1. Introduktion og overview
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your TOTAL Gasoline Generator, model TP155001. This powerful 5000W generator, equipped with a 13HP engine and a 25L fuel tank, is designed to provide reliable power for various applications, from home backup to commercial use.
Key features include AVR (Automatic Voltage Regulation) for stable power output, overload protection for safety, and a robust 4-stroke engine. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
2. Sikkerhedsoplysninger
ADVARSEL: Manglende overholdelse af disse sikkerhedsinstruktioner kan resultere i alvorlig personskade eller død.
- Kuliltefare: Generators produce carbon monoxide, a colorless, odorless, poisonous gas. Operate generators outdoors only, far away from windows, doors, and vents. Never operate indoors, in a garage, or in any enclosed space.
- Brandfare: Gasoline is highly flammable. Always refuel in a well-ventilated area with the engine off and cool. Do not smoke or allow open flames near the generator. Store fuel in approved containers.
- Fare for elektrisk stød: Never operate the generator in wet conditions. Ensure proper grounding. Do not touch the generator or connected cords with wet hands. Use only approved extension cords that are rated for outdoor use and the generator's power output.
- Varme overflader: Motoren og lyddæmperen bliver meget varme under drift og forbliver varme i et stykke tid efter slukning. Undgå kontakt for at forhindre forbrændinger.
- Bevægelige dele: Hold hænder, fødder, hår og tøj væk fra bevægelige dele for at forhindre skader.
- Børn og kæledyr: Hold altid børn og kæledyr væk fra generatoren.
- Overbelastningsbeskyttelse: Do not overload the generator. Overloading can damage the generator and connected devices. The generator is equipped with overload protection.
3. Produktfunktioner
The TOTAL TP155001 Gasoline Generator is engineered with features designed for performance, durability, and user convenience:
- Høj effekt: Provides a maximum output of 5500W (5.5 KW) and a rated output of 5000W, suitable for a wide range of tools and appliances.
- Kraftfuld motor: Equipped with a robust 13HP, 4-stroke gasoline engine for reliable and consistent power.
- Automatisk voltage Forordning (AVR): Sikrer stabil volumentage output, protecting sensitive electronics from power fluctuations.
- Overbelastningsbeskyttelse: Built-in circuit breaker automatically shuts off power if the generator is overloaded, preventing damage to the unit and connected devices.
- Stor brændstoftank: Features a 25-liter fuel tank for extended run times.
- Elektrisk start: For convenient and easy starting.
- Holdbar konstruktion: Housed in a sturdy metal frame with wheels and handles for portability.
- 100% Copper Coil Alternator: Ensures efficient power generation and durability.

Image: The TOTAL TP155001 generator showcasing its 5.0kW output, 4-stroke engine, gasoline fuel type, electric start, and 100% copper coil alternator.
4. Komponenter og kontroller
Familiarize yourself with the main components and control panel of your generator:

Billede: En samlet view of the TOTAL TP155001 Gasoline Generator, showing its robust frame, fuel tank, engine, and control panel.

Image: A close-up of the control panel on the TOTAL TP155001 generator, detailing the engine switch, voltmeter, AC 220-240V-50Hz outlets, and circuit breaker.
- Brændstoftank: Located on top of the generator, with a capacity of 25 liters.
- Brændstofdæksel: Til påfyldning af brændstoftanken.
- Motorafbryder: Controls the engine's ignition (ON/OFF).
- Voltmeter: Viser output voltage af generatoren.
- AC Outlets (220-240V, 50Hz): Receptacles for connecting electrical devices.
- Afbryder: Protects the generator from overload by tripping when current exceeds safe limits.
- Oil Sensor/Low Oil Shutoff: Automatically stops the engine if oil level is too low.
- Chokerhåndtag: Bruges til at starte en kold motor.
- Recoil Starter (Pull Start): For manual starting.
- Electric Start Button/Key Switch: For electric starting (requires battery).
- Batteri: 12V 9Ah battery for electric start.
- Luftfilter: Filters air entering the engine.
- Lyddæmper: Reducerer motorstøj og dirigerer udstødningsgasserne.
- Wheels and Handles: For nem transport.
5. Opsætning
Before first use, or after extended storage, proper setup is crucial.
5.1 Udpakning og montering
- Tag forsigtigt generatoren ud af emballagen.
- Undersøg for eventuelle forsendelsesskader. Kontakt din forhandler med det samme, hvis der konstateres skader.
- Assemble the wheels and handles if they are not pre-installed, following the instructions in the separate assembly guide (if provided).
5.2 Påfyldning af motorolie
The generator is shipped without engine oil. You must add the correct amount and type of oil before starting.
- Placer generatoren på en plan overflade.
- Locate the oil fill cap/dipstick (usually near the engine).
- Remove the cap/dipstick and slowly add recommended engine oil (e.g., SAE 10W-30) until it reaches the upper mark on the dipstick. Do not overfill.
- Sæt oliepåfyldningsdækslet/målepinden sikkert på igen.
5.3 Påfyldning af brændstof
WARNING: Use fresh, unleaded gasoline only. Do not use E85 or a gasoline/oil mixture. Do not overfill.
- Sørg for, at motoren er slukket og afkølet.
- Flyt generatoren til et godt ventileret udendørs område.
- Skru tankdækslet af.
- Carefully pour gasoline into the fuel tank, using a funnel if necessary, up to the fill limit (do not fill to the very top of the neck).
- Sæt tankdækslet sikkert på igen. Tør straks spildt brændstof op.
5.4 Connecting the Battery (for Electric Start)
If the battery is not pre-connected, connect the positive (+) terminal (red cable) to the positive (+) battery post and the negative (-) terminal (black cable) to the negative (-) battery post. Ensure connections are tight.
5.5 Jordforbindelse af generatoren
For safety, the generator must be properly grounded. Connect a heavy-gauge copper wire from the generator's grounding terminal to an external grounding rod driven into the earth.
6. Betjeningsvejledning
6.1 Tjekliste før start
- Kontroller motoroliestanden.
- Tjek brændstofniveauet.
- Sørg for, at alle elektriske apparater er frakoblet generatorens stikkontakter.
- Verify the generator is on a level surface and in a well-ventilated outdoor area.
- Bekræft korrekt jording.
6.2 Start af motoren (elektrisk start)
- Drej brændstofventilen til "ON"-positionen.
- Flyt chokerhåndtaget til "CHOKE"-positionen (hvis motoren er kold).
- Drej motorkontakten til "ON"-positionen.
- Press and hold the electric start button (or turn the key) until the engine starts. Do not crank for more than 5 seconds at a time. If it doesn't start, wait 10 seconds before trying again.
- Når motoren starter, skal du langsomt flytte chokerhåndtaget til "RUN"-positionen.
6.3 Start af motoren (rekylstart)
- Follow steps 1-3 from Electric Start.
- Grasp the recoil starter handle firmly and pull slowly until resistance is felt, then pull quickly and smoothly. Repeat until the engine starts.
- Når motoren starter, skal du langsomt flytte chokerhåndtaget til "RUN"-positionen.
6.4 Tilslutning af elektriske belastninger
Allow the engine to run for a few minutes to warm up before connecting any electrical devices.
- Ensure the circuit breaker on the generator is in the "ON" position.
- Plug in your electrical devices or extension cords into the AC outlets.
- Do not exceed the generator's rated wattage (5000W continuous, 5500W max).
6.5 Nedlukning af generatoren
- Afbryd alle elektriske belastninger fra generatorens stikkontakter.
- Lad motoren køre i et par minutter uden belastning for at køle af.
- Drej motorkontakten til "OFF"-positionen.
- Drej brændstofventilen til "OFF"-positionen.
7. Vedligeholdelse
Regular maintenance is essential for optimal performance and longevity of your generator. Always perform maintenance with the engine off and cool.
7.1 Vedligeholdelsesplan
| Punkt | Før hver brug | Hver 25. time / månedligt | Hver 100 timer / Årligt |
|---|---|---|---|
| Tjek motoroliestanden | ✓ | ||
| Skift motorolie | First 20 hours, then as needed | ✓ | |
| Ren luftfilter | ✓ | ||
| Inspicer tændrøret | ✓ | ||
| Inspicer brændstoffilteret | ✓ | ||
| Check Battery Terminals | ✓ |
7.2 Opbevaring
Til langtidsopbevaring (mere end 30 dage):
- Tøm brændstoftanken og karburatoren, eller tilsæt en brændstofstabilisator.
- Skift motorolien.
- Fjern tændrøret og hæld en lille mængde motorolie i cylinderen. Træk i rekylstarteren et par gange for at fordele olien, og sæt derefter tændrøret i igen.
- Clean the generator exterior.
- Store in a clean, dry, well-ventilated area, away from direct sunlight and heat sources.
8. Fejlfinding
Dette afsnit indeholder løsninger på almindelige driftsproblemer. Kontakt kvalificeret servicepersonale ved problemer, der ikke er nævnt her.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Motoren vil ikke starte | Intet brændstof Lavt olieniveau Motorafbryder OFF Chokeren er ikke indstillet korrekt Spark plug faulty Battery low (for electric start) | Tilsæt frisk brændstof Tilsæt motorolie Drej motorkontakten til ON Juster chokeren Rengør eller udskift tændrøret Oplad eller udskift batteriet |
| Ingen strømudgang | Strømafbryder udløst Overbelaste Defekt forbindelse | Nulstil afbryder Reducer belastningen Tjek forbindelser |
| Motoren stopper under drift | Uden for brændstof Lavt olieniveau Overbelaste Beskidt luftfilter | Tilsæt brændstof Tilsæt motorolie Reducer belastningen Rens luftfilteret |
| Motoren kører ujævnt | Gammelt brændstof Beskidt luftfilter Problemer med tændrør | Tøm og fyld op med frisk brændstof Rens luftfilteret Inspicer/rengør/udskift tændrør |
9. Specifikationer
| Specifikation | Værdi |
|---|---|
| Model | TP155001 |
| Mærke | TOTAL |
| Nominel output | 5000W (5.0 kW) |
| Max output | 5500W (5.5 kW) |
| Motortype | 13HP, 4-Stroke, Gasoline |
| Voltage | 230-240V AC |
| Frekvens | 50 Hz |
| Brændstoftankkapacitet | 25 liter |
| Startsystem | Electric Start / Recoil Start |
| Særlige funktioner | AVR, Overload Protection, Low Oil Shutoff |
| Varens vægt | 77 kilo |
| Pakkedimensioner | 70 x 56 x 53 cm |
| Farve | Grøn |
| Materiale | Metal |
10. Garanti og support
For warranty information, please refer to the warranty card included with your product or contact your authorized TOTAL dealer. Keep your purchase receipt as proof of purchase.
For technical support, spare parts, or service inquiries, please contact TOTAL customer service or visit the official TOTAL website. Provide your model number (TP155001) and serial number (if applicable) when contacting support.
You can visit the official Total Store for more information: Total Store on Amazon