating correctly.
- Gul LED: Indicates a fault or malfunction. Refer to the troubleshooting section.
- Rød LED: Flashes rapidly during an alarm event (smoke or CO detected).
5. Placeringsretningslinjer
For optimal protection, install combination smoke and carbon monoxide alarms on every level of your home, including basements, and inside every bedroom. Additionally, place alarms in hallways outside sleeping areas.


6. Vedligeholdelse
6.1 Regelmæssig testning
Test your alarm weekly by pressing the Test/Silence button. This ensures the unit is functioning correctly.

6.2 Udskiftning af batteri
Replace the 9V battery at least once a year, or immediately when the alarm chirps every minute (indicating a low battery). To replace, open the battery drawer, remove the old battery, insert a new 9V alkaline battery, and close the drawer.
6.3 Rengøring
Clean your alarm monthly to remove dust and debris. Use a soft brush attachment on your vacuum cleaner to gently vacuum the alarm's vents. Do not use water, cleaners, or solvents.
6.4 Udskiftning af enhed
Alarms have a limited lifespan. Replace your First Alert SMICO100-AC alarm at least every 10 years from the date of manufacture. The manufacture date is printed on the back of the alarm.

7. Fejlfinding
| Problem | Tegn | Løsning |
|---|---|---|
| Alarm chirps every minute | Lavt batteri | Udskift 9V-batteriet. |
| Alarmen bipper hvert 30.-40. sekund | Fejlfunktion | Clean the alarm. If chirping persists, replace the unit. |
| Generelle alarmer | Smoke from cooking/steam | Press Test/Silence button. Ensure proper placement away from cooking areas. |
| Alarmen lyder ikke under testen | Enheden fungerer ikke | Check power connection and battery. Replace unit if problem persists. |
8. Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | Første alarm |
| Modelnummer | SMICO100-AC |
| Strømkilde | Corded Electric with 9V Battery Backup |
| Sensortype | Ionization (Smoke), Electrochemical (CO) |
| Produktdimensioner | 5.5" D x 2" B x 5.5" H |
| Varens vægt | 0.56 pund (9 ounce) |
| Driftsfugtighed | 10-95% RF |
| Inkluderede komponenter | Easy Adapter Plug, 9V Battery |
9. Garanti og support
For warranty information, technical support, or to obtain a user's manual, please refer to the documentation included with your product or visit the official First Alert website. Regular maintenance and testing are crucial for the proper functioning of your alarm.





