SHAHE ANC-30

SHAHE Digital Torque Adapter ANC-30 (0.9-30N.m) Instruction Manual

1. Introduktion

This manual provides detailed instructions for the proper use, setup, operation, and maintenance of your SHAHE Digital Torque Adapter, model ANC-30. This high-precision digital torque adapter is designed for accurate torque measurement in various applications, including automotive, bicycle, motorcycle, and general home repairs. Please read this manual thoroughly before operating the device to ensure safe and efficient use.

SHAHE Digital Torque Adapter ANC-30 with 1/2 inch drive and two smaller adapters (3/8 inch and 1/4 inch)

Image 1.1: The SHAHE Digital Torque Adapter ANC-30, shown with its primary 1/2-inch drive and two included adapter sizes (3/8-inch and 1/4-inch) for versatile use.

2. Sikkerhedsoplysninger

Overhold altid følgende sikkerhedsforanstaltninger for at forhindre personskade eller beskadigelse af enheden:

  • Do not exceed the maximum torque capacity of 30 N.m. Over-torquing can damage the adapter and the fastener.
  • Ensure the adapter is securely attached to your wrench and the socket/fastener before applying torque.
  • Keep the device clean and dry. Avoid exposure to extreme temperatures or corrosive environments.
  • Forsøg ikke at skille enheden ad eller ændre den. Reparationer bør kun udføres af kvalificeret personale.
  • Opbevar enheden i dens beskyttende etui, når den ikke er i brug, for at forhindre skader.
  • Opbevar batterier utilgængeligt for børn.

3. Produktet er slutview

3.1 Medfølgende komponenter

The SHAHE Digital Torque Adapter ANC-30 package includes:

  • 1 x SHAHE Digital Torque Adapter ANC-30
  • 1 x Brugsanvisning (dette dokument)
  • 2 x AAA batterier
  • 1 x opbevaringskasse
  • 1 x 1/2" to 3/8" Adapter
  • 1 x 1/2" to 1/4" Adapter
SHAHE Digital Torque Adapter ANC-30 and accessories neatly arranged in a black protective storage case

Image 3.1: The SHAHE Digital Torque Adapter ANC-30, its instruction manual, and the included adapters stored within its protective carrying case.

3.2 Enhedskomponenter og kontroller

Familiarize yourself with the various parts and controls of the digital torque adapter:

Diagram of SHAHE Digital Torque Adapter ANC-30 showing labeled parts: Switch, Display screen, Buzzer (rear), Indicator light, '+' button, '-' button, Save button (M), Setting button (U/S), Switch button (P/C)

Image 3.2: Labeled diagram of the SHAHE Digital Torque Adapter ANC-30, indicating the display screen, control buttons, indicator light, and buzzer location.

  • Skærm: Shows torque readings, units, and mode.
  • '+'-knap: Øger værdier eller navigerer i menuer.
  • '-' Knap: Reducerer værdier eller navigerer i menuer.
  • 'M' (Save) Button: Used for mode selection and saving settings.
  • 'U/S' (Setting) Button: Used for unit selection and system settings.
  • 'P/C' (Switch) Button: Power on/off and peak/track mode selection.
  • Indikatorlys: Provides visual feedback, especially for alarm functions.
  • Buzzer (rear): Provides audible feedback, especially for alarm functions.
  • Switch (Drive): The 1/2-inch square drive for attaching sockets or adapters.

4. Opsætning

4.1 Batteriinstallation

The device requires two AAA batteries (included). To install:

  1. Find batteridækslet på bagsiden af ​​enheden.
  2. Åbn låget.
  3. Isæt de to AAA-batterier, og sørg for at polerne vender korrekt (+/-).
  4. Luk batterirummets dæksel forsvarligt.

4.2 Attaching Adapters and Sockets

The SHAHE Digital Torque Adapter ANC-30 features a 1/2-inch drive. Use the included adapters to fit 3/8-inch and 1/4-inch drive sockets.

SHAHE Digital Torque Adapter ANC-30 with 1/2 inch drive, alongside 1/2 to 3/8 inch adapter and 1/2 to 1/4 inch adapter

Image 4.1: The digital torque adapter with its native 1/2-inch drive, shown next to the 3/8-inch and 1/4-inch drive adapters for connecting various socket sizes.

  1. Select the appropriate adapter (1/2\" to 3/8\" or 1/2\" to 1/4\") if your socket is not 1/2-inch.
  2. Firmly attach the adapter to the 1/2-inch drive of the digital torque adapter.
  3. Attach your desired socket to the adapter or directly to the 1/2-inch drive.
  4. Sørg for, at alle forbindelser er sikre inden brug.

5. Betjeningsvejledning

5.1 Tænd/sluk

  • Tænd: Press the 'P/C' button to turn on the device. The display will light up.
  • Sluk: Press and hold the 'P/C' button for a few seconds to turn off the device. The device will also automatically power off after 5 minutes of inactivity to conserve battery life.

5.2 Valg af enhed

The adapter supports four torque units: N.m, ft.lb, in.lb, and kgf.cm.

Four display screens of the SHAHE Digital Torque Adapter ANC-30 showing different units: lbf.ft, lbf.in, kgf.cm, and N.m

Billede 5.1: Eks.amples of the digital display showing torque values in lbf.ft, lbf.in, kgf.cm, and N.m, demonstrating the unit conversion capability.

  • With the device powered on, press the 'U/S' button repeatedly to cycle through the available units (N.m, ft.lb, in.lb, kgf.cm).
  • Select the desired unit for your measurement.

5.3 Måletilstande

The device offers three measurement modes: Real-time (Track), Peak, and Preset.

  • Realtidstilstand (spor): Displays the current torque being applied. This is useful for monitoring torque as it is being applied. To select, press the 'M' button until \"track\" appears on the display.
  • Toptilstand: Captures and displays the maximum torque value reached during the application. This is useful for verifying the highest torque applied. To select, press the 'M' button until \"peak\" appears on the display.
  • Forudindstillet tilstand: Allows you to set a target torque value. The device will provide an audible and visual alarm when the target torque is approached and reached. To select, press the 'M' button until \"preset\" appears on the display.

5.4 Setting Target Torque (Preset Mode)

When in Preset Mode:

  1. Enter Preset Mode by pressing the 'M' button.
  2. Press the 'U/S' button to enter the setting interface. The target torque value will flash.
  3. Use the '+' and '-' buttons to adjust the target torque value.
  4. Press the 'U/S' button again to confirm the setting.

5.5 Applying Torque and Alarm Function

Once the mode and unit are selected, apply torque to the fastener. The device will display the torque value in real-time (Track mode) or capture the peak (Peak mode).

SHAHE Digital Torque Adapter ANC-30 displaying a torque value with a red indicator light illuminated and a sound wave icon, indicating an alarm

Image 5.2: The digital torque adapter showing its alarm function in action, with a red indicator light and an audible alert when the preset torque value is reached.

  • Hørbar og visuel alarm: In Preset Mode, as you approach the target torque, the device will emit a continuous beep and the indicator light will flash. When the target torque is reached, the beep will become continuous and the red indicator light will stay solid.
  • Stop applying torque immediately when the alarm indicates the target has been reached to avoid over-torquing.

6. Vedligeholdelse og pleje

  • Rensning: Tør enheden af ​​med en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Opbevaring: Store the digital torque adapter in its protective case in a dry, cool place, away from direct sunlight and extreme temperatures.
  • Udskiftning af batteri: Replace batteries when the low battery indicator appears on the display. Remove batteries if the device will not be used for an extended period to prevent leakage.
  • Kalibrering: Til professionelle anvendelser, der kræver certificeret nøjagtighed, anbefales periodisk kalibrering foretaget af et kvalificeret servicecenter.

7. Fejlfinding

ProblemMulig årsagLøsning
Enheden tænder ikke.Døde eller forkert installerede batterier.Kontroller batteripolariteten. Udskift med nye AAA-batterier.
Upræcise aflæsninger.Device not properly zeroed or requires calibration.Ensure the device is at rest before powering on. If issues persist, consider professional calibration.
Alarm not functioning.Not in Preset Mode or alarm volume is too low (if adjustable).Ensure the device is in Preset Mode. Check manual for alarm volume adjustment (if applicable).
Skærmen er svag eller flimrer.Lav batteristrøm.Udskift batterierne.

8. Specifikationer

ModelANC-30
Måleområde0.9 - 30 N.m
Minimum Division Value0.01 Nm
Nøjagtighed±2% (Clockwise), ±2.5% (Counter-clockwise)
Drevstørrelse1/2 inch (includes 3/8 inch and 1/4 inch adapters)
MåletilstandeReal-time (Track), Peak, Preset
EnhederN.m, ft.lb, in.lb, kgf.cm
MaterialeLegeret stål
Strømkilde2 x AAA alkaliske batterier (inkluderet)
Automatisk slukEfter 5 minutters inaktivitet
Varens vægt0.45 kg (15.8 ounce)
FabrikantWenzhou Sanhe Measuring Instrument Co.,LTD

9. Garanti og support

SHAHE products are manufactured to high-quality standards. For warranty information or technical support, please refer to the contact details provided with your purchase documentation or visit the official SHAHE webwebsted. Gem venligst din købsbevis i tilfælde af garantikrav.

Relaterede dokumenter - ANC-30

Preview 数显扭矩起子使用说明书 - Shahe
Shahe数显扭矩起子用户手册,详细介绍了产品的功能特点、规格型号、抽敿眯参说明、维修保养及随机附件。适用于精密制造行业小扭矩紧固件装配狩和悉
Preview SHAHE IP67 Digital Caliper Brugervejledning
Brugermanual til SHAHE IP67 digital skydelære, med detaljerede oplysninger om funktioner, tekniske specifikationer, sikkerhedsforanstaltninger, instruktioner og fejlfinding. Dækker modellerne 150 mm, 200 mm og 300 mm.
Preview SHAHE Digitalt Hældningsmåler (Model 5341-90/5341-90B) - Brugermanual
Brugermanual til SHAHE Digital Inclinometer (aluminiumsramme). Funktioner omfatter relativ/absolut måling, vinkel/hældningskonvertering, datalagring, genopladeligt batteri og stærke magneter. Detaljer om tekniske parametre, betjeningsvejledning og anvendelser.
Preview Specifikation og installationsvejledning til SHAHE ekstern lineal
Tekniske specifikationer, sikkerhedsforanstaltninger og installationsvejledning til SHAHE digitale eksterne linealer, inklusive modeller som 5403-serien. Funktioner omfatter måleområder, nøjagtighed og displayfunktioner.
Preview SHAHE Shore D hårdhedstestere og stativer - Tekniske specifikationer
Detaljerede tekniske data og funktioner for SHAHE Shore D hårdhedsmålere (LXD-D, LX-D-1, LX-D-2) og deres kompatible stativer (LAC-J, LD-J). Indeholder specifikationer som rækkevidde, dimensioner og applikationsnoter.
Preview SHAHE Shore A & C hårdhedstestere - Tekniske specifikationer og funktioner
Detaljeret overview af SHAHEs LXD-A, LX-A-1, LX-A-2, LXD-C, LX-C-1 og LX-C-2 Shore A og Shore C hårdhedsmålere, inklusive tekniske data og funktioner til forskellige materialetestningsapplikationer.