Waveshare WA8TAI-8CH

Waveshare Industrial 8-kanals analog optagelsesmodul (WA8TAI-8CH) Brugermanual

This manual provides detailed instructions for the setup, operation, and maintenance of the Waveshare Industrial 8-Channel Analog Acquisition Module, Model WA8TAI-8CH.

1. Introduktion

The Waveshare Industrial 8-Channel Analog Acquisition Module (Model WA8TAI-8CH) is a high-precision device designed for industrial data acquisition. It supports 8 channels of 12-bit analog input, capable of acquiring both voltage (0-10V) and current (0-20mA or 4-20mA) signals. This module utilizes the Modbus RTU protocol over an RS485 interface, making it suitable for integration into various industrial control systems. Key features include a wide DC 7-36V power supply range, multiple isolation protections, and a robust rail-mount design for easy installation.

Two Waveshare Industrial 8-Channel Analog Acquisition Modules side-by-side, highlighting their compact industrial design.

Figure 1.1: Waveshare Industrial 8-Channel Analog Acquisition Modules.

2. Pakkens indhold

Bekræft, at alle nedenstående varer er inkluderet i din pakke:

  • Modbus RTU Analog Input 8CH (B) Module x1
  • Power Supply Terminal Adapter x1
  • Jumper Cap (10 PCS) x1
Contents of the Waveshare module package, including the module, power adapter, and jumper caps.

Figur 2.1: Pakkens indhold.

3. Funktioner

The WA8TAI-8CH module incorporates several features designed for reliable and accurate industrial data acquisition:

  • 8-Channel 12-Bit High-Precision Acquisition: Supports simultaneous acquisition of 8 analog signals with 12-bit resolution, offering high accuracy.
  • Voltage and Current Input: Capable of acquiring both voltage (0-10V) and current (0-20mA or 4-20mA) signals, configurable via jumpers.
  • Modbus RTU Protocol: Communicates using the standard Modbus RTU protocol over RS485, allowing for configurable device addresses (1-255).
  • Wide Voltage Strømforsyning: Operates with a DC 7-36V power input, providing flexibility for various industrial power sources.
  • Multiple Isolation Protections: Features onboard unibody power supply isolation, magnetic isolation, resettable fuse, and Transient Voltage Suppressor (TVS) for enhanced reliability and anti-interference in industrial environments.
  • Komponenter af høj kvalitet: Utilizes high-precision resistors and zero-drift operational amplifiers for accurate data acquisition.
  • Stabil drift: Includes a built-in oversampling digital filtering algorithm and an onboard watchdog to ensure stable output without system crashes.
  • Rail-Mount Design: Designed for easy installation on a 35mm standard DIN rail, supporting stacking for multiple modules.
  • Statusindikatorer: Three LEDs (RXD, TXD, STATUS) provide visual feedback on MCU status and signal transmission.
Diagram showing key features of the Waveshare module, including 12-bit high-precision, voltage and current acquisition, DC 7-36V wide voltage, Modbus RTU protocol, and multiple isolation protection.

Figure 3.1: Features at a Glance.

Indre view of the module highlighting industrial-grade isolated protection components such as voltage regulator, power isolator, magnetic isolation, TVS, fuse, zero-drift operational amplifier, MCU, and ESD protection.

Figure 3.2: Industrial Grade Isolated Protection.

4. Specifikationer

ParameterVærdi
ModelModbus RTU Analog Input 8CH (B)
KommunikationsgrænsefladeRS485
Baud rate4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000
Default Communication Format9600, N, 8, 1
Modbus-protokolStandard Modbus RTU protocol
StrømforsyningDC 7-36V
Sampling Nøjagtighed12-bit resolution, accuracy <3%
Dataopdateringshastighed25 Hz
InputtilstandSupports single-ended/differential input, voltage and current simultaneous acquisition
Standardtilstand8-ch voltage mode, 0-10V
Rækkevidde0-10V / 2-10V, 0-20mA / 4-20mA
Nuværende Sampling-modstand499Ω
Dimensioner (L x B x H)121.0 x 72.0 x 35.0 mm (ca.)
Vægt5.9 ounce (ca.)
Table of specifications for the Modbus RTU Analog Input 8CH and 8CH (B) modules, detailing communication interface, baud rate, Modbus protocol, power supply, sampling accuracy, data update rate, input mode, default mode, range, and current samplange modstand.

Figure 4.1: Module Specifications.

5. Interface overview

The module features clearly labeled terminals and LED indicators for easy connection and status monitoring.

5.1. Terminaldefinitioner

  • 7~36V: DC power input (positive).
  • GND: Strøm jord.
  • AI1+ to AI8+: Positive terminals for analog input channels 1 to 8.
  • AI1- to AI8-: Negative terminals for analog input channels 1 to 8.
  • A+: RS485 differential signal positive terminal.
  • B-: RS485 differential signal negative terminal.

5.2. LED-indikatorer

  • RXD: Receive Data indicator. Flashes when data is being received via RS485.
  • TXD: Transmit Data indicator. Flashes when data is being transmitted via RS485.
  • STATUS: Working Status indicator. Indicates the module's operational state.
Front view of the Waveshare Industrial 8-Channel Analog Acquisition Module, showing terminal blocks for power, analog inputs, RS485, and LED indicators.

Figure 5.1: Module Front View with Terminals and Indicators.

Diagram illustrating the interface introduction of the module, showing 7-36V DC power supply, analog input, RS485 interface, and the RX, TX, and Working Status indicators.

Figure 5.2: Interface Introduction and Indicators.

6. Opsætning og konfiguration

6.1. Tilslutning af strømforsyning

Connect a DC power source within the 7-36V range to the '7~36V' and 'GND' terminals. Ensure correct polarity to prevent damage to the module. The module features anti-reverse protection.

6.2. RS485 Communication Connection

Connect the RS485 A+ terminal of the module to the A+ terminal of your RS485 master device (e.g., PC, PLC) and the B- terminal of the module to the B- terminal of your master device. Ensure proper wiring for half-duplex communication.

Diagram showing the wide voltage power supply connection (DC 7-36V) and the isolated RS485 interface, highlighting anti-reverse protection, ESD protection, and power supply and signal dual isolation.

Figure 6.1: Power Supply and RS485 Interface.

6.3. Analog Input Mode Selection

The module supports both voltage and current acquisition. The specific input range (e.g., 0-10V, 0-20mA, 4-20mA) is configurable via internal jumpers. Refer to the manufacturer's wiki or detailed product documentation for precise jumper settings for each channel. Incorrect jumper settings may lead to inaccurate readings or module damage.

Diagram showing how to configure voltage and current acquisition ranges using jumpers, with examples for 0-5V, 1-5V, 0-20mA, and 4-20mA inputs.

Figur 6.2: Voltage/Current Acquisition Range Configuration.

6.4. Analog Input Connection

Connect your analog sensors to the AIx+ and AIx- terminals for each channel. For voltage inputs, connect the sensor's positive output to AIx+ and negative/ground to AIx-. For current inputs, connect the sensor in series with the AIx+ and AIx- terminals, ensuring the current flows correctly through the module's internal samplange modstand.

6.5. Modbus RTU Configuration

The module's device address (1-255), baud rate, and parity settings are configured via Modbus commands from the master device. The default communication format is 9600, N, 8, 1. Consult the Waveshare product wiki for detailed Modbus register maps and command examples til konfiguration.

7. Betjening af modulet

Once powered and configured, the module operates as a Modbus RTU slave device. The master device sends Modbus commands to read the analog input values from the module's registers. The module provides 12-bit digital values corresponding to the analog input signals.

7.1. bindtage Acquisition (0-10V)

I bindtage mode, the module measures input voltages from 0V to 10V. The 12-bit resolution provides 4096 discrete levels across this range. The acquired digital value can be scaled by the master device to represent the actual voltage.

7.2. Current Acquisition (0-20mA / 4-20mA)

In current mode, the module measures input currents from 0mA to 20mA or 4mA to 20mA, depending on the jumper configuration. Similar to voltage mode, the 12-bit digital output needs to be scaled by the master device to obtain the actual current value.

Diagram showing two versions of the Modbus RTU Analog Input 8CH module, one supporting 0-5V/1-5V and 0-20mA/4-20mA, and the other (Model B) supporting 0-10V/2-10V and 0-20mA/4-20mA.

Figure 7.1: Module Version Options and Supported Ranges.

8. Tilslutningsdiagrammer

Below are typical connection diagrams for integrating the module into an industrial system.

Comprehensive connection diagram showing the Waveshare module connected to a 7-36V DC power supply, various sensors (pressure, temperature, flow), an RS485 bus, and a PC or PLC. Also illustrates multi-device cascading and voltage/current input wiring.

Figure 8.1: Typical Connection Diagram for Sensors and Modbus Network.

9. Rail-Mount and Stacking Installation

The module is designed for easy installation on a standard 35mm DIN rail. It also supports stacking multiple modules together to create a compact and organized system.

9.1. Rail-Mount Support

Attach the module to a 35mm standard guide rail using its integrated rail-mount buckle. Ensure it clicks securely into place.

9.2. Stablingsinstallation

For stacking, remove the rail-mount buckle from the outer module. Then, align and assemble the two modules together using screws to secure them.

Diagram illustrating rail-mount support on a 35mm standard guide rail and instructions for stacking multiple modules together using screws after removing the rail-mount buckle.

Figure 9.1: Rail-Mount and Stacking Installation.

10. Fejlfinding

Hvis du støder på problemer med dit modul, skal du se følgende almindelige fejlfindingstrin:

  • Ingen strøm: Verify that the DC 7-36V power supply is correctly connected and providing the specified voltage. Check the power supply terminal adapter and wiring for any loose connections or damage.
  • Ingen RS485-kommunikation:
    • Ensure RS485 A+ and B- terminals are correctly wired to the master device.
    • Check that the module's device address is unique on the bus and matches the address used by the master.
    • Verify that the baud rate, parity, data bits, and stop bits are consistent between the module and the master device.
    • Observe the RXD and TXD LEDs; they should flash during communication. If not, check wiring and master device configuration.
    • For long RS485 bus lines, ensure proper termination resistors (120 Ohm) are used at both ends of the bus.
  • Inaccurate Analog Readings:
    • Confirm that the internal jumpers for voltage/current input mode and range are set correctly for your sensor type.
    • Check the sensor's output and wiring for any faults or interference.
    • Ensure the sensor is powered correctly and operating within its specified range.
    • While the module offers high precision, external calibration of the sensor or scaling in the master device may be required for critical applications.
  • Module Malfunction After Power Disconnection: Ensure that power connections are stable and secure. Avoid abrupt disconnections, especially under load, as this can potentially stress components.

11. Vedligeholdelse

To ensure the longevity and optimal performance of your Waveshare Industrial 8-Channel Analog Acquisition Module, follow these maintenance guidelines:

  • Rensning: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquid cleaners or solvents.
  • Miljø: Operate the module within its specified environmental conditions (temperature, humidity). Avoid exposure to extreme temperatures, direct sunlight, or corrosive environments.
  • Forbindelser: Kontrollér regelmæssigt alle ledningsforbindelser for at sikre, at de er fastgjorte og fri for korrosion.
  • Ventilation: Ensure adequate airflow around the module, especially if multiple modules are stacked, to prevent overheating.

12. Garanti og support

For warranty information, technical support, or service inquiries, please contact your Waveshare product reseller or visit the official Waveshare website. Keep your purchase receipt or proof of purchase for warranty claims.

Relaterede dokumenter - WA8TAI-8CH

Preview Module d'Entrée Analogique Modbus RTU 8 Canaux par Waveshare
Ce dokument teknik présente le modul d'entrée analogique 8 canaux Modbus RTU de Waveshare, conçu pour l'acquisition de données de tension et de courant dans les systèmes d'automatisation industrielle. De detaljerede specifikationer, teknikker, forbindelsesmetoder, logiske tests og modbus-kommunikationsprotokoller.
Preview Waveshare Modbus RTU analog udgang 8CH - Teknisk vejledning og protokol
Omfattende teknisk guide til Waveshare Modbus RTU Analog Output 8CH-modulet. Dækker hardwarebeskrivelse, versionssammenligning, hardwaretilslutning, softwaretest med SSCOM og Modbus Poll, demoprocedurer for Raspberry Pi, STM32, Arduino og PLC samt en detaljeret Modbus-udviklingsprotokol V2.
Preview Waveshare Modbus RTU analog indgang 8CH - Brugermanual og teknisk specifikation
Omfattende guide til Waveshare Modbus RTU Analog Input 8CH-modulet, der dækker hardwarebeskrivelse, versionssammenligning, konfiguration, softwaretest med SSCOM og Modbus Poll samt udviklingsprotokoller til Raspberry Pi, STM32 og Arduino.
Preview Modbus RTU-relæ: Brugermanual og teknisk vejledning
Omfattende guide til Modbus RTU-relæet, der dækker sikkerhedsinstruktioner, hardwaretilslutning, softwareopsætning med SSCOM og Modbus Poll samt detaljerede kommandoprotokoller til forskellige operationer. Inkluderer f.eks.ampLektioner til Raspberry Pi, STM32, Arduino og PLC-integration.
Preview Modbus RTU Relæ 32CH Brugermanual og Teknisk Guide
Omfattende brugermanual og teknisk vejledning til Modbus RTU Relay 32CH. Dækker sikkerhed, hardware, softwareintegration (Raspberry Pi, STM32, Arduino, PLC) og Modbus RTU-kommandoprotokoller til industriel automation.
Preview USB TIL 8CH TTL Industriel UART til TTL Konverter - Product Overview og guide
Detailed information on the USB TO 8CH TTL industrial UART to TTL converter, including features, specifications, driver installation, and communication operation. Features CH348L chip, robust protection circuits, and 8-channel TTL output.